Pre-analytical variables in haemostasis: Findings from the United Kingdom National External Quality Assessment scheme for Blood Coagulation (UK NEQAS BC) haemolysis exercise

被引:2
|
作者
Brown, Lilia [1 ]
Jennings, Ian [1 ]
Kitchen, Steve [1 ]
Kitchen, Dianne P. [1 ]
Woods, Tim A. L. [1 ]
Walker, Isobel D. [1 ]
机构
[1] UK NEQAS Blood Coagulat, 3rd Floor Pegasus House,463A Glossop Rd, Sheffield S10 2QD, S Yorkshire, England
关键词
haemolysis; haemostasis; pre‐ analytical variables; quality; CLINICAL-CHEMISTRY; SPURIOUS HEMOLYSIS; INTERFERENCE; ICTERUS;
D O I
10.1111/ijlh.13468
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Haemolysis is considered one of the major contributors of nonconformities and sample rejection in coagulation testing. Materials and methods Two lyophilized plasmas were distributed to 800 centres registered for prothrombin time (PT), activated partial thromboplastin time (APTT) and either Clauss fibrinogen or thrombin time (TT) in the UK NEQAS BC programme. The same pool of normal plasma was used to prepare both samples, to one of which red blood cell haemolysate was added to mimic haemolysis at 3 g/L haemoglobin concentration. Participants were asked to complete a questionnaire about their laboratory approach to dealing with haemolysed samples, including strategies used to deal with different levels of haemolysis. Results Results for tests performed did not show great differences between the two samples. It should be noted that artificially constructed haemolysed samples may not behave in the same way as patient samples (ie, may not be commutable). However, the possibility of carrying out a large multicentre study for detection of haemolysis was demonstrated. Inconsistency in practice was observed with 226/551 (41%) of centres indicated they reject haemolysed samples solely on visual checks, and 163 (30%) using initial visual checks with further sample rejection evaluation by analyser flags. Furthermore, 333 (72%) of centres indicated that the level of haemolysis affects sample rejection decisions, while 132 (28%) stated it did not. Conclusion Variability of responses for dealing with haemolysed samples reflects a lack of clear consistency in the pre-analytical area of sample processing.
引用
收藏
页码:1198 / 1206
页数:9
相关论文
共 40 条
  • [21] Near patient testing in blood coagulation: 18 months of UK National External Quality Assessment Scheme surveys
    Woods, TAL
    Jennings, I
    Kitchen, S
    Preston, FE
    BRITISH JOURNAL OF HAEMATOLOGY, 1998, 102 (01) : 260 - 260
  • [22] Comparability of antimicrobial susceptibility test results from 22 European countries and Israel: an external quality assurance exercise of the European Antimicrobial Resistance Surveillance System (EARSS) in collaboration with the United Kingdom National External Quality Assurance Scheme (UK NEQAS)
    Bronzwaer, S
    Buchholz, U
    Courvalin, P
    Snell, J
    Cornaglia, G
    de Neeling, A
    Aubry-Damon, H
    Degener, J
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2002, 50 (06) : 953 - 964
  • [23] Platelet function testing: practice among UK National External Quality Assessment Scheme for Blood Coagulation participants, 2006
    Jennings, I.
    Woods, T. A. L.
    Kitchen, S.
    Walker, I. D.
    JOURNAL OF CLINICAL PATHOLOGY, 2008, 61 (08) : 950 - 954
  • [24] INR MEASUREMENT DATA FROM THE UK NATIONAL EXTERNAL QUALITY ASSESSMENT FOR BLOOD COAGULATION PROGRAMME 2023
    Reilly-Stitt, Christopher M. P.
    Jennings, Ian
    Uppal, Varun
    Horner, Kevin
    Kitchen, Steve
    Walker, Isobel
    Williams, Anna
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2024, 46 : 86 - 86
  • [25] ERRORS IN BACTERIOLOGICAL TECHNIQUES - RESULTS FROM THE UNITED-KINGDOM NATIONAL EXTERNAL QUALITY ASSESSMENT SCHEME FOR MICROBIOLOGY
    SNELL, JJS
    DEMELLO, JV
    PHUA, TJ
    MEDICAL LABORATORY SCIENCES, 1986, 43 (04): : 344 - 355
  • [26] DIAGNOSING HEPARIN INDUCED THROMBOCYTOPENIA: CURRENT PRACTICE AMONGST PARTICIPANTS OF THE UK NATIONAL EXTERNAL QUALITY ASSESSMENT SCHEME FOR BLOOD COAGULATION
    Walker, S.
    Kitchen, S.
    Jennings, I.
    Homer, K.
    Kitchen, D.
    Woods, T. A. L.
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2008, 93 : 344 - 344
  • [27] Laboratory tests for measurement of von Willebrand factor show poor agreement among different centers: Results from the United Kingdom National External Quality Assessment Scheme for Blood Coagulation
    Kitchen, Steve
    Jennings, Ion
    Woods, Tim A. L.
    Kitchen, Dianne P.
    Walker, Isobel D.
    Preston, Francis E.
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2006, 32 (05): : 492 - 498
  • [28] Laboratory assays for patients receiving Argatroban therapy or normal plasma spiked with Argatroban: A review of UK NEQAS (Blood Coagulation) External Quality Assessment Scheme exercises 2021
    Reilly-Stitt, Christopher
    Jennings, Ian
    Kitchen, Steve
    Guy, Susan
    Walker, Isobel
    BRITISH JOURNAL OF HAEMATOLOGY, 2022, 197 : 150 - 150
  • [29] The United Kingdom National External Quality Assessment Scheme (blood transfusion laboratory practice): trends in proficiency and practice between 1985 and 2000
    Knowles, SM
    Milkins, CE
    Chapman, JF
    Scott, M
    TRANSFUSION MEDICINE, 2002, 12 (01) : 11 - 23
  • [30] Laboratory Performance of Serum B12 Assay in the United Kingdom (UK) As Assessed By the UK National External Quality Assessment Scheme for Haematinics: Implications for Clinical Interpretation
    Mackenzie, Finlay
    Devalia, Vinod
    BLOOD, 2018, 132