Engineering of diagnostic equatorial port plugs for ITER

被引:3
|
作者
Phillips, G. [1 ]
Krivchenkov, Y. [1 ]
Davis, S. [1 ]
Riddle, K. [1 ]
Parsons, P. [1 ]
Thompson, V. [1 ]
Pampin, R. [1 ]
Balshaw, N. [1 ]
机构
[1] UKAEA, Culham Sci Ctr, Abingdon OX14 3DB, Oxon, England
基金
英国工程与自然科学研究理事会;
关键词
Port plug thermal analysis; Electromagnetic analysis; Neutronics analysis;
D O I
10.1016/j.fusengdes.2009.01.105
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Within the ITER vacuum vessel, there are a significant number of diagnostics, measuring items such as plasma density, temperature and impurities: and providing a visible image of the ITER plasma. Since reliable diagnostic measurements are critical to the successful operation of ITER, robust structural design of the diagnostic supports, or Port Plugs, is also essential. The port plugs are substantial steel structures, mounted in both the equatorial and upper ports on the vacuum vessel. They not only support the diagnostics, but also provide functions of baking, cooling, and neutron shielding. Significant progress has been made in the mechanical design of the port plugs, culminating in the proposal of a new Conceptual design, which uses the lid of the port plug as a structural member. This allows the Port Plug's mass to be more efficiently distributed, providing additional space for diagnostics, and better neutron shielding. A critical aspect of the design has been to provide a suitable interface between the lid and body of the structure which will support all of the structural loads which may be applied to the port plug. The lid also allows easy access to the diagnostic components when maintenance is required. Analyses have been carried out in support of the proposed changes. Structural analysis indicates that the wall thickness of the port plug could be reduced from 130mm to 40mm. Thermal analysis has demonstrated that the cooling and baking requirement for the port plug structure is less challenging than originally thought, and hence could be carried out in a simpler fashion. Neutronics analysis has led to a better understanding of the impact of different shielding materials and cavities through the contents of the port plug, and show that it may be possible to reduce the shielding thickness from 2000mm to 1000 min. Further electromagnetic analysis has been carried out demonstrating that modelling the effect of plasma movement will not affect the resultant loads by more than 20%, and that the originally defined port plug loads were probably conservative. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1510 / 1514
页数:5
相关论文
共 50 条
  • [21] Final design of the generic equatorial port plug structure for ITER diagnostic systems
    Udintsev, V. S.
    Maquet, P.
    Alexandrov, E.
    Casal, N.
    Cuenca, D.
    Drevon, J. -M.
    Feder, R.
    Friconneau, J. P.
    Giacomin, T.
    Guirao, J.
    Iglesias, S.
    Josseaume, F.
    Levesy, B.
    Loesser, D.
    Ordieres, J.
    Quinn, E.
    Pak, S.
    Penot, C.
    Pitcher, C. S.
    Portales, M.
    Proust, M.
    Suarez, A.
    Seyvet, F.
    Tanchuk, V.
    Utin, Y.
    Vacas, C.
    Vasseur, C.
    Walsh, M. J.
    FUSION ENGINEERING AND DESIGN, 2015, 96-97 : 993 - 997
  • [22] ITER diagnostic port plug engineering design analysis in the EU
    Ciattaglia, E.
    Ingesson, L. C.
    Campbell, D.
    Saibene, G.
    Walker, C.
    Doceu, L.
    Dirken, P.
    Petrizzi, L.
    Heidinger, R.
    FUSION ENGINEERING AND DESIGN, 2007, 82 (5-14) : 1231 - 1237
  • [23] Engineering and maintenance studies of the ITER diagnostic upper port plug
    Sato, K.
    Ohmori, J.
    Kondoh, T.
    Hatae, T.
    Kajita, S.
    Ishikawa, M.
    Neyatani, Y.
    Ebisawa, K.
    Kusama, Y.
    FUSION ENGINEERING AND DESIGN, 2009, 84 (7-11) : 1713 - 1715
  • [24] Dose rate analysis for the diagnostic generic equatorial port plug in the ITER port plug test facility
    Liu, Haibo
    Cerisier, Thierry
    Fischer, Ulrich
    Levesy, Bruno
    Romannikov, Alexander
    Serikov, Arkady
    FUSION ENGINEERING AND DESIGN, 2015, 98-99 : 2182 - 2186
  • [25] Electromagnetic studies of effects produced by disruption events inside ITER European diagnostic port plugs
    Junquera, Tomas
    Dieudegard, Florian
    Kochebina, Olga
    Aviles, Alexander
    Marco, Aitor
    Gomez, Celia
    Testoni, Pietro
    Juli, Sandra
    Seyvet, Fabien
    FUSION ENGINEERING AND DESIGN, 2021, 168
  • [26] Monte Carlo radiation shielding and activation analyses for the Diagnostic Equatorial Port Plug in ITER
    Serikov, A.
    Fischer, U.
    Leichtle, D.
    Pitcher, C. S.
    FUSION ENGINEERING AND DESIGN, 2012, 87 (5-6) : 690 - 694
  • [27] Engineering Calculations and Preparation for Manufacturing of ITER Equatorial Port &x0023;11
    Sulyaev, Yu S.
    Alexandrov, E., V
    Burdakov, A., V
    Ivantsivskiy, M., V
    Zemlyanskiy, Yu N.
    Pischinskiy, K., V
    Sharafeeva, S. R.
    Shiyankov, S., V
    Noryshev, E. A.
    Porotnikov, A. B.
    Shoshin, A. A.
    Ivanova, A. N.
    Klimenko, M., V
    Smirnov, A. B.
    Pozhilov, A. A.
    Kirienko, I. D.
    Modestov, V. S.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2020, 48 (06) : 1631 - 1636
  • [28] Preparation For Lower Port Integration Engineering For Iter Diagnostic Systems In Jada
    ITER Organization, Route de Vinon sur Verdon, St Paul-lez-Duranc, France
    不详
    311-0193, Japan
    Plasma Fusion Res., (1-4):
  • [29] Rigid and adjustable fixation of the shielding modules into the ITER port plugs
    Gonzalez, M.
    Guirao, J.
    Vacas, C.
    Rodriguez, E.
    Iglesias, S.
    Udintsev, V.
    Walsh, M.
    Fano, J.
    Ordieres, J.
    Casal, N.
    Giacomin, T.
    Garcia-Ruesgas, L.
    Roces, J.
    FUSION ENGINEERING AND DESIGN, 2017, 123 : 793 - 796
  • [30] Neutronic analysis of the ITER Equatorial Port Plug 1
    Moro, F.
    Esposito, B.
    Brolatti, G.
    Marocco, D.
    Villari, R.
    Salasca, S.
    Cantone, B.
    Dapena-Febrer, M.
    Petrizzi, L.
    FUSION ENGINEERING AND DESIGN, 2012, 87 (7-8) : 1224 - 1229