Diagnosis of fast ions produced by negative-ion neutral-beam injection with fast-ion deuterium-alpha spectroscopy

被引:6
|
作者
Muscatello, C. M. [1 ]
Heidbrink, W. W. [2 ]
Boivin, R. L. [1 ]
Chrystal, C. [1 ]
Collins, C. S. [1 ]
Fujiwara, Y. [3 ]
Yamaguchi, H. [3 ]
机构
[1] Gen Atom, POB 85608, San Diego, CA 92186 USA
[2] Univ Calif Irvine, Dept Phys & Astron, Irvine, CA 92697 USA
[3] Natl Inst Fus Sci, 322-6 Oroshi, Toki, Gifu 5095292, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2019年 / 90卷 / 07期
关键词
ALFVEN EIGENMODES; TRANSPORT; PROFILES; EMISSION; PLASMAS; CODE;
D O I
10.1063/1.5099491
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Negative-ion neutral-beam injection (NNBI) is an important source of heating and current drive for next-step fusion devices where the injected energy can range from hundreds of keV to 1 MeV. Few diagnostics are suitable for phase-space resolved measurements of fast ions with energy in excess of 100 keV. A study to assess the feasibility of fast-ion deuterium-alpha (FIDA) spectroscopy to diagnose high-energy ions produced by NNBI is presented. Case studies with the Large Helical Device (LHD) and JT-60SA illustrate possible solutions for the measurement. The distribution function of fast ions produced by NNBI is calculated for both devices, and the FIDA spectrum is predicted by synthetic diagnostic simulation. Results with 180 keV NNBI in LHD show that, with a judicious choice of viewing geometry, the FIDA intensity is comparable to that obtained with the existing FIDA system. The measurement is more challenging with the 500 keV NNBI in JT-60SA. Simulations predict the FIDA intensity to be about 1% of the background bremsstrahlung, which is small compared to existing FIDA implementations with positive neutral-beam injection where signal levels are an order of magnitude larger. The sampling time required to extract the small FIDA signal is determined using a probabilistic approach. Results indicate that long averaging periods, from ones to tens of seconds, are needed to resolve the FIDA signal in JT-60SA. These long averaging times are suitable in long-pulse (similar to 100 s), steady-state devices like JT-60SA where an important measurement objective is the spatial profile of the slowing-down distribution of fast ions.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] NEUTRAL-BEAM INJECTION INTO A TOKAMA .1. FAST-ION SPATIAL-DISTRIBUTION FOR TANGENTIAL INJECTION
    ROME, JA
    CALLEN, JD
    CLARKE, JF
    NUCLEAR FUSION, 1974, 14 (02) : 141 - 151
  • [2] DESIGN OF A NEGATIVE-ION NEUTRAL-BEAM SYSTEM FOR TNS
    EASOZ, JR
    SINK, DA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1979, 32 (JUN): : 80 - 81
  • [3] Anomalous Fast-Ion Transport During Neutral Beam Injection on EAST
    Zhao, Y. A.
    Zhang, X. M.
    Yu, L. M.
    Xue, E. B.
    Chen, W. D.
    PLASMA PHYSICS REPORTS, 2018, 44 (10) : 891 - 898
  • [4] Anomalous Fast-Ion Transport During Neutral Beam Injection on EAST
    Y. A. Zhao
    X. M. Zhang
    L. M. Yu
    E. B. Xue
    W. D. Chen
    Plasma Physics Reports, 2018, 44 : 891 - 898
  • [5] Validation of fast-ion D-alpha spectrum measurements during EAST neutral-beam heated plasmas
    Huang, J.
    Heidbrink, W. W.
    von Hellermann, M. G.
    Stagner, L.
    Wu, C. R.
    Hou, Y. M.
    Chang, J. F.
    Ding, S. Y.
    Chen, Y. J.
    Zhu, Y. B.
    Jin, Z.
    Xu, Z.
    Gao, W.
    Wang, J. F.
    Lyu, B.
    Zang, Q.
    Zhong, G. Q.
    Hu, L.
    Wan, B.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [6] Charge-exchange measurements of high-energy fast ions in LHD using negative-ion neutral beam injection
    Hayashi, W. H. J.
    Heidbrink, W. W.
    Muscatello, C. M.
    Lin, D. J.
    Osakabe, M.
    Ogawa, K.
    Kawamoto, Y.
    Yamaguchi, H.
    Seki, R.
    Nuga, H.
    Isobe, M.
    Fujiwara, Y.
    Kamio, S.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (12):
  • [7] Velocity-space studies of fast-ion transport at a sawtooth crash in neutral-beam heated plasmas
    Muscatello, C. M.
    Heidbrink, W. W.
    Kolesnichenko, Ya I.
    Lutsenko, V. V.
    Van Zeeland, M. A.
    Yakovenko, Yu V.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2012, 54 (02)
  • [8] Studying fast-ion populations using oscillations in solid-state neutral-particle analyzer signal and neutral-beam injection power
    Parr, E.
    Mcclements, K. G.
    Heidbrink, W. W.
    Michael, C. A.
    Prechel, G.
    Rivero-Rodriguez, J. F.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (01):
  • [9] Development of a narrow stopband filter for spectroscopic fast ion deuterium-alpha measurements
    Lin, D. J.
    Muscatello, C. M.
    Heidbrink, W. W.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (03):
  • [10] CHARACTERIZATION OF FAST-ION BEHAVIOR DURING TANGENTIAL NEUTRAL BEAM INJECTION IN THE ADVANCED TOROIDAL FACILITY
    WADE, MR
    THOMAS, CE
    COLCHIN, RJ
    ROME, JA
    ENGLAND, AC
    FOWLER, RH
    NUCLEAR FUSION, 1995, 35 (09) : 1029 - 1045