Parametric study on dispersed phase holdup and axial drop size distribution in a pulsed disc and doughnut extraction column

被引:13
|
作者
Sinha, Vivekananda [1 ]
Vincent, Tessy [2 ]
机构
[1] Bhabha Atom Res Ctr, Homi Bhabha Natl Inst, Mumbai 400085, Maharashtra, India
[2] Bhabha Atom Res Ctr, Proc Dev Div, Mumbai, Maharashtra, India
关键词
Dispersed phase holdup; axial drop size distribution; specific power consumption; cumulative volume distribution; unified correlation;
D O I
10.1080/01496395.2020.1847146
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A parametric study of the dispersed phase holdup, specific power consumption (P) and axial drop size distribution (ADSD) in a pulsed disc and doughnut column have been carried out with 30% Tri-Butyl Phosphate- 0.01 M nitric acid system. 'P' and holdup decreases with increasing percentage duty cycle and increases exponentially with increased pulsation. Whereas 'P' remains almost independent of total superficial velocity and phase flow ratio. At the top of the extraction section, the most uniform DSD have been observed. Subsequently, Unified empirical correlations have been developed over much wider range for predicting the holdup and Sauter mean diameter.
引用
收藏
页码:2801 / 2825
页数:25
相关论文
共 50 条
  • [21] Spray extraction columns: Drop size and dispersed-phase holdup
    Varfolomeev B.G.
    Pebalk V.L.
    Chigogidze K.Sh.
    Lan N.N.
    Fernando R.S.
    Theoretical Foundations of Chemical Engineering, 2000, 34 (6) : 556 - 561
  • [22] Spray extraction columns: Drop size and dispersed-phase holdup
    Varfolomeev, BG
    Pebalk, VL
    Chigogidze, KS
    Lan, NN
    Fernando, RS
    THEORETICAL FOUNDATIONS OF CHEMICAL ENGINEERING, 2000, 34 (06) : 556 - 561
  • [23] Axial dispersion, holdup and slip velocity of dispersed phase in a pulsed sieve plate extraction column by radiotracer residence time distribution analysis
    Din, Ghiyas Ud
    Chughtai, Imran Rafiq
    Inayat, Mansoor Hameed
    Khan, Iqbal Hussain
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (12) : 1818 - 1824
  • [24] Study of axial mixing, holdup and slip velocity of dispersed phase in a pulsed sieve plate extraction column using radiotracer technique
    Din, Ghiyas Ud
    Chughtai, Imran Rafiq
    Inayat, Mansoor Hameed
    Khan, Iqbal Hussain
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : 1248 - 1253
  • [25] Drop size distribution and mean drop size in a pulsed packed extraction column
    Samani, M. Gholam
    Asl, A. Haghighi
    Safdari, J.
    Torab-Mostaedi, M.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2012, 90 (12): : 2148 - 2154
  • [26] Performance of an Industrial Pulsed Disc-and-Doughnut Extraction Column
    Wang, Yong
    Mumford, Kathryn A.
    Smith, Kathryn H.
    Ballestrin, Simon
    Li, Zheng
    Stevens, Geoffrey W.
    SOLVENT EXTRACTION AND ION EXCHANGE, 2016, 34 (02) : 161 - 171
  • [27] Mass transfer studies for a pulsed disc and doughnut extraction column
    Jahya, AB
    Stevens, GW
    Pratt, HRC
    MINPREX 2000: INTERNATIONAL CONGRESS ON MINERAL PROCESSING AND EXTRACTIVE METALLURGY, 2000, 2000 (05): : 281 - 284
  • [28] DROP SIZE AND HOLDUP IN A RECIPROCATING PLATE EXTRACTION COLUMN
    BAIRD, MHI
    LANE, SJ
    CHEMICAL ENGINEERING SCIENCE, 1973, 28 (03) : 947 - 957
  • [29] Study of mass transfer and determination of drop size distribution in a pulsed extraction column
    Ousmane, Syll
    Isabelle, Mabille
    Mario, Moscosa-Santillan
    Mamadou, Traore
    Jacques, Amouroux
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2011, 89 (1A): : 60 - 68
  • [30] DISPERSED PHASE HOLDUP AND DROP SIZE DISTRIBUTION IN A ROTATING PERFORATED DISK CONTACTOR
    冯毓如
    裘元焘
    时钧
    Journal of Chemical Industry and Engineering, 1991, (01) : 28 - 37