Rigid and adjustable fixation of the shielding modules into the ITER port plugs

被引:0
|
作者
Gonzalez, M. [1 ]
Guirao, J. [2 ]
Vacas, C. [1 ]
Rodriguez, E. [3 ]
Iglesias, S. [1 ]
Udintsev, V. [2 ]
Walsh, M. [2 ]
Fano, J. [1 ]
Ordieres, J. [1 ]
Casal, N. [2 ]
Giacomin, T. [2 ]
Garcia-Ruesgas, L. [4 ]
Roces, J. [3 ]
机构
[1] Numer Anal Technol SL NATEC, Gijon, Spain
[2] ITER Org, Diagnost Div, TED, Route Vinon Sur Verdon,CS 90 046, F-13067 St Paul Les Durance, France
[3] Univ Oviedo, Dept Construct & Mfg Engn, Gijon, Spain
[4] Univ Seville, Dept Engn Graph, Seville, Spain
关键词
DSM; Equatorial port plug; Finite element; ITER; DIAGNOSTIC SYSTEMS; FINAL DESIGN;
D O I
10.1016/j.fusengdes.2017.04.091
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
During the final design review of Diagnostic Port Plugs, it has been highlighted that the current system of fixation, based on gaps, while it is not harmful for the port plug, it throws large uncertainties over the alignment of the optical systems placed inside the DSMs at the same time that the real mechanical behavior of the assembly is clearly unknown. Because the DSM is not rigidly fixed to the Port Plug structure, the DSM and its internal components suffer, during abnormal events like seismic or electromagnetic disruptions, an important level of amplification on the accelerations induced. This magnification is largely derived from a rattling effect that the DSM is vibrating inside the port plug. This effect produces an increase of the efforts acting on the anchoring components of the port plug at the same time that the final position of the DSM after an abnormal event is unknown and greatly influenced by the manufacturing and assembly tolerances. In order to solve all these issues, a new locking system has been developed based on a rigid configuration. Non -relevant modifications are required in the Port Plug structure or in the DSMs for the implementation of this new system because the interfaces are kept intact. Results based on this new configuration are available and they present an important attenuation of the induced accelerations on components inside the DSMs. In addition, the system permits the individual adjustment of each one of the interfacing component to finally achieve the correct aligned positions. Therefore, this new locking system has been assumed for all IO Diagnostic Port Plugs. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:793 / 796
页数:4
相关论文
共 48 条
  • [41] Shut-down dose rate analysis for final design of shielding tent in port interspace of ITER UP#18
    Hong, Seonghee
    Kim, Jaemin
    Shim, Heejin
    Cheon, Munseong
    Park, Sunil
    FUSION ENGINEERING AND DESIGN, 2023, 196
  • [42] HISTOMORPHOMETRIC EVALUATION OF STRESS SHIELDING IN MANDIBULAR CONTINUITY DEFECTS TREATED WITH RIGID FIXATION PLATES AND BONE-GRAFTS
    KENNADY, MC
    TUCKER, MR
    LESTER, GE
    BUCKLEY, MJ
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1989, 18 (03) : 170 - 174
  • [43] Computationally efficient methodology of 3D thermal-hydraulic analysis of Diagnostic Shielding Module #2 of ITER Equatorial Port #11
    Pozhilov, A.
    Guirao, J.
    Udintsev, V.
    Lobachev, A.
    Smirnov, A.
    Modestov, V.
    Ivantsivskiy, M.
    Sulyaev, Y.
    FUSION ENGINEERING AND DESIGN, 2023, 192
  • [44] Effects of combined adjustable Halo-pelvic fixation brace on cervical spine alignment in patients with severe rigid spinal deformity
    Rong, Zhigang
    Zhang, Chengmin
    Cheng, Peng
    Dai, Fei
    Chen, Can
    Yu, Xueke
    Xu, Jianzhong
    Luo, Fei
    BMC SURGERY, 2022, 22 (01)
  • [45] Effects of combined adjustable Halo-pelvic fixation brace on cervical spine alignment in patients with severe rigid spinal deformity
    Zhigang Rong
    Chengmin Zhang
    Peng Cheng
    Fei Dai
    Can Chen
    Xueke Yu
    Jianzhong Xu
    Fei Luo
    BMC Surgery, 22
  • [46] Editorial Commentary: All-Inside Anterior Cruciate Ligament Reconstruction Produces Excellent Results: Adjustable Cortical Suspensory Fixation Provides Rigid Tibial Fixation for All Ages
    Schwartzberg, Randy
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2024, 40 (08): : 2289 - 2291
  • [47] Shut-down dose rate analysis for final design of shielding tent in port interspace of ITER UP#18 (vol 196, 114021, 2023)
    Hong, SeongHee
    Kim, Jaemin
    Shim, HeeJin
    Cheon, MunSeong
    Park, Sunil
    FUSION ENGINEERING AND DESIGN, 2024, 206
  • [48] STRESS SHIELDING EFFECT OF RIGID INTERNAL-FIXATION PLATES ON MANDIBULAR BONE-GRAFTS - A PHOTON-ABSORPTION DENSITOMETRY AND QUANTITATIVE COMPUTERIZED TOMOGRAPHIC EVALUATION
    KENNADY, MC
    TUCKER, MR
    LESTER, GE
    BUCKLEY, MJ
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1989, 18 (05) : 307 - 310