Relation of the static compliance curve and positive end-expiratory pressure to oxygenation during one-lung ventilation

被引:102
|
作者
Slinger, PD
Kruger, M
McRae, K
Winton, T
机构
[1] Univ Hlth Network Mt Sinai Hosp, Dept Anesthesia, Toronto, ON, Canada
[2] Univ Alberta, Dept Surg, Edmonton, AB, Canada
关键词
D O I
10.1097/00000542-200111000-00012
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Positive end-expiratory pressure (PEEP) is commonly applied to the ventilated lung to try to improve oxygenation during one-lung ventilation but is an unreliable therapy and occasionally causes arterial oxygen partial pressure (Pao,) to decrease further. The current study examined whether the effects of PEEP on oxygenation depend on the static compliance curve of the lung to which it is applied. Methods: Forty-two adults undergoing thoracic surgery were studied during stable, open-chest, one-lung ventilation. Arterial blood gasses were measured during two-lung ventilation and one-lung ventilation before, during, and after the application of 5 cm H2O PEEP to the ventilated lung. The plateau end-expiratory pressure and static compliance curve of the ventilated lung were measured with and without applied PEEP, and the lower inflection point was determined from the compliance curve. Results: Mean (+/- SD) Pao, values, with a fraction of inspired oxygen of 1.0, were not different during one-lung ventilation before (192 +/- 91 mmHg), during (190 +/- 90), or after (205 +/- 79) the addition of 5 cm H2O PEEP. The mean plateau end-expiratory pressure increased from 4.2 to 6.8 cm H2O with the application of 5 cm H2O PEEP and decreased to 4.5 cm H2O when 5 cm H2O PEEP was removed. Six patients showed a clinically useful (> 20%) increase in Pao(2) with 5 cm H2O PEEP, and nine patients had a greater than 20% decrease in Pao2. The change in Pao(2) with the application of 5 CM H2O PEEP correlated in an inverse fashion with the change in the gradient between the end-expiratory pressure and the pressure at the lower inflection point (r = 0.76). The subgroup of patients with a Pao, during two-lung ventilation that was less than the mean (365 mmHg) and an end-expiratory pressure during one-lung ventilation without applied PEEP less than the mean were more likely to have an increase in Pao, when 5 cm H2O PEEP was applied. Conclusions: The effects of the application of external 5 cm H2O PEEP on oxygenation during one-lung ventilation correspond to individual changes in the relation between the plateau end-expiratory pressure and the inflection point of the static compliance curve. When the application of PEEP causes the end-expiratory pressure to Increase from a low level toward the Inflection point, oxygenation is likely to improve. Conversely, if the addition of PEEP causes an increased inflation of the ventilated lung that raises the equilibrium end-expiratory pressure beyond the inflection point, oxygenation Is likely to deteriorate.
引用
收藏
页码:1096 / 1102
页数:7
相关论文
共 50 条
  • [21] Lung-protective strategy during one-lung ventilation: current and future approaches to quantify the role of positive end-expiratory pressure
    Gentili, Andrea
    MINERVA ANESTESIOLOGICA, 2024, 90 (1-2) : 3 - 5
  • [22] The effect of positive end expiratory pressure on the respiratory profile during one-lung ventilation for thoracotomy
    Leong, L. M. C.
    Chatterjee, S.
    Ga, F.
    ANAESTHESIA, 2007, 62 (01) : 23 - 26
  • [23] The influence of positive end-expiratory pressure (PEEP) in predicting fluid responsiveness in patients undergoing one-lung ventilation
    Jun, In-Jung
    Chung, Mi Hwa
    Kim, Jung Eun
    Lee, Hye Sun
    Son, Jung Mo
    Choi, Eun Mi
    INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2021, 18 (12): : 2589 - 2598
  • [24] ONE-LUNG VENTILATION - THE EFFECTS OF POSITIVE END EXPIRATORY PRESSURE TO THE NONDEPENDENT AND DEPENDENT LUNG
    OBARA, H
    TANAKA, O
    HOSHINO, Y
    KAETSU, H
    MAEKAWA, N
    IWAI, S
    ANAESTHESIA, 1986, 41 (10) : 1007 - 1010
  • [25] Auto-positive end-expiratory pressure during one-lung ventilation using a double-lumen endobronchial tube
    Yokota, K
    Toriumi, T
    Sari, A
    Endou, S
    Mihira, M
    ANESTHESIA AND ANALGESIA, 1996, 82 (05): : 1007 - 1010
  • [26] Effects of alveolar recruitment maneuver on end-expiratory lung volume during one-lung ventilation
    Yutaka Miura
    Seiji Ishikawa
    Koichi Nakazawa
    Kenichi Okubo
    Koshi Makita
    Journal of Anesthesia, 2020, 34 : 224 - 231
  • [27] Effects of alveolar recruitment maneuver on end-expiratory lung volume during one-lung ventilation
    Miura, Yutaka
    Ishikawa, Seiji
    Nakazawa, Koichi
    Okubo, Kenichi
    Makita, Koshi
    JOURNAL OF ANESTHESIA, 2020, 34 (02) : 224 - 231
  • [28] Effects of Positive End-Expiratory Pressure on Intraocular Pressure during One-Lung Ventilation in the Lateral Decubitus Position-A Prospective Randomized Trial
    Kim, Yong Shin
    Seo, Kwon Hui
    Jeon, Yeon Soo
    In, Jang Hyeok
    Jung, Hong Soo
    Park, Yoo Jung
    Jun, Eun Hwa
    Yu, Eunju
    MEDICINA-LITHUANIA, 2022, 58 (07):
  • [29] Heterogeneity in ventilation during positive end-expiratory pressure
    Mukesh Tripathi
    Mamta Pandey
    Critical Care, 14 (4):
  • [30] One-lung ventilation with high tidal volumes and zero positive end-expiratory pressure is injurious in the isolated rabbit lung model
    de Abreu, MG
    Heintz, M
    Heller, A
    Széchényi, R
    Albrecht, DM
    Koch, T
    ANESTHESIA AND ANALGESIA, 2003, 96 (01): : 220 - 228