Rigid and adjustable fixation of the shielding modules into the ITER port plugs

被引:0
|
作者
Gonzalez, M. [1 ]
Guirao, J. [2 ]
Vacas, C. [1 ]
Rodriguez, E. [3 ]
Iglesias, S. [1 ]
Udintsev, V. [2 ]
Walsh, M. [2 ]
Fano, J. [1 ]
Ordieres, J. [1 ]
Casal, N. [2 ]
Giacomin, T. [2 ]
Garcia-Ruesgas, L. [4 ]
Roces, J. [3 ]
机构
[1] Numer Anal Technol SL NATEC, Gijon, Spain
[2] ITER Org, Diagnost Div, TED, Route Vinon Sur Verdon,CS 90 046, F-13067 St Paul Les Durance, France
[3] Univ Oviedo, Dept Construct & Mfg Engn, Gijon, Spain
[4] Univ Seville, Dept Engn Graph, Seville, Spain
关键词
DSM; Equatorial port plug; Finite element; ITER; DIAGNOSTIC SYSTEMS; FINAL DESIGN;
D O I
10.1016/j.fusengdes.2017.04.091
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
During the final design review of Diagnostic Port Plugs, it has been highlighted that the current system of fixation, based on gaps, while it is not harmful for the port plug, it throws large uncertainties over the alignment of the optical systems placed inside the DSMs at the same time that the real mechanical behavior of the assembly is clearly unknown. Because the DSM is not rigidly fixed to the Port Plug structure, the DSM and its internal components suffer, during abnormal events like seismic or electromagnetic disruptions, an important level of amplification on the accelerations induced. This magnification is largely derived from a rattling effect that the DSM is vibrating inside the port plug. This effect produces an increase of the efforts acting on the anchoring components of the port plug at the same time that the final position of the DSM after an abnormal event is unknown and greatly influenced by the manufacturing and assembly tolerances. In order to solve all these issues, a new locking system has been developed based on a rigid configuration. Non -relevant modifications are required in the Port Plug structure or in the DSMs for the implementation of this new system because the interfaces are kept intact. Results based on this new configuration are available and they present an important attenuation of the induced accelerations on components inside the DSMs. In addition, the system permits the individual adjustment of each one of the interfacing component to finally achieve the correct aligned positions. Therefore, this new locking system has been assumed for all IO Diagnostic Port Plugs. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:793 / 796
页数:4
相关论文
共 48 条
  • [1] Nuclear engineering of diagnostic port plugs on ITER
    Pitcher, C. S.
    Barnsley, R.
    Feder, R.
    Hu, Q.
    Loesser, G. D.
    Lyublin, B.
    Padasalagi, S.
    Pak, S.
    Reichle, R.
    Sato, K.
    Udintsev, V. S.
    Walker, C.
    Walsh, M.
    Zhai, Y.
    FUSION ENGINEERING AND DESIGN, 2012, 87 (5-6) : 667 - 674
  • [2] Engineering of diagnostic equatorial port plugs for ITER
    Phillips, G.
    Krivchenkov, Y.
    Davis, S.
    Riddle, K.
    Parsons, P.
    Thompson, V.
    Pampin, R.
    Balshaw, N.
    FUSION ENGINEERING AND DESIGN, 2009, 84 (7-11) : 1510 - 1514
  • [3] Standardized integration of ITER diagnostics Equatorial Port Plugs
    Guirao, J.
    Walsh, M. J.
    Udintsev, V. S.
    Iglesias, S.
    Giacomin, T.
    Bertalot, L.
    Shigin, P.
    Kochergin, M.
    Alexandrov, E.
    Zvonkov, A.
    Ivantsivskiy, M.
    Fang, T.
    Hu, Q.
    Rodriguez, E.
    Ordieres, J.
    Juarez, R.
    Blanchard, A.
    FUSION ENGINEERING AND DESIGN, 2019, 146 : 1548 - 1552
  • [4] Engineering estimates of impurity fluxes on the ITER port plugs
    Kotov, Vladislav
    NUCLEAR FUSION, 2016, 56 (10)
  • [5] Progress on the Integration of ITER Diagnostics Equatorial Port Plugs in Europe
    Salasca, Sophie
    Cantone, Bruno
    Dapena, Miguel
    Joanny, Maryline
    Aumeunier, Marie-Helene
    Travere, Jean-Marcel
    Esposito, Basilio
    Moro, Fabio
    Marocco, Daniele
    Villari, Rosaria
    Brolatti, Giorgio
    Rincon, Esther
    Varela, Paulo
    Nagy, Daniel
    Nemeth, Jozsef
    Zeile, Christian
    Perrollaz, Guillaume
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2012, 40 (03) : 665 - 672
  • [6] CEA engineering studies and integration of the ITER diagnostic port plugs
    Doceul, L.
    Walker, C.
    Ingesson, C.
    Ciattaglia, E.
    Chappuis, P.
    Portafaix, C.
    Salasca, S.
    Thomas, E.
    Tremblay, G.
    Bruyere, C.
    FUSION ENGINEERING AND DESIGN, 2007, 82 (5-14) : 1216 - 1223
  • [7] Progress on the integration of ITER diagnostics equatorial port plugs in Europe
    Salasca, S.
    Cantone, B.
    Dapena, M.
    Joanny, M.
    Aumeunier, M. H.
    Travere, J. M.
    Varela, P.
    Esposito, B.
    Moro, F.
    Marocco, D.
    Villari, R.
    Brolatti, G.
    Nagy, D.
    Nemeth, J.
    Rincon, E.
    Perrollaz, G.
    2011 IEEE/NPSS 24TH SYMPOSIUM ON FUSION ENGINEERING (SOFE), 2011,
  • [8] Shielding analysis for TCP and IVVS bio-shield plugs of ITER
    Baidoo, I. K.
    Wu, Y.
    Song, J.
    Yu, S.
    Jakhar, S.
    Polunovskiy, E.
    Loughlin, M.
    FUSION ENGINEERING AND DESIGN, 2020, 153
  • [9] Thermal and hydraulic analysis of the cooling system for the ITER equatorial port plugs
    Rincon, E.
    Botija, J.
    Garcia, A.
    Medrano, M.
    Sarasola, X.
    Soleto, A.
    Ciattaglia, E.
    Walker, C.
    Doceul, L.
    Balshaw, N.
    Petrizzi, L.
    FUSION ENGINEERING AND DESIGN, 2009, 84 (7-11) : 1611 - 1618
  • [10] Electromagnetic analysis of ITER diagnostic equatorial port plugs during plasma disruptions
    Zhai, Y.
    Feder, R.
    Brooks, A.
    Ulrickson, M.
    Pitcher, C. S.
    Loesser, G. D.
    FUSION ENGINEERING AND DESIGN, 2013, 88 (6-8) : 547 - 550