Cerebral oxygenation and circulatory parameters during pressure-controlled vs volume-targeted mechanical ventilation in extremely preterm infants

被引:10
|
作者
Bugiera, Michalina [1 ]
Szczapa, Tomasz [1 ]
Sowinska, Anna [2 ]
Roehr, Charles Christoph Roehr [3 ]
Szymankiewicz-Breborowicz, Marta [1 ]
机构
[1] Poznan Univ Med Sci, Dept Neonatol, Poznan, Poland
[2] Poznan Univ Med Sci, Dept Comp Sci & Stat, Poznan, Poland
[3] Oxford Univ Hosp NHS Fdn Trust, John Radcliffe Hosp, Newborn Serv, Oxford, England
来源
关键词
respiratory distress syndrome; volume-targeted ventilation; preterm infant; cerebral oxygenation; electrical cardiometry; NEAR-INFRARED SPECTROSCOPY; CARBON-DIOXIDE; BLOOD-FLOW; OUTPUT; STRATEGIES; EXTRACTION; IMPACT;
D O I
10.17219/acem/128198
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background. Respiratory distress syndrome (RDS) is the most common cause of respiratory failure of infants born prematurely with very low birth weight (VLBW). Essential elements of RDS management include ventilatory support and endotracheal administration of a surfactant. Objectives. To assess the effect of volume-targeted compared to pressure-controlled mechanical ventilation (MV) on circulatory parameters and cerebral oxygenation StO(2) in extremely preterm infants. Material and methods. This prospective, cross-over trial enrolled neonates born before 28 weeks of gestation. The patients were ventilated for 3 h in pressure-controlled assist-control (PC-AC) mode, followed by 3 h of volume-guarantee assist-control ventilation (VG-AC). Pulse oximetry (saturation (SpO(2)) and heart rate (HR)), near-infrared spectroscopy (NIRS), StO(2), and electrical cardiometry (EC) were used in monitoring of the patients. Results. Twenty preterm infants with a mean gestational age of 26 weeks were studied. The patients' mean postnatal age was 7.7 days. The SpO(2) values and HR were comparable during PC-AC and VG-AC. The mean values of peak inspiratory pressure (PIP), mean airway pressure (MAP) and expiratory tidal volume (VTE) were lower, while the respiratory rate (RR) was higher during PC-VG. There were no significant differences in the mean values of StO(2), but based on a comparison of the standard deviations (SD) the StO(2) variability was significantly lower during VG-AC. The circulatory parameters were comparable. Conclusions. The StO(2) is more stable during VG than PC ventilation. These findings support the use of VG mode in premature infants.
引用
收藏
页码:1325 / 1329
页数:5
相关论文
共 50 条
  • [41] Comparisons of Mechanical Power and Respiratory Mechanics in Pressure-Controlled Ventilation and Volume-Controlled Ventilation during Laparoscopic Cholecystectomy in Elderly Patients
    Jo, Youn Yi
    Chang, Young Jin
    Lee, Dongchul
    Kim, Yong Beom
    Jung, Junsu
    Kwak, Hyun Jeong
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (02):
  • [42] Implementing Volume-targeted Ventilation to Decrease Hypocarbia in Extremely Low Birth Weight Infants during the First Week of Life: A Quality Improvement Project
    Akpan, Uduak S.
    Patel, Sunny
    Driver, Paige
    Tumin, Dmitry
    PEDIATRIC QUALITY & SAFETY, 2021, 6 (03)
  • [43] Effects of positive end-expiratory pressure on ventilatory and oxygenation parameters during pressure-controlled one-lung ventilation
    Sentürk, NM
    Dilek, A
    Çamci, E
    Sentürk, E
    Orhan, M
    Tugrul, M
    Pembeci, K
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2005, 19 (01) : 71 - 75
  • [44] Volume-controlled versus pressure-controlled ventilation-volume guaranteed mode during one-lung ventilation
    Song, Seok Young
    Jung, Jin Yong
    Cho, Min-Su
    Kim, Jong Hae
    Ryu, Tae Ha
    Kim, Bong Il
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2014, 67 (04) : 258 - 263
  • [45] Randomised Trial of Volume-Targeted Ventilation versus Pressure-Limited Ventilation in Acute Respiratory Failure in Prematurely Born Infants
    Chowdhury, Olie
    Patel, Deena-Shefali
    Hannam, Simon
    Lee, Silke
    Rafferty, Gerrard F.
    Peacock, Janet L.
    Greenough, Anne
    NEONATOLOGY, 2013, 104 (04) : 290 - 294
  • [46] Pressure-controlled versus volume-controlled ventilation during one-lung ventilation for thoracic surgery
    Carmen Unzueta, M.
    Ignacic Casas, J.
    Victoria Moral, M.
    ANESTHESIA AND ANALGESIA, 2007, 104 (05): : 1029 - 1033
  • [47] Comparison of pressure vs. volume controlled ventilation on oxygenation parameters of obese patients undergoing laparoscopic cholecystectomy
    Movassagi, Reza
    Montazer, Majid
    Mahmoodpoor, Ata
    Fattahi, Vahid
    Iranpour, Afshin
    Sanaie, Sarvin
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2017, 33 (05) : 1117 - 1122
  • [48] A comparison between volume-controlled ventilation and pressure-controlled ventilation in providing better oxygenation in obese patients undergoing laparoscopic cholecystectomy
    Gupta, Sampa Dutta
    Kundu, Sudeshna Bhar
    Ghose, Tapas
    Maji, Sunanda
    Mitra, Koel
    Mukherjee, Maitreyee
    Mandal, Sripurna
    Sarbapalli, Debabrata
    Bhattacharya, Sulagna
    Bhattacharya, Saikat
    INDIAN JOURNAL OF ANAESTHESIA, 2012, 56 (03) : 276 - 282
  • [49] Volume guarantee pressure support ventilation in extremely preterm infants and neurodevelopmental outcome at 18 months
    A Razak
    Journal of Perinatology, 2015, 35 : 974 - 974
  • [50] Breathing circuit compliance and accuracy of displayed tidal volume during pressure-controlled ventilation of infants: A quality improvement project
    Glenski, Todd A.
    Diehl, Carrie
    Clopton, Rachel G.
    Friesen, Robert H.
    PEDIATRIC ANESTHESIA, 2017, 27 (09) : 935 - 941