Accuracy and precision of electrical permittivity mapping at 3T: the impact of three B1+ mapping techniques

被引:28
|
作者
Gavazzi, Soraya [1 ]
van den Berg, Cornelis A. T. [1 ,2 ]
Sbrizzi, Alessandro [2 ]
Kok, H. Petra [3 ]
Stalpers, Lukas J. A. [3 ]
Lagendijk, Jan J. W. [1 ]
Crezee, Hans [3 ]
van Lier, Astrid L. H. M. W. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiotherapy, POB 85500, NL-3508 GA Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Ctr Image Sci, Utrecht, Netherlands
[3] Univ Amsterdam, Amsterdam UMC, Dept Radiat Oncol, Amsterdam, Netherlands
关键词
accuracy and precision; B-1; mapping; Helmholtz-based EPT; permittivity mapping; MICROWAVE DIELECTRIC-PROPERTIES; IN-VIVO; PROPERTIES TOMOGRAPHY; BIOLOGICAL TISSUES; 7; T; CONDUCTIVITY; ROBUST; EPT; RECONSTRUCTION; PROPAGATION;
D O I
10.1002/mrm.27675
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the sequence-specific impact of B-1(+) amplitude mapping on the accuracy and precision of permittivity reconstruction at 3T in the pelvic region. Methods: B-1(+) maps obtained with actual flip angle imaging (AFI), Bloch Siegert (BS), and dual refocusing echo acquisition mode (DREAM) sequences, set to a clinically feasible scan time of 5 minutes, were compared in terms of accuracy and precision with electromagnetic and Bloch simulations and MR measurements. Permittivity maps were reconstructed based on these B-1(+) maps with Helmholtz -based electrical properties tomography. Accuracy and precision in permittivity were assessed. A 2 compartment phantom with properties and size similar to the human pelvis was used for both simulations and measurements. Measurements were also performed on a female volunteer's pelvis. Results: Accuracy was evaluated with noiseless simulations on the phantom. The maximum B-1(+) bias relative to the true B-1(+) distribution was 1% for AF1 and BS and 6% to 15% for DREAM. This caused an average permittivity bias relative to the true permittivity' of 7% to 20% for AFT and BS and 12% to 35% for DREAM. Precision was assessed in MR experiments. The lowest standard deviation in permittivity, found in the phantom for BS, measured 22.4 relative units and corresponded to a standard deviation in B-1(+) of 0.2% of the B-1(+) average value. As regards B-1(+) precision, in vivo and phantom -measurements were comparable. Conclusions: Our simulation framework quantitatively predicts the different impact of B-1(+) mapping techniques on permittivity reconstruction and shows high sensitivity of permittivity reconstructions to sequence-specitic bias and noise perturbation in the B-1(+) map. These findings arc supported by the experimental results.
引用
收藏
页码:3628 / 3642
页数:15
相关论文
共 50 条
  • [21] Reproducibility of native T1 mapping for renal tissue characterization at 3T
    Dekkers, Ilona A.
    Paiman, Elisabeth H. M.
    de Vries, Aiko P. J.
    Lamb, Hildo J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (02) : 588 - 596
  • [22] Ultrafast Volumetric B1+ Mapping for Improved Radiofrequency Shimming in 3 Tesla Body MRI
    Sprinkart, Alois M.
    Nehrke, Kay
    Traeber, Frank
    Block, Wolfgang
    Gieseke, Juergen
    Schmitz, Georg
    Willinek, Winfried A.
    Schild, Hans
    Bornert, Peter
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (04) : 857 - 863
  • [23] T1 mapping and T2 mapping at 3T for quantifying the area-at-risk in reperfused STEMI patients
    Bulluck, Heerajnarain
    White, Steven K.
    Rosmini, Stefania
    Bhuva, Anish
    Treibel, Thomas A.
    Fontana, Marianna
    Abdel-Gadir, Amna
    Herrey, Anna
    Manisty, Charlotte
    Wan, Simon M. Y.
    Groves, Ashley
    Menezes, Leon
    Moon, James C.
    Hausenloy, Derek J.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [24] Simultaneous T1 and B1+ Mapping Using Reference Region Variable Flip Angle Imaging
    Sung, Kyunghyun
    Saranathan, Manojkumar
    Daniel, Bruce L.
    Hargreaves, Brian A.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (04) : 954 - 961
  • [25] T1 mapping and T2 mapping at 3T for quantifying the area-at-risk in reperfused STEMI patients
    Heerajnarain Bulluck
    Steven K. White
    Stefania Rosmini
    Anish Bhuva
    Thomas A. Treibel
    Marianna Fontana
    Amna Abdel-Gadir
    Anna Herrey
    Charlotte Manisty
    Simon M. Y. Wan
    Ashley Groves
    Leon Menezes
    James C. Moon
    Derek J. Hausenloy
    Journal of Cardiovascular Magnetic Resonance, 17
  • [26] CMR T1 Mapping at 3T Characterizes the Extent of Acute Ischemic Myocardial Injury: Comparison to Standard Techniques
    Dall'Armellina, Erica
    Piechnik, Stefan
    Ferreira, Vanessa
    Karamitsos, Theodoros D.
    Francis, Jane M.
    Cuculi, Florim
    Forfar, Colin
    Prendergast, Bernard D.
    Banning, Adrian P.
    Channon, Keith M.
    Kharbanda, Rajesh K.
    Robson, Matthew D.
    Choudhury, Robin P.
    Neubauer, Stefan
    CIRCULATION, 2011, 124 (21)
  • [27] Free-breathing 3D cardiac T-1 mapping with transmit B-1 correction at 3T
    Han, Paul Kyu
    Marin, Thibault
    Djebra, Yanis
    Landes, Vanessa
    Zhuo, Yue
    El Fakhri, Georges
    Ma, Chao
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (04) : 1832 - 1845
  • [28] Simple modification of arm position improves B1+ and signal homogeneity in the thoracolumbar spine at 3T
    Ishizaka, Kinya
    Kudo, Kohsuke
    Harada, Kuniaki
    Shirai, Toru
    Fujiwara, Taro
    Aoike, Suzuko
    Takamori, Sayaka
    Shirato, Hiroki
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (01) : 123 - 130
  • [29] Self-navigated three-dimensional cardiac T2 mapping at 3T
    Ruud B van Heeswijk
    Davide Piccini
    Hélène Feliciano
    Juerg Schwitter
    Matthias Stuber
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [30] Fast 3D 31P B1+ mapping with a weighted stack of spiral trajectory at 7 T
    Widmaier, Mark Stephan
    Kaiser, Antonia
    Baup, Salome
    Wenz, Daniel
    Pierzchala, Katarzyna
    Xiao, Ying
    Huang, Zhiwei
    Jiang, Yun
    Xin, Lijing
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (02) : 481 - 489