Comparison of invasive and non-invasive tonometry in the mouse

被引:44
|
作者
Morris, Christy A.
Crowston, Jonathan G.
Lindsey, James D.
Danias, John
Weinreb, Robert N.
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
[2] Mt Sinai Sch Med, Dept Ophthalmol, New York, NY USA
关键词
glaucoma; intraocular pressure; mouse; tonometer; non-invasive;
D O I
10.1016/j.exer.2005.12.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Assessment of the accuracy of non-invasive rebound tonometry, and comparison with invasive cannulation tonometry. An in vivo calibration technique was devised to improve the accuracy of the rebound tonometer. IOP was then measured in SW mice using both rebound and cannulation tonometry. The ability of the rebound tonometer to accurately measure small IOP reductions after instillation of a topical prostaglandin was also determined. With the rebound method, mid-afternoon IOP in two groups of similar aged SW mice was 15.9 +/- 3.9 mmHg (mean +/- S.D., n = 25) compared to 16.3 +/- 1.2 mmHg (n = 32) using the cannulation technique. This difference was not statistically significant (p = 0.6). For serial measurements using both techniques in the same eyes of a third group of SW mice (n = 14), mean IOP was 15.0 +/- 3.9 mmHg for rebound tonometry but only 13.4 +/- 2.3 mmHg for subsequent cannulation tonometry. This effect was subsequently shown to be a consequence of the rebound tonometry, as multiple rebound measurements induced a statistically significant reduction in IOP. The average IOP reduction observed 2 hr after a single application of topical latanoprost (200 ng) was 2.8 +/- 1.3 mmHg (p < 0.001) and 2.4 +/- 4.7 mmHg (p = 0.03) with cannulation and rebound tonometers, respectively. These differences were not significantly different (p = 0.8). In vivo calibration of the rebound tonometer increased measurement accuracy and provided IOP values within the physiological range that agreed closely with the IOP measured by cannulation tonometry. However, IOP measurement with the rebound tonometer had larger variability compared with the cannulation method. Repeat IOP measurements with the rebound tonometer led to a reduction in IOP. The rebound tonometer was sufficiently sensitive to detect a 2-3 mmHg reduction in IOP following application of topical latanoprost. Despite these limitations, the rebound tonometer has a significant advantage over cannulation tonometry in that it permits longitudinal IOP measurement in conscious mice. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1094 / 1099
页数:6
相关论文
共 50 条
  • [1] Non-invasive tonometry in the mouse
    Ahmed, E
    Ma, J
    Rigas, I
    Hafezi-Moghadam, N
    Illiaki, E
    Gragoudas, ES
    Miller, JW
    Adamis, AP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U230 - U230
  • [2] Predictability and limitations of non-invasive murine tonometry: Comparison of two devices
    Filippopoulos, Theodoros
    Matsubara, Akihisa
    Danias, John
    Huang, Wei
    Dobberfuhl, Adam
    Ren, Lizhen
    Mittag, Thomas
    Miller, Joan W.
    Grosskreutz, Cynthia L.
    EXPERIMENTAL EYE RESEARCH, 2006, 83 (01) : 194 - 201
  • [3] NON-INVASIVE OCULAR TONOMETRY USING LDV
    CLOUD, GL
    KANISTANAUX, DC
    HAMMELINK, J
    EXPERIMENTAL MECHANICS, 1982, 22 (05) : N40 - N40
  • [4] A COMPARISON OF INVASIVE AND NON-INVASIVE ELECTROCOCHLEOGRAPHY
    STEVENS, JC
    JEFFRIES, DD
    BUFFIN, JT
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1983, 4 (01): : 100 - 100
  • [5] Comparison of intraocular tonometry using three different non-invasive tonometers in children
    Lasseck, Julia
    Jehle, Thomas
    Feltgen, Nicolas
    Lagreze, Wolf Alexander
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 246 (10) : 1463 - 1466
  • [6] Comparison of intraocular tonometry using three different non-invasive tonometers in children
    Julia Lasseck
    Thomas Jehle
    Nicolas Feltgen
    Wolf Alexander Lagrèze
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2008, 246 : 1463 - 1466
  • [7] Comparison of repeatability of non-invasive and invasive urodynamics
    van Mastrigt, R
    Chung, JWNCHF
    NEUROUROLOGY AND URODYNAMICS, 2004, 23 (04) : 317 - 321
  • [8] OF HOW NON-INVASIVE IS NON-INVASIVE
    BURCH, GE
    AMERICAN HEART JOURNAL, 1978, 96 (01) : 130 - 130
  • [9] DEVELOPMENT OF A NON-INVASIVE CALIBRATION METHOD FOR OCULAR TACTILE TONOMETRY
    Enikov, Eniko T.
    Polyvas, Peter P.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 3A, 2014,
  • [10] Comparison of invasive and non-invasive intracranial pressure monitoring
    Hamarat, Y.
    Deimantavicius, M.
    Zakelis, R.
    Bartusis, L.
    Preiksaitis, A.
    Ragauska, A.
    EUROPEAN JOURNAL OF NEUROLOGY, 2018, 25 : 60 - 60