Relation of the static compliance curve and positive end-expiratory pressure to oxygenation during one-lung ventilation

被引:102
|
作者
Slinger, PD
Kruger, M
McRae, K
Winton, T
机构
[1] Univ Hlth Network Mt Sinai Hosp, Dept Anesthesia, Toronto, ON, Canada
[2] Univ Alberta, Dept Surg, Edmonton, AB, Canada
关键词
D O I
10.1097/00000542-200111000-00012
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Positive end-expiratory pressure (PEEP) is commonly applied to the ventilated lung to try to improve oxygenation during one-lung ventilation but is an unreliable therapy and occasionally causes arterial oxygen partial pressure (Pao,) to decrease further. The current study examined whether the effects of PEEP on oxygenation depend on the static compliance curve of the lung to which it is applied. Methods: Forty-two adults undergoing thoracic surgery were studied during stable, open-chest, one-lung ventilation. Arterial blood gasses were measured during two-lung ventilation and one-lung ventilation before, during, and after the application of 5 cm H2O PEEP to the ventilated lung. The plateau end-expiratory pressure and static compliance curve of the ventilated lung were measured with and without applied PEEP, and the lower inflection point was determined from the compliance curve. Results: Mean (+/- SD) Pao, values, with a fraction of inspired oxygen of 1.0, were not different during one-lung ventilation before (192 +/- 91 mmHg), during (190 +/- 90), or after (205 +/- 79) the addition of 5 cm H2O PEEP. The mean plateau end-expiratory pressure increased from 4.2 to 6.8 cm H2O with the application of 5 cm H2O PEEP and decreased to 4.5 cm H2O when 5 cm H2O PEEP was removed. Six patients showed a clinically useful (> 20%) increase in Pao(2) with 5 cm H2O PEEP, and nine patients had a greater than 20% decrease in Pao2. The change in Pao(2) with the application of 5 CM H2O PEEP correlated in an inverse fashion with the change in the gradient between the end-expiratory pressure and the pressure at the lower inflection point (r = 0.76). The subgroup of patients with a Pao, during two-lung ventilation that was less than the mean (365 mmHg) and an end-expiratory pressure during one-lung ventilation without applied PEEP less than the mean were more likely to have an increase in Pao, when 5 cm H2O PEEP was applied. Conclusions: The effects of the application of external 5 cm H2O PEEP on oxygenation during one-lung ventilation correspond to individual changes in the relation between the plateau end-expiratory pressure and the inflection point of the static compliance curve. When the application of PEEP causes the end-expiratory pressure to Increase from a low level toward the Inflection point, oxygenation is likely to improve. Conversely, if the addition of PEEP causes an increased inflation of the ventilated lung that raises the equilibrium end-expiratory pressure beyond the inflection point, oxygenation Is likely to deteriorate.
引用
收藏
页码:1096 / 1102
页数:7
相关论文
共 50 条
  • [1] The effect of timing of application of positive end-expiratory pressure on oxygenation during one-lung ventilation
    Ren, Y.
    Peng, Z. L.
    Xue, Q. S.
    Yu, B. W.
    ANAESTHESIA AND INTENSIVE CARE, 2008, 36 (04) : 544 - 548
  • [2] The relation of the static compliance curve and peep to oxygenation during one-lung ventilation
    Slinger, PD
    Kruger, M
    McRae, K
    Winton, T
    ANESTHESIOLOGY, 1999, 91 (3A) : U518 - U518
  • [3] Influence of tidal volume and positive end-expiratory pressure on ventilation distribution and oxygenation during one-lung ventilation
    Zhao, Zhanqi
    Wang, Wei
    Zhang, Zuojing
    Xu, Meiying
    Frerichs, Inez
    Wu, Jingxiang
    Moeller, Knut
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (03)
  • [4] Effects of positive end-expiratory pressure on ventilatory and oxygenation parameters during pressure-controlled one-lung ventilation
    Sentürk, NM
    Dilek, A
    Çamci, E
    Sentürk, E
    Orhan, M
    Tugrul, M
    Pembeci, K
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2005, 19 (01) : 71 - 75
  • [5] Effects of Alveolar Recruitment and Positive End-Expiratory Pressure on Oxygenation during One-Lung Ventilation in the Supine Position
    Choi, Yong Seon
    Bae, Mi Kyung
    Kim, Shin Hyung
    Park, Ji-Eun
    Kim, Soo Young
    Oh, Young Jun
    YONSEI MEDICAL JOURNAL, 2015, 56 (05) : 1421 - 1427
  • [6] Positive end-expiratory pressure during one-lung ventilation improves oxygenation in patients with low arterial oxygen tensions
    Cohen, E
    Eisenkraft, JB
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1996, 10 (05) : 578 - 582
  • [7] The effect of positive end-expiratory pressure and continuous positive airway pressure on the oxygenation and shunt fraction during one-lung ventilation with propofol anesthesia
    Fujiwara, M
    Abe, K
    Mashimo, T
    JOURNAL OF CLINICAL ANESTHESIA, 2001, 13 (07) : 473 - 477
  • [8] Reducing tidal volume and increasing positive end-expiratory pressure with constant plateau pressure during one-lung ventilation: effect on oxygenation
    Roze, H.
    Lafargue, M.
    Perez, P.
    Tafer, N.
    Batoz, H.
    Germain, C.
    Janvier, G.
    Ouattara, A.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (06) : 1022 - 1027
  • [9] Prospective, randomized, controlled evaluation of the preventive effects of positive end-expiratory pressure on patient oxygenation during one-lung ventilation
    Mascotto, G
    Bizzarri, M
    Messina, M
    Cerchierini, E
    Torri, G
    Carozzo, A
    Casati, A
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2003, 20 (09) : 704 - 710
  • [10] Effects of Positive End-Expiratory Pressure on Pulmonary Oxygenation and Biventricular Function during One-Lung Ventilation: A Randomized Crossover Study
    Kim, Namo
    Lee, Su Hyun
    Choi, Kwan Woong
    Lee, Haeyeon
    Oh, Young Jun
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (05)