Diagnosis of fast ions produced by negative-ion neutral-beam injection with fast-ion deuterium-alpha spectroscopy

被引:6
|
作者
Muscatello, C. M. [1 ]
Heidbrink, W. W. [2 ]
Boivin, R. L. [1 ]
Chrystal, C. [1 ]
Collins, C. S. [1 ]
Fujiwara, Y. [3 ]
Yamaguchi, H. [3 ]
机构
[1] Gen Atom, POB 85608, San Diego, CA 92186 USA
[2] Univ Calif Irvine, Dept Phys & Astron, Irvine, CA 92697 USA
[3] Natl Inst Fus Sci, 322-6 Oroshi, Toki, Gifu 5095292, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2019年 / 90卷 / 07期
关键词
ALFVEN EIGENMODES; TRANSPORT; PROFILES; EMISSION; PLASMAS; CODE;
D O I
10.1063/1.5099491
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Negative-ion neutral-beam injection (NNBI) is an important source of heating and current drive for next-step fusion devices where the injected energy can range from hundreds of keV to 1 MeV. Few diagnostics are suitable for phase-space resolved measurements of fast ions with energy in excess of 100 keV. A study to assess the feasibility of fast-ion deuterium-alpha (FIDA) spectroscopy to diagnose high-energy ions produced by NNBI is presented. Case studies with the Large Helical Device (LHD) and JT-60SA illustrate possible solutions for the measurement. The distribution function of fast ions produced by NNBI is calculated for both devices, and the FIDA spectrum is predicted by synthetic diagnostic simulation. Results with 180 keV NNBI in LHD show that, with a judicious choice of viewing geometry, the FIDA intensity is comparable to that obtained with the existing FIDA system. The measurement is more challenging with the 500 keV NNBI in JT-60SA. Simulations predict the FIDA intensity to be about 1% of the background bremsstrahlung, which is small compared to existing FIDA implementations with positive neutral-beam injection where signal levels are an order of magnitude larger. The sampling time required to extract the small FIDA signal is determined using a probabilistic approach. Results indicate that long averaging periods, from ones to tens of seconds, are needed to resolve the FIDA signal in JT-60SA. These long averaging times are suitable in long-pulse (similar to 100 s), steady-state devices like JT-60SA where an important measurement objective is the spatial profile of the slowing-down distribution of fast ions.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Multi-view fast-ion D-alpha spectroscopy diagnostic at ASDEX Upgrade
    Geiger, B.
    Dux, R.
    McDermott, R. M.
    Potzel, S.
    Reich, M.
    Ryter, F.
    Weiland, M.
    Wuenderlich, D.
    Garcia-Munoz, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (11):
  • [32] CONFINEMENT OF HELICALLY TRAPPED FAST-ION ORBITS IN A NEUTRAL-BEAM-SUSTAINED HELIOTRON E PLASMA
    HANATANI, K
    NAKASHIMA, Y
    ZUSHI, H
    SANO, F
    MOTOJIMA, O
    WAKATANI, M
    OBIKI, T
    IIYOSHI, A
    UO, K
    NUCLEAR FUSION, 1985, 25 (03) : 259 - 273
  • [33] MAJORITY ION HEATING BY NEUTRAL BEAM INJECTION AND CONFINEMENT OF FAST IONS IN THE MADISON SYMMETRIC TORUS REVERSED FIELD PINCH
    Anderson, J. K.
    Almagri, A. F.
    Chapman, B. E.
    Davydenko, V. I.
    Deichuli, P.
    Den Hartog, D. J.
    Forest, C. B.
    Fiksel, G.
    Ivanov, A. A.
    Liu, D.
    Nornberg, M. D.
    Sarff, J. S.
    Stupishin, N.
    Waksman, J.
    FUSION SCIENCE AND TECHNOLOGY, 2011, 59 (1T) : 27 - 30
  • [34] Tomography of fast ion distribution function under neutral beam injection and ion cyclotron resonance heating on EAST
    Sun, Yan-Xu
    Huang, Juan
    Gao, Wei
    Chang, Jia-Feng
    Zhang, Wei
    Shi, Chang
    Li, Yun-He
    ACTA PHYSICA SINICA, 2023, 72 (21)
  • [35] High energy negative-ion based neutral beam injection system for JT-60U
    Japan Atomic Energy Research Inst, Ibaraki-ken, Japan
    Fusion Eng Des, 1-4 (445-453):
  • [37] NEGATIVE-ION FAST ATOM BOMBARDMENT MASS-SPECTROMETRY FOR NATIVE GANGLIOSIDES USING A NEUTRAL MATRIX
    ISOBE, R
    KAWANO, Y
    HIGUCHI, R
    KOMORI, T
    ANALYTICAL BIOCHEMISTRY, 1989, 177 (02) : 296 - 299
  • [38] Ion cyclotron emission driven by deuterium neutral beam injection and core fusion reaction ions in EAST
    Liu, Lunan
    Zhang, Xinjun
    Zhu, Yubao
    Qin, Chengming
    Zhao, Yanping
    Yuan, Shuai
    Mao, Yuzhou
    Li, Miaohui
    Zhang, Kai
    Cheng, Jian
    Ai, Lin
    Cheng, Yan
    NUCLEAR FUSION, 2020, 60 (04)
  • [39] Progress in modelling fast-ion D-alpha spectra and neutral particle analyzer fluxes using FIDASIM
    Geiger, B.
    Stagner, L.
    Heidbrink, W. W.
    Dux, R.
    Fischer, R.
    Fujiwara, Y.
    Garcia, A. V.
    Jacobsen, A. S.
    Jansen van Vuuren, A.
    Karpushov, A. N.
    Liu, D.
    Schneider, P. A.
    Sfiligoi, I.
    Zs. Poloskei, P.
    Weiland, M.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2020, 62 (10)
  • [40] Continuous-wave cavity ringdown spectroscopy of molecular ions in a fast ion beam
    Weaver, Susanna L. Widicus
    Mills, Andrew A.
    McCall, Benjamin J.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 233