Diagnosis of fast ions produced by negative-ion neutral-beam injection with fast-ion deuterium-alpha spectroscopy

被引:6
|
作者
Muscatello, C. M. [1 ]
Heidbrink, W. W. [2 ]
Boivin, R. L. [1 ]
Chrystal, C. [1 ]
Collins, C. S. [1 ]
Fujiwara, Y. [3 ]
Yamaguchi, H. [3 ]
机构
[1] Gen Atom, POB 85608, San Diego, CA 92186 USA
[2] Univ Calif Irvine, Dept Phys & Astron, Irvine, CA 92697 USA
[3] Natl Inst Fus Sci, 322-6 Oroshi, Toki, Gifu 5095292, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2019年 / 90卷 / 07期
关键词
ALFVEN EIGENMODES; TRANSPORT; PROFILES; EMISSION; PLASMAS; CODE;
D O I
10.1063/1.5099491
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Negative-ion neutral-beam injection (NNBI) is an important source of heating and current drive for next-step fusion devices where the injected energy can range from hundreds of keV to 1 MeV. Few diagnostics are suitable for phase-space resolved measurements of fast ions with energy in excess of 100 keV. A study to assess the feasibility of fast-ion deuterium-alpha (FIDA) spectroscopy to diagnose high-energy ions produced by NNBI is presented. Case studies with the Large Helical Device (LHD) and JT-60SA illustrate possible solutions for the measurement. The distribution function of fast ions produced by NNBI is calculated for both devices, and the FIDA spectrum is predicted by synthetic diagnostic simulation. Results with 180 keV NNBI in LHD show that, with a judicious choice of viewing geometry, the FIDA intensity is comparable to that obtained with the existing FIDA system. The measurement is more challenging with the 500 keV NNBI in JT-60SA. Simulations predict the FIDA intensity to be about 1% of the background bremsstrahlung, which is small compared to existing FIDA implementations with positive neutral-beam injection where signal levels are an order of magnitude larger. The sampling time required to extract the small FIDA signal is determined using a probabilistic approach. Results indicate that long averaging periods, from ones to tens of seconds, are needed to resolve the FIDA signal in JT-60SA. These long averaging times are suitable in long-pulse (similar to 100 s), steady-state devices like JT-60SA where an important measurement objective is the spatial profile of the slowing-down distribution of fast ions.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] ENHANCEMENT OF MOLECULAR ION INTENSITY OF NUCLEIC-ACIDS IN NEGATIVE-ION FAST-ATOM-BOMBARDMENT MASS-SPECTROSCOPY
    SANDSTROM, A
    CHATTOPADHYAYA, J
    JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1987, (11) : 862 - 864
  • [43] HIGH-ENERGY NEGATIVE-ION BASED NEUTRAL BEAM INJECTION SYSTEM FOR JT-60U
    KURIYAMA, M
    AKINO, N
    ARAKI, M
    EBISAWA, N
    HANADA, M
    INOUE, T
    KAWAI, M
    KAZAWA, M
    KOIZUMI, J
    KUNIEDA, T
    MATSUOKA, M
    MIYAMOTO, K
    MIZUNO, M
    MOGAKI, K
    OHARA, Y
    OHGA, T
    OKUMURA, Y
    OOHARA, H
    SATOH, F
    SUZUKI, T
    TAKAHASHI, S
    TAKAYASU, T
    USAMI, H
    USUI, K
    WATANABE, K
    YAMAMOTO, M
    YAMAZAKI, T
    FUSION ENGINEERING AND DESIGN, 1995, 26 (1-4) : 445 - 453
  • [44] A STUDY OF THE POSITIVE AND NEGATIVE-ION FAST ATOM BOMBARDMENT MASS-SPECTRA OF ALPHA-AMINO-ACIDS
    KULIK, W
    HEERMA, W
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 15 (08): : 419 - 427
  • [45] Analytical and Statistical Modelling of a Fast Ion Source Formed by Injection of a Neutral Beam into Magnetically Confined Plasma
    Goncharov, Pavel
    ATOMS, 2023, 11 (02)
  • [46] Interaction of neutral beam (NB) injected fast ions with ion cyclotron resonance frequency (ICRF) waves
    Choi, M
    Chan, VS
    Chiu, SC
    Omelchenko, YA
    Sentoku, Y
    John, HES
    RADIO FREQUENCY POWER IN PLASMAS, 2003, 694 : 86 - 89
  • [47] Beam deflection by plasma grid filter current in the negative-ion source for JT-60U neutral beam injection system
    Umeda, N
    Ikeda, Y
    Hanada, M
    Inoue, T
    Kawai, M
    Kazawa, M
    Komata, M
    Mogaki, K
    Ohga, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (03):
  • [48] Fast-ion velocity-space tomography using slowing-down regularization in EAST plasmas with co- and counter-current neutral beam injection
    Madsen, B.
    Huang, J.
    Salewski, M.
    Jarleblad, H.
    Hansen, P. C.
    Stagner, L.
    Su, J.
    Chang, J. F.
    Fu, J.
    Wang, J. F.
    Liang, L. Z.
    Zhong, G. Q.
    Li, Y. Y.
    Lyu, B.
    Liu, H. Q.
    Zang, Q.
    Luo, Z. P.
    Nocente, M.
    Moseev, D.
    Fan, T. S.
    Zhang, Y. M.
    Yang, D.
    Sun, J. Q.
    Liao, L. Y.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2020, 62 (11)
  • [50] FAST-ATOM-BOMBARDMENT, NEGATIVE-ION MASS-SPECTROMETRY OF THE MYCOBACTERIAL O-METHYL-DEUTERIUM-GLUCOSE POLYSACCHARIDE AND LIPOPOLYSACCHARIDES
    DELL, A
    BALLOU, CE
    CARBOHYDRATE RESEARCH, 1983, 120 (AUG) : 95 - 111