Effects of positive end-expiratory pressure on ventilatory and oxygenation parameters during pressure-controlled one-lung ventilation

被引:57
|
作者
Sentürk, NM [1 ]
Dilek, A [1 ]
Çamci, E [1 ]
Sentürk, E [1 ]
Orhan, M [1 ]
Tugrul, M [1 ]
Pembeci, K [1 ]
机构
[1] Istanbul Univ, Istanbul Fac Med, Dept Anesthesiol, TR-34390 Istanbul, Turkey
关键词
ventilation; one-lung ventilation; pressure controlled; positive end-expiratory pressure; oxygenation;
D O I
10.1053/j.jvca.2004.11.013
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objectives: The purpose of this study was to investigate the effects of PEEP on oxygenation and airway pressures during PCV-OLV. Design: Randomized, crossover, clinical study. Setting: University hospital. Participants: Twenty-five patients undergoing thoracotomy. Interventions: During the first 5 minutes of OLV, all patients were ventilated with VCV (PEEP: 0) (VCV-ZEEP). Afterward, ventilation was changed to PCV with PEEP: 0 (PCV-ZEEP) or PEEP: 4 cmH(2)O (PCV-PEEP) for 20 minutes. In the following 20 minutes, PCV-PEEP and PCV-ZEEP were applied in reverse sequence. Measurements and Main Results: At the end of VCV-ZEEP airway pressures (peak airway pressure, plateau airway pressure, mean airway pressure, and pause airway pressure) were recorded. At the end of PCV-PEEP and PCV-ZEEP air-way pressures, PaO2 and Qs/Qt were recorded. Ppeak and Pplat were significantly lower with PCV-PEEP compared with VCV-ZEEP (eg, Ppeak: 33.4 +/- 4.2,28.3 +/- 4.1, and 28.9 +/- 3.7 cmH(2)O in VCV-ZEEP, PCV-ZEEP, and PCV-PEEP, respectively; p < 0.05 for PCV-ZEEP v VCV-ZEEP and PCV-PEEP v VCV-ZEEP). PCV-PEEP was associated with an increased PaO2 (230.3 +/- 69.8 v 189.0 +/- 54.8 mmHg, p < 0.05) and decreased Qs/Qt (33.4% +/- 7.3% v 38.4% +/- 5.7%, p < 0.05) compared with PCV-ZEEP (mean SD). Eighty-eight percent of the patients have benefited from PEEP. Conclusion: During OLV, PCV with a low level of PEEP leads to improved oxygenation with lower airway pressures. (C) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:71 / 75
页数:5
相关论文
共 50 条
  • [1] Positive end-expiratory pressure in pressure-controlled ventilation improves ventilatory and oxygenation parameters during laparoscopic cholecystectomy
    Ji Young Kim
    Cheung Soo Shin
    Hong Soon Kim
    Wol Sun Jung
    Hyun Jeong Kwak
    Surgical Endoscopy, 2010, 24 : 1099 - 1103
  • [2] Positive end-expiratory pressure in pressure-controlled ventilation improves ventilatory and oxygenation parameters during laparoscopic cholecystectomy
    Kim, Ji Young
    Shin, Cheung Soo
    Kim, Hong Soon
    Jung, Wol Sun
    Kwak, Hyun Jeong
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2010, 24 (05): : 1099 - 1103
  • [3] The effect of timing of application of positive end-expiratory pressure on oxygenation during one-lung ventilation
    Ren, Y.
    Peng, Z. L.
    Xue, Q. S.
    Yu, B. W.
    ANAESTHESIA AND INTENSIVE CARE, 2008, 36 (04) : 544 - 548
  • [4] Effects of Alveolar Recruitment and Positive End-Expiratory Pressure on Oxygenation during One-Lung Ventilation in the Supine Position
    Choi, Yong Seon
    Bae, Mi Kyung
    Kim, Shin Hyung
    Park, Ji-Eun
    Kim, Soo Young
    Oh, Young Jun
    YONSEI MEDICAL JOURNAL, 2015, 56 (05) : 1421 - 1427
  • [5] Prospective, randomized, controlled evaluation of the preventive effects of positive end-expiratory pressure on patient oxygenation during one-lung ventilation
    Mascotto, G
    Bizzarri, M
    Messina, M
    Cerchierini, E
    Torri, G
    Carozzo, A
    Casati, A
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2003, 20 (09) : 704 - 710
  • [6] Influence of tidal volume and positive end-expiratory pressure on ventilation distribution and oxygenation during one-lung ventilation
    Zhao, Zhanqi
    Wang, Wei
    Zhang, Zuojing
    Xu, Meiying
    Frerichs, Inez
    Wu, Jingxiang
    Moeller, Knut
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (03)
  • [7] Relation of the static compliance curve and positive end-expiratory pressure to oxygenation during one-lung ventilation
    Slinger, PD
    Kruger, M
    McRae, K
    Winton, T
    ANESTHESIOLOGY, 2001, 95 (05) : 1096 - 1102
  • [8] Effects of different positive end-expiratory pressure titrating strategies on oxygenation and respiratory mechanics during one-lung ventilation: a randomized controlled trial
    Xu, Dian
    Wei, Wei
    Chen, Lianhua
    Li, Shitong
    Lian, Ming
    ANNALS OF PALLIATIVE MEDICINE, 2021, 10 (02) : 1133 - 1144
  • [9] Effects of Positive End-Expiratory Pressure on Pulmonary Oxygenation and Biventricular Function during One-Lung Ventilation: A Randomized Crossover Study
    Kim, Namo
    Lee, Su Hyun
    Choi, Kwan Woong
    Lee, Haeyeon
    Oh, Young Jun
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (05)
  • [10] The effect of positive end-expiratory pressure and continuous positive airway pressure on the oxygenation and shunt fraction during one-lung ventilation with propofol anesthesia
    Fujiwara, M
    Abe, K
    Mashimo, T
    JOURNAL OF CLINICAL ANESTHESIA, 2001, 13 (07) : 473 - 477