Rigid and adjustable fixation of the shielding modules into the ITER port plugs

被引:0
|
作者
Gonzalez, M. [1 ]
Guirao, J. [2 ]
Vacas, C. [1 ]
Rodriguez, E. [3 ]
Iglesias, S. [1 ]
Udintsev, V. [2 ]
Walsh, M. [2 ]
Fano, J. [1 ]
Ordieres, J. [1 ]
Casal, N. [2 ]
Giacomin, T. [2 ]
Garcia-Ruesgas, L. [4 ]
Roces, J. [3 ]
机构
[1] Numer Anal Technol SL NATEC, Gijon, Spain
[2] ITER Org, Diagnost Div, TED, Route Vinon Sur Verdon,CS 90 046, F-13067 St Paul Les Durance, France
[3] Univ Oviedo, Dept Construct & Mfg Engn, Gijon, Spain
[4] Univ Seville, Dept Engn Graph, Seville, Spain
关键词
DSM; Equatorial port plug; Finite element; ITER; DIAGNOSTIC SYSTEMS; FINAL DESIGN;
D O I
10.1016/j.fusengdes.2017.04.091
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
During the final design review of Diagnostic Port Plugs, it has been highlighted that the current system of fixation, based on gaps, while it is not harmful for the port plug, it throws large uncertainties over the alignment of the optical systems placed inside the DSMs at the same time that the real mechanical behavior of the assembly is clearly unknown. Because the DSM is not rigidly fixed to the Port Plug structure, the DSM and its internal components suffer, during abnormal events like seismic or electromagnetic disruptions, an important level of amplification on the accelerations induced. This magnification is largely derived from a rattling effect that the DSM is vibrating inside the port plug. This effect produces an increase of the efforts acting on the anchoring components of the port plug at the same time that the final position of the DSM after an abnormal event is unknown and greatly influenced by the manufacturing and assembly tolerances. In order to solve all these issues, a new locking system has been developed based on a rigid configuration. Non -relevant modifications are required in the Port Plug structure or in the DSMs for the implementation of this new system because the interfaces are kept intact. Results based on this new configuration are available and they present an important attenuation of the induced accelerations on components inside the DSMs. In addition, the system permits the individual adjustment of each one of the interfacing component to finally achieve the correct aligned positions. Therefore, this new locking system has been assumed for all IO Diagnostic Port Plugs. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:793 / 796
页数:4
相关论文
共 48 条
  • [21] NEUTRONICS ANALYSIS OF ITER BLANKET MODULES WITH IMPACT ON VACUUM VESSEL SHIELDING
    Sawan, M. E.
    Bohm, T. D.
    Ulrickson, M. A.
    FUSION SCIENCE AND TECHNOLOGY, 2013, 64 (03) : 555 - 562
  • [22] ITER neutronics analysis for the design of diagnostics and port plugs using ATTILA discrete ordinates software
    Feder, Russell
    Youssef, Dr. Mahmoud
    Davis, Ian
    Failla, Greg
    Wareing, Todd
    22ND IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING, 2007, : 139 - +
  • [23] Electromagnetic studies of effects produced by disruption events inside ITER European diagnostic port plugs
    Junquera, Tomas
    Dieudegard, Florian
    Kochebina, Olga
    Aviles, Alexander
    Marco, Aitor
    Gomez, Celia
    Testoni, Pietro
    Juli, Sandra
    Seyvet, Fabien
    FUSION ENGINEERING AND DESIGN, 2021, 168
  • [24] EM Analysis of ITER Diagnostics Upper Port Plugs 14 and 11 During Plasma Disruptions
    Zhai, Yuhu
    Chen, Jingping
    Feder, Russell
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2018, 46 (05) : 1262 - 1267
  • [25] STRESS SHIELDING BY RIGID FIXATION STUDIED IN OSTEOTOMIZED RABBIT TIBIAE
    LAFTMAN, P
    NILSSON, OS
    BROSJO, O
    STROMBERG, L
    ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (06): : 718 - 722
  • [26] Technique for nonfascial fixation of the laparoscopic adjustable gastric band access port
    Wellborn, James Clay, Jr.
    Wellborn, Suzan Hayden
    Wellborn, Trey
    SURGERY FOR OBESITY AND RELATED DISEASES, 2010, 6 (04) : 429 - 433
  • [27] Monte Carlo radiation shielding and activation analyses for the Diagnostic Equatorial Port Plug in ITER
    Serikov, A.
    Fischer, U.
    Leichtle, D.
    Pitcher, C. S.
    FUSION ENGINEERING AND DESIGN, 2012, 87 (5-6) : 690 - 694
  • [28] Access-Port Fixation on the Left Pectoral Fascia in Laparoscopic Adjustable Gastric Banding
    Van Wageningen, B.
    Aarts, E.
    Janssen, I.
    Berends, F.
    OBESITY SURGERY, 2009, 19 (08) : 1059 - 1059
  • [29] Access-Port Fixation on the Left Pectoral Fascia in Laparoscopic Adjustable Gastric Banding
    Bas van Wageningen
    E. O. Aarts
    I. M. C. Janssen
    F. J. Berends
    Obesity Surgery, 2011, 21 : 386 - 390
  • [30] Access-Port Fixation on the Left Pectoral Fascia in Laparoscopic Adjustable Gastric Banding
    van Wageningen, Bas
    Aarts, E. O.
    Janssen, I. M. C.
    Berends, F. J.
    OBESITY SURGERY, 2011, 21 (03) : 386 - 390