Study of mass transfer and determination of drop size distribution in a pulsed extraction column

被引:27
|
作者
Ousmane, Syll [1 ]
Isabelle, Mabille [1 ]
Mario, Moscosa-Santillan [2 ]
Mamadou, Traore [1 ]
Jacques, Amouroux [1 ]
机构
[1] Ecole Natl Super Chim Paris, UPMC ENSCP, EA3492, Lab Genie Procedes Plasmas & Traitements Surface, F-75231 Paris 05, France
[2] Zona Univ, Ctr Invest & Estudios Posgrad, Fac Ciencias Quim, UASLP, San Luis Potosi, Slp, Mexico
来源
关键词
Pulsed extraction column; Drop size distribution; Sauter diameter (d32); Discontinuous phase hold up; LIQUID-LIQUID DISPERSIONS; SYSTEM;
D O I
10.1016/j.cherd.2010.04.011
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A better understanding of pulsed liquid-liquid extraction columns was obtained by using an online digital image analysis system to characterize emulsion drop. The mass transfer of acetic acid from dispersed phase (ethyl acetate) to continuous phase (water) was studied under standard conditions. The system enabled drop size distribution (DSD) to be measured as a function of physical and thermodynamic parameters. The surface tension was investigated by static contact angle measurement. Mass transfer and energy transfer, characterized by the surface/volume ratio of the droplets were compared with the working parameters in order to interpret restrictive phenomena such as hold up and column efficiency. The experimental values of Sauter diameter (d(32)) and those predicted by a correlation proposed in the literature are in good agreement. However, the adhesion work between liquid and PTFE plate surface indicates that interface property variations, as a function of solute concentration, must be taken into account in the theoretical correlations. It was found that hold up and separation efficiency depend mainly on the stirring rate. These results show that online image analysis can be used as a process control of a liquid-liquid extraction column in order to optimize the mixing phenomena and the DSD, the key parameter of extraction efficiency. (C) 2010 The Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:60 / 68
页数:9
相关论文
共 50 条
  • [1] Drop size distribution and mean drop size in a pulsed packed extraction column
    Samani, M. Gholam
    Asl, A. Haghighi
    Safdari, J.
    Torab-Mostaedi, M.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2012, 90 (12): : 2148 - 2154
  • [2] Prediction of drop size distribution in a horizontal pulsed plate extraction column
    Khajenoori, M.
    Haghighi-Asl, A.
    Safdari, J.
    Mallah, M. H.
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2015, 92 : 25 - 32
  • [3] Hydrodynamic performance of a pulsed extraction column containing ZnO nanoparticles: Drop size and size distribution
    Amani, Pouria
    Amani, Mohammad
    Saidur, R.
    Yan, Wei-Mon
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2017, 121 : 275 - 286
  • [4] Applying forward mixing model in an L-shape pulsed packed extraction column to investigate the influence of drop size distribution on mass transfer
    Khooshechin, Sajad
    Safdari, Jaber
    Moosavian, Mohammad Ali
    Mallah, Mohammad Hassan
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2019, 145 : 279 - 287
  • [5] Experimental investigation on drop size distribution and mean drop size in an L-shape pulsed packed extraction column
    Khooshechin, Sajad
    Moosavian, Mohamman Ali
    Safdari, Jaber
    Mallah, Mohammad Hassan
    Badakhshan, Hossein
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2022, 179 (462-472): : 462 - 472
  • [6] A STUDY OF MASS TRANSFER IN A PULSED EXTRACTION COLUMN WITH ROTATING FLOW
    DORONIN, VI
    NIKOLAEV, AM
    INTERNATIONAL CHEMICAL ENGINEERING, 1965, 5 (02): : 331 - &
  • [7] Drop-size distribution and average drop size in a Wirz extraction column
    Rincon-Rubio, L.M.
    Kumar, A.
    Hartland, S.
    Chemical Engineering Research and Design, 1994, 72 (A4) : 493 - 502
  • [8] DROP-SIZE DISTRIBUTION AND AVERAGE DROP SIZE IN A WIRZ EXTRACTION COLUMN
    RINCONRUBIO, LM
    KUMAR, A
    HARTLAND, S
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1994, 72 (A4): : 493 - 502
  • [9] EFFECT OF MASS-TRANSFER ON DROPLET SIZE IN A PULSED PACKED EXTRACTION COLUMN
    ROHLFING, E
    HARTMANN, H
    CHEMIE INGENIEUR TECHNIK, 1992, 64 (05) : 470 - 471
  • [10] Parametric study on dispersed phase holdup and axial drop size distribution in a pulsed disc and doughnut extraction column
    Sinha, Vivekananda
    Vincent, Tessy