Detection of colorectal polyps: Comparison of multi-detector row CT and MR colonography in a colon phantom

被引:14
|
作者
Wessling, Johannes
Fischbach, Roman
Borchert, Alexandra
Kugel, Harald
Allkemper, Thomas
Osada, Nani
Heindel, Walter
机构
[1] Univ Munster, Dept Clin Radiol, D-48149 Munster, Germany
[2] Univ Munster, Dept Med Informat & Biomath, D-48149 Munster, Germany
关键词
D O I
10.1148/radiol.2411050292
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare multi-detector row (four- and 16-section) computed tomography (CT), including a low-dose protocol, with high-field-strength (1.5- and 3.0-T) magnetic resonance (MR) imaging for reader detection of colorectal polyps in a colon phantom. Materials and Methods: A colon phantom with simulated haustral folds and 10 polyps of varying size (2.0 - 8.0 mm) was imaged at four-and 16-section CT (section thicknesses of 1.25 and 0.75 mm, reconstruction increments of 0.8 and 0.7 mm, and 100 and 10 mAs, respectively, and 120 kV for both) and at 1.5- and 3.0-T MR imaging (three-dimensional gradient-recalled echo sequence, section thickness of 1.4 mm). Three-dimensional endoluminal images were assessed by 10 reviewers for each modality regarding polyp detection. Comparisons of sensitivities were performed by using logistic regression. Results: Overall, polyps were detected with a sensitivity of 87% (95% confidence interval [CI]: 80%, 94%) at four- section CT, 92% (95% CI: 87%, 97%) at 16-section CT, 56% (95% CI: 46%, 66%) at 1.5- T MR imaging, and 55% (95% CI: 45%, 65%) at 3.0-T MR imaging. The detection of polyps at least 4 mm in diameter was not influenced by the modality or radiation dose (sensitivity of 100%). CT performed in low-dose mode depicted all polyps with a diameter of at least 3 mm. Polyps smaller than 3 mm in diameter were detected with a sensitivity of 7.5% ( 1.5- T MR imaging), 22.5% (3.0-T MR imaging), and 20% (low-dose CT); detection rates were significantly greater (P < .001) with normal-dose CT (four section, 67.5%; 16 section, 82.5%). Increased spatial resolution (with CT) and higher field strength (with MR imaging) had no significant effect on polyp detection. Conclusion: With both multi - detector row CT and MR imaging, readers detected polyps above the clinically relevant threshold diameter of 6 mm, with similar sensitivities.
引用
收藏
页码:125 / 131
页数:7
相关论文
共 50 条
  • [1] Prospective comparison of 64 multi-detector row CT colonography and conventional colonoscopy for the detection of colorectal polyps
    Chang, Uk Sun
    Park, Dong Kyun
    Kim, Ju Hyun
    Kim, Yu Kyung
    Kwon, Kwang An
    Yu, Sang Kyun
    Song, Kee Sup
    Jung, Hyuk Sang
    Jang, Chang Soo
    Kim, Min Ju
    Park, Chul Hee
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2006, 21 : A503 - A503
  • [2] CT colonography: Protocol optimization with multi-detector row CT - Study in an anthropomorphic colon phantom
    Wessling, J
    Fischbach, R
    Meier, N
    Allkemper, T
    Klusmeier, J
    Ludwig, K
    Heindel, W
    RADIOLOGY, 2003, 228 (03) : 753 - 759
  • [3] Colorectal polyps: Detection with low-dose multi-detector row helical CT colonography versus two sequential colonoscopies
    Iannaccone, R
    Catalano, C
    Mangiapane, F
    Murakami, T
    Lamazza, A
    Fiori, E
    Schillaci, A
    Marin, D
    Nofroni, I
    Hori, M
    Passariello, R
    RADIOLOGY, 2005, 237 (03) : 927 - 937
  • [4] Science to practice - What multi-detector row CT parameters are best for detection of colon polyps?
    Brink, JA
    RADIOLOGY, 2003, 229 (01) : 1 - 2
  • [5] Colonic distention in multi-detector row CT colonography
    Bruzzi, JF
    Fenlon, HM
    RADIOLOGY, 2004, 231 (01) : 282 - 282
  • [6] Cardiovascular effects at multi-detector row CT colonography compared with those at conventional endoscopy of the colon
    Taylor, SA
    Halligan, S
    O'Donnell, C
    Morley, S
    Mistry, H
    Saunders, BP
    Vance, M
    Bassett, P
    Windsor, A
    Stern, Y
    Bethel, H
    Atkin, W
    Bartram, CI
    RADIOLOGY, 2003, 229 (03) : 782 - 790
  • [7] Computer-aided detection of polyps in CT colonography: Performance comparison between single- and multi-detector CT
    Yoshida, H
    Nappi, JJ
    Frimmel, H
    Miller, FH
    Dalal, KA
    Dachman, AH
    RADIOLOGY, 2002, 225 : 304 - 305
  • [8] CT colonography: Single-versus multi-detector row imaging
    Hara, AK
    Johnson, CD
    MacCarty, RL
    Welch, TJ
    McCollough, CH
    Harmen, WS
    RADIOLOGY, 2001, 219 (02) : 461 - 465
  • [9] Colorectal neoplasms: Prospective comparison of thin-section low-dose multi-detector row CT colonography and conventional colonoscopy for detection
    Macari, M
    Bini, EJ
    Xue, XN
    Milano, A
    Katz, SS
    Resnick, D
    Chandarana, H
    Krinsky, G
    Klingenbeck, K
    Marshall, CH
    Megibow, AJ
    RADIOLOGY, 2002, 224 (02) : 383 - 392
  • [10] Detection of low-contrast objects: Experimental comparison of single- and multi-detector row CT with a phantom
    Verdun, FR
    Denys, A
    Valley, JF
    Schnyder, P
    Meuli, RA
    RADIOLOGY, 2002, 223 (02) : 426 - 431