Comparison of invasive and non-invasive tonometry in the mouse

被引:44
|
作者
Morris, Christy A.
Crowston, Jonathan G.
Lindsey, James D.
Danias, John
Weinreb, Robert N.
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
[2] Mt Sinai Sch Med, Dept Ophthalmol, New York, NY USA
关键词
glaucoma; intraocular pressure; mouse; tonometer; non-invasive;
D O I
10.1016/j.exer.2005.12.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Assessment of the accuracy of non-invasive rebound tonometry, and comparison with invasive cannulation tonometry. An in vivo calibration technique was devised to improve the accuracy of the rebound tonometer. IOP was then measured in SW mice using both rebound and cannulation tonometry. The ability of the rebound tonometer to accurately measure small IOP reductions after instillation of a topical prostaglandin was also determined. With the rebound method, mid-afternoon IOP in two groups of similar aged SW mice was 15.9 +/- 3.9 mmHg (mean +/- S.D., n = 25) compared to 16.3 +/- 1.2 mmHg (n = 32) using the cannulation technique. This difference was not statistically significant (p = 0.6). For serial measurements using both techniques in the same eyes of a third group of SW mice (n = 14), mean IOP was 15.0 +/- 3.9 mmHg for rebound tonometry but only 13.4 +/- 2.3 mmHg for subsequent cannulation tonometry. This effect was subsequently shown to be a consequence of the rebound tonometry, as multiple rebound measurements induced a statistically significant reduction in IOP. The average IOP reduction observed 2 hr after a single application of topical latanoprost (200 ng) was 2.8 +/- 1.3 mmHg (p < 0.001) and 2.4 +/- 4.7 mmHg (p = 0.03) with cannulation and rebound tonometers, respectively. These differences were not significantly different (p = 0.8). In vivo calibration of the rebound tonometer increased measurement accuracy and provided IOP values within the physiological range that agreed closely with the IOP measured by cannulation tonometry. However, IOP measurement with the rebound tonometer had larger variability compared with the cannulation method. Repeat IOP measurements with the rebound tonometer led to a reduction in IOP. The rebound tonometer was sufficiently sensitive to detect a 2-3 mmHg reduction in IOP following application of topical latanoprost. Despite these limitations, the rebound tonometer has a significant advantage over cannulation tonometry in that it permits longitudinal IOP measurement in conscious mice. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1094 / 1099
页数:6
相关论文
共 50 条
  • [41] Approaches for non-invasive assessment of endothelial function: focus on peripheral arterial tonometry
    Kandhai-Ragunath, J. J.
    Jorstad, H. T.
    de Man, F. H. A. F.
    Peters, R. J. G.
    von Birgelen, C.
    NETHERLANDS HEART JOURNAL, 2013, 21 (05) : 214 - 218
  • [42] NON-INVASIVE EVALUATION OF ENDOTHELIAL FUNCTION IN HEALTHY INDIAN SUBJECTS USING TONOMETRY
    Reddy, Chinthaparthi P.
    Naidu, Mur
    JOURNAL OF CLINICAL PHARMACOLOGY, 2009, 49 (09): : 1103 - 1103
  • [43] Rebound tonometry: new opportunities and limitations of non-invasive determination of intraocular pressure
    Cervino, A.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (12) : 1444 - 1446
  • [44] Approaches for non-invasive assessment of endothelial function: focus on peripheral arterial tonometry
    J. J. Kandhai-Ragunath
    H. T. Jørstad
    F. H. A. F. de Man
    R. J. G. Peters
    C. von Birgelen
    Netherlands Heart Journal, 2013, 21 : 214 - 218
  • [45] PROS AND CONS - NON-INVASIVE OR INVASIVE DIAGNOSTICS IN CARDIOLOGY - ARGUMENTS FOR A NON-INVASIVE PROCEDURE
    BLOMER, H
    INTERNIST, 1981, 22 (11): : 664 - 671
  • [46] Classification of Hypopneas as Obstructive or Non-Obstructive: A Comparison of Invasive and Non-Invasive Methodologies
    Tolbert, T.
    Sands, S. A.
    Parekh, A.
    Mooney, A. M.
    Ayappa, I. A.
    Rapoport, D. M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [47] TISSUE TONOMETRY - A NON-INVASIVE MEANS OF QUANTIFYING TISSUE CHANGES IN LYMPHOEDEMATOUS EXTREMITIES
    PILLER, NB
    CLODIUS, L
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1982, 9 (05) : 535 - 536
  • [48] CONTROVERSIAL STANDPOINTS IN CARDIOLOGY - NON-INVASIVE OR INVASIVE DIAGNOSTICS - CORONARY INSUFFICIENCY - NON-INVASIVE
    BLOMER, H
    ZEITSCHRIFT FUR KARDIOLOGIE, 1981, 70 (04): : 328 - 328
  • [49] WHEN NON-INVASIVE MEANS INVASIVE
    SPODICK, DH
    ANNALS OF INTERNAL MEDICINE, 1980, 92 (05) : 722 - 722
  • [50] Analysis of Invasive and Non-Invasive Meningiomas