A pocket-sized metabolic analyzer for assessment of resting energy expenditure

被引:20
|
作者
Zhao, Di [1 ]
Xian, Xiaojun [1 ]
Terrera, Mirna [1 ]
Krishnan, Ranganath [1 ,3 ]
Miller, Dylan [1 ,2 ]
Bridgeman, Devon [1 ,2 ]
Tao, Kevin [1 ]
Zhang, Lihua [1 ]
Tsow, Francis [1 ]
Forzani, Erica S. [1 ,2 ]
Tao, Nongjian [1 ,3 ]
机构
[1] Arizona State Univ, Ctr Bioelect & Biosensors, Biodesign Inst, Tempe, AZ 85287 USA
[2] Arizona State Univ, Sch Engn Matter Transport & Energy, Tempe, AZ 85287 USA
[3] Arizona State Univ, Sch Elect Comp & Energy Engn, Tempe, AZ 85287 USA
关键词
Resting energy expenditure; Indirect calorimetry; Oxygen consumption; Carbon dioxide production; Weight management; Fitness; CROSS-VALIDATION; EQUATIONS;
D O I
10.1016/j.clnu.2013.06.001
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background & aims: The assessment of metabolic parameters related to energy expenditure has a proven value for weight management; however these measurements remain too difficult and costly for monitoring individuals at home. The objective of this study is to evaluate the accuracy of a new pocket-sized metabolic analyzer device for assessing energy expenditure at rest (REE) and during sedentary activities (EE). The new device performs indirect calorimetry by measuring an individual's oxygen consumption (VO2) and carbon dioxide production (VCO2) rates, which allows the determination of resting- and sedentary activity-related energy expenditure. Methods: VO2 and VCO2 values of 17 volunteer adult subjects were measured during resting and sedentary activities in order to compare the metabolic analyzer with the Douglas bag method. The Douglas bag method is considered the Gold Standard method for indirect calorimetry. Metabolic parameters of VO2, VCO2, and energy expenditure were compared using linear regression analysis, paired t-tests, and Bland-Altman plots. Results: Linear regression analysis of measured VO2 and VCO2 values, as well as calculated energy expenditure assessed with the new analyzer and Douglas bag method, had the following linear regression parameters (linear regression slope LRS0, and R-squared coefficient, r(2)) with p = 0: LRS0 (SD) = 1.00 (0.01), r(2) = 0.9933 for VO2; LRS0 (SD) = 1.00 (0.01), r(2) = 0.9929 for VCO2; and LRS0 (SD) = 1.00 (0.01), r(2) = 0.9942 for energy expenditure. In addition, results from paired t-tests did not show statistical significant difference between the methods with a significance level of alpha = 0.05 for VO2, VCO2, REE, and EE. Furthermore, the Bland-Altman plot for REE showed good agreement between methods with 100% of the results within +/- 2SD, which was equivalent to <= 10% error. Conclusion: The findings demonstrate that the new pocket-sized metabolic analyzer device is accurate for determining VO2, VCO2, and energy expenditure. (C) 2013 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
引用
收藏
页码:341 / 347
页数:7
相关论文
共 50 条
  • [1] Pocket-sized spectroscopy
    不详
    OPTICS AND LASER TECHNOLOGY, 2000, 32 (7-8): : V - V
  • [2] A Pocket-Sized Magazine
    Andriulli, Francesco
    IEEE ANTENNAS AND PROPAGATION MAGAZINE, 2021, 63 (01) : 4 - 4
  • [3] Ultrasound: Reliability of a Pocket-Sized System in the Assessment of Swallowing
    Winiker, Katharina
    Burnip, Emma
    Gozdzikowska, Kristin
    Hernandez, Esther Guiu
    Hammond, Rebecca
    Macrae, Phoebe
    Thomas, Paige
    Huckabee, Maggie-Lee
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2021, 64 (08): : 2928 - 2940
  • [4] Ultrasound: Validity of a Pocket-Sized System in the Assessment of Swallowing
    Winiker, Katharina
    Burnip, Emma
    Gozdzikowska, Kristin
    Guiu Hernandez, Esther
    Hammond, Rebecca
    Macrae, Phoebe
    Huckabee, Maggie-Lee
    DYSPHAGIA, 2021, 36 (06) : 1010 - 1018
  • [5] Ultrasound: Validity of a Pocket-Sized System in the Assessment of Swallowing
    Katharina Winiker
    Emma Burnip
    Kristin Gozdzikowska
    Esther Guiu Hernandez
    Rebecca Hammond
    Phoebe Macrae
    Maggie-Lee Huckabee
    Dysphagia, 2021, 36 : 1010 - 1018
  • [6] Pocket-sized PCR machine
    Ebert, Jessica
    CHEMISTRY WORLD, 2007, 4 (06): : 29 - 29
  • [7] POCKET-SIZED SHORTWAVE RECEIVERS
    BAILEY, H
    RADIO-ELECTRONICS, 1983, 54 (12): : 24 - 24
  • [8] Pocket-sized help for people with dementia
    Collier, Roger
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2011, 183 (03) : E138 - E138
  • [9] Pocket-sized Ultrasound for Physical Diagnosis
    Galen, Benjamin T.
    Schnobrich, Daniel J.
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2015, 30 (07) : 883 - 883
  • [10] Pocket-sized Ultrasound for Physical Diagnosis
    Benjamin T. Galen
    Daniel J. Schnobrich
    Journal of General Internal Medicine, 2015, 30 : 883 - 883