Does flexion of the femoral implant in total knee arthroplasty increase knee flexion: A randomised controlled trial

被引:25
|
作者
Murphy, Michael [1 ]
Journeaux, Simon [2 ]
Hides, Julie [3 ]
Russell, Trevor [1 ]
机构
[1] Mater Hlth Serv, Mater Med Res Inst, South Brisbane, Qld 4101, Australia
[2] Univ Queensland, Sch Hlth & Rehabil Sci, St Lucia, Qld 4076, Australia
[3] Australian Catholic Univ, Fac Hlth Sci, Banyo, Qld 4014, Australia
来源
KNEE | 2014年 / 21卷 / 01期
关键词
Total knee arthroplasty; Implant flexion; Knee flexion; Randomised controlled trial; POSTERIOR CONDYLAR OFFSET; FUNCTIONAL-ACTIVITIES; RANGE; MOTION; JOINT; REPLACEMENT; KINEMATICS; COMPONENT; OUTCOMES; HIP;
D O I
10.1016/j.knee.2012.10.028
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Prosthetic and operative modifications in total knee arthroplasty (TKA) have been proposed to maximise post-operative knee flexion as it is essential in routine functional activities. Methods: We performed a double blind randomised controlled trial to compare clinical outcomes of primary cruciate-retaining TKA for osteoarthritis with the femoral component implanted in either 4 flexion in the sagittal plane (F) or in a neutral position (C). The primary outcome of knee flexion and secondary outcomes knee extension, quadriceps strength, WOMAC, SF-12v2, timed stand test, stair climb test and satisfaction were assessed at 1 year. Knee flexion and extension were also assessed intra-operatively. Implant flexion was measured from true lateral radiographs. Results: Thirty-nine participants (40 knees) were recruited, 20 knees per group. Three subjects from the control group and two from the flexed group were lost to 1 year follow-up but numbers were sufficient to satisfy the sample size calculation. Significant differences were found between the groups in knee flexion (F: 113.6+/-8.8 degrees pre-operative, 122.4+/-6.0 degrees intra-operative, 110.2+/-7.5 degrees 1 year, C: 117.4+/-11.7 degrees, 117.4+/-7.6 degrees, 103.5+/-10.7 degrees. p = 0.031) and mental component score of the SF12-v2 (F 53.3+/-13.2, C 61.1+/-73, p = 0.009) but there were no significant differences in other outcomes and patients were equally satisfied. Conclusion: Flexing the femoral implant in this cruciate retaining TKA system provided a significant difference in knee flexion compared to a neutral position. The improvement appears to occur predominantly at surgery and was not associated with a clinical or functional benefit at 1 year. (ACTRN12606000325505). Level of evidence: Level 1; randomised controlled trial. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:257 / 263
页数:7
相关论文
共 50 条
  • [21] Measured Flexion Following Total Knee Arthroplasty
    Mai, Kenny T.
    Verioti, Christopher A.
    Hardwick, Mary E.
    Ezzet, Kace A.
    Copp, Steven N.
    Colwell, Clifford W., Jr.
    [J]. ORTHOPEDICS, 2012, 35 (10) : E1472 - E1475
  • [22] Management of flexion contracture in total knee arthroplasty
    Scuderi, Giles R.
    Kochhar, Tony
    [J]. JOURNAL OF ARTHROPLASTY, 2007, 22 (04): : 20 - 24
  • [23] EFFECT OF TOTAL KNEE ARTHROPLASTY ON MAXIMAL FLEXION
    TEW, M
    FORSTER, IW
    WALLACE, WA
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1989, (247) : 168 - 174
  • [24] Fixed flexion deformity and total knee arthroplasty
    Su, E. P.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (11): : 112 - 115
  • [25] High flexion knee arthroplasty: the relationship between rotational angles and flexion angle after total knee arthroplasty
    Deie, Masataka
    Nakasa, Tomoyuki
    Kamei, Goki
    Nakamae, Atsuo
    Ochi, Mitsuo
    [J]. CURRENT REVIEWS IN MUSCULOSKELETAL MEDICINE, 2014, 7 (02) : 103 - 107
  • [26] High-Flexion Total Knee Arthroplasty
    Long, Williarn J.
    Scuderi, Giles R.
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (07): : 6 - 10
  • [27] Flexion Instability After Total Knee Arthroplasty
    Stambough, Jeffrey B.
    Edwards, Paul K.
    Mannen, Erin M.
    Barnes, C. Lowry
    Mears, Simon C.
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2019, 27 (17) : 642 - 651
  • [28] High flexion knee arthroplasty: the relationship between rotational angles and flexion angle after total knee arthroplasty
    Masataka Deie
    Tomoyuki Nakasa
    Goki Kamei
    Atsuo Nakamae
    Mitsuo Ochi
    [J]. Current Reviews in Musculoskeletal Medicine, 2014, 7 (2) : 103 - 107
  • [29] FLEXION SPACE CONFIGURATION IN TOTAL KNEE ARTHROPLASTY
    LASKIN, RS
    [J]. JOURNAL OF ARTHROPLASTY, 1995, 10 (05): : 657 - 660
  • [30] A dynamic knee extension device improves flexion contracture before total knee arthroplasty: a randomized controlled trial
    Stone, Andrea H.
    Turcotte, Justin J.
    Fowler, M. Brook
    MacDonald, James H.
    Brassard, Marc F.
    King, Paul J.
    [J]. CURRENT ORTHOPAEDIC PRACTICE, 2020, 31 (04): : 347 - 351