Does flexion of the femoral implant in total knee arthroplasty increase knee flexion: A randomised controlled trial

被引:25
|
作者
Murphy, Michael [1 ]
Journeaux, Simon [2 ]
Hides, Julie [3 ]
Russell, Trevor [1 ]
机构
[1] Mater Hlth Serv, Mater Med Res Inst, South Brisbane, Qld 4101, Australia
[2] Univ Queensland, Sch Hlth & Rehabil Sci, St Lucia, Qld 4076, Australia
[3] Australian Catholic Univ, Fac Hlth Sci, Banyo, Qld 4014, Australia
来源
KNEE | 2014年 / 21卷 / 01期
关键词
Total knee arthroplasty; Implant flexion; Knee flexion; Randomised controlled trial; POSTERIOR CONDYLAR OFFSET; FUNCTIONAL-ACTIVITIES; RANGE; MOTION; JOINT; REPLACEMENT; KINEMATICS; COMPONENT; OUTCOMES; HIP;
D O I
10.1016/j.knee.2012.10.028
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Prosthetic and operative modifications in total knee arthroplasty (TKA) have been proposed to maximise post-operative knee flexion as it is essential in routine functional activities. Methods: We performed a double blind randomised controlled trial to compare clinical outcomes of primary cruciate-retaining TKA for osteoarthritis with the femoral component implanted in either 4 flexion in the sagittal plane (F) or in a neutral position (C). The primary outcome of knee flexion and secondary outcomes knee extension, quadriceps strength, WOMAC, SF-12v2, timed stand test, stair climb test and satisfaction were assessed at 1 year. Knee flexion and extension were also assessed intra-operatively. Implant flexion was measured from true lateral radiographs. Results: Thirty-nine participants (40 knees) were recruited, 20 knees per group. Three subjects from the control group and two from the flexed group were lost to 1 year follow-up but numbers were sufficient to satisfy the sample size calculation. Significant differences were found between the groups in knee flexion (F: 113.6+/-8.8 degrees pre-operative, 122.4+/-6.0 degrees intra-operative, 110.2+/-7.5 degrees 1 year, C: 117.4+/-11.7 degrees, 117.4+/-7.6 degrees, 103.5+/-10.7 degrees. p = 0.031) and mental component score of the SF12-v2 (F 53.3+/-13.2, C 61.1+/-73, p = 0.009) but there were no significant differences in other outcomes and patients were equally satisfied. Conclusion: Flexing the femoral implant in this cruciate retaining TKA system provided a significant difference in knee flexion compared to a neutral position. The improvement appears to occur predominantly at surgery and was not associated with a clinical or functional benefit at 1 year. (ACTRN12606000325505). Level of evidence: Level 1; randomised controlled trial. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:257 / 263
页数:7
相关论文
共 50 条
  • [31] Effect of flexion/extension splintage post total knee arthroplasty on blood loss and range of motion - A randomised controlled trial
    Ma, T.
    Khan, R. J. K.
    Smith, R. Carey
    Nivbrant, B.
    Wood, D. J.
    [J]. KNEE, 2008, 15 (01): : 15 - 19
  • [32] Femoral Component Fracture in a Total Knee Arthroplasty Patient With a Persistent Flexion Contracture
    Tate, Jackson P.
    Schneider, Andrew M.
    Brown, Nicholas M.
    [J]. ARTHROPLASTY TODAY, 2023, 22
  • [33] The Effect of Distal Femoral Resection on Fixed Flexion Deformity in Total Knee Arthroplasty
    Liu, David W.
    Reidy, James F.
    Beller, Elaine M.
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (01): : 98 - 102
  • [34] Preoperative flexion does not influence postoperative flexion after rotating-platform total knee arthroplasty
    Russell, Robert D.
    Huo, Michael H.
    de Jong, Leslie
    Jones, Richard E.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (07) : 1644 - 1648
  • [35] Femur bowing could be a risk factor for implant flexion in conventional total knee arthroplasty and notching in navigated total knee arthroplasty
    Ko, Jae Han
    Han, Chang Dong
    Shin, Kyoo Ho
    Nguku, Levis
    Yang, Ick Hwan
    Lee, Woo Suk
    Kim, Kwang Il
    Park, Kwan Kyu
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (08) : 2476 - 2482
  • [36] Preoperative flexion does not influence postoperative flexion after rotating-platform total knee arthroplasty
    Robert D. Russell
    Michael H. Huo
    Leslie de Jong
    Richard E. Jones
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 1644 - 1648
  • [37] Femur bowing could be a risk factor for implant flexion in conventional total knee arthroplasty and notching in navigated total knee arthroplasty
    Jae Han Ko
    Chang Dong Han
    Kyoo Ho Shin
    Levis Nguku
    Ick Hwan Yang
    Woo Suk Lee
    Kwang Il Kim
    Kwan Kyu Park
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 2476 - 2482
  • [38] Does mild flexion of the femoral prosthesis in total knee arthroplasty result in better early postoperative outcomes?
    Zhou, Hang
    Wu, Ze-Rui
    Chen, Xiang-Yang
    Zhang, Le-Shu
    Zhang, Jin-Cheng
    Hidig, Sakarie Mustafe
    Feng, Shuo
    Yang, Zhi
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [39] Does mild flexion of the femoral prosthesis in total knee arthroplasty result in better early postoperative outcomes?
    Hang Zhou
    Ze-Rui Wu
    Xiang-Yang Chen
    Le-Shu Zhang
    Jin-Cheng Zhang
    Sakarie Mustafe Hidig
    Shuo Feng
    Zhi Yang
    [J]. BMC Musculoskeletal Disorders, 24
  • [40] Effect of different postoperative flexion regimes on the outcomes of total knee arthroplasty: randomized controlled trial
    Marcello De Fine
    Francesco Traina
    Gianluca Giavaresi
    Eugenio Leo
    Ilaria Sanzarello
    Fabrizio Perna
    Roberto Dattola
    Cesare Faldini
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 2972 - 2977