Reference values for oxygen saturation by pulse oximetry in healthy children at sea level in Chennai

被引:20
|
作者
Balasubramanian, S. [1 ]
Suresh, N. [1 ]
Ravichandran, C. [1 ]
Chand, G. H. Dinesh [1 ]
机构
[1] Kanchi Kamakoti CHILDS Trust Hosp, Madras 600034, Tamil Nadu, India
来源
ANNALS OF TROPICAL PAEDIATRICS | 2006年 / 26卷 / 02期
关键词
D O I
10.1179/146532806X107421
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
There is little information on oxygen saturation (SaO(2)) values in children in developing countries. Aim: To determine the reference values for oxygen saturation by pulse oximetry in healthy children living at sea level in Chennai and aged between 1 mth and 5 yrs. Design and setting: A prospective study was conducted in Kanchi Kamakoti CHILDS Trust Hospital from February to May 2005. Methods: A total of 626 healthy children aged between 1 mth and 5 yrs were examined for heart rate, respiratory rate and SaO(2). Results: The mean SaO(2) levels for children in the age groups 1-3 mths, 3 mths to 1 yr, 1-3 years and 3-5 years were 98.5%, 98.8%, 98.9% and 99.1%, respectively. The overall mean and median SaO(2) values for the children in the different age groups were 99%. The mean -2 SD values of oxygen saturation in the age groups were 96.5%, 96.4%, 96.3% and 97.1%, respectively, with an overall mean of 96.6%. Conclusion: The reference value for mean SaO(2) in healthy children aged between 1 mth and 5 yrs and living at sea level in Chennai city was 98.5% or more, but the -2SD values had a mean of 96.6%.
引用
收藏
页码:95 / 99
页数:5
相关论文
共 50 条
  • [31] Falsely low values of oxygen saturation measured by pulse oximetry in a boy treated with Chinese herb tea
    Meidert, Agnes S.
    Lang, Alexander
    Hennig, Georg
    Bernasconi, Patricia
    Peraud, Aurelia
    Briegel, Josef
    Huettl, Tanija K.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (02) : 481 - 484
  • [32] Fetal pulse oximetry during labor: oxygen saturation values in fetuses with and without umbilical cord complications
    De Morais, EN
    Gallarreta, FMP
    Spara, P
    Gressler, JT
    4TH WORLD CONGRESS OF PERINATAL MEDICINE, 1999, : 135 - 138
  • [33] Falsely low values of oxygen saturation measured by pulse oximetry in a boy treated with Chinese herb tea
    Agnes S. Meidert
    Alexander Lang
    Georg Hennig
    Patricia Bernasconi
    Aurelia Peraud
    Josef Briegel
    Tanija K. Hüttl
    Journal of Clinical Monitoring and Computing, 2017, 31 : 481 - 484
  • [34] PREDICTING CHANGES IN OXYGEN-SATURATION USING PULSE OXIMETRY
    SAPSFORD, DJ
    JONES, JG
    BRITISH JOURNAL OF ANAESTHESIA, 1988, 61 (04) : P497 - P497
  • [35] FETAL OXYGEN-SATURATION MEASUREMENT BY TRANSMISSION PULSE OXIMETRY
    BUSCHMANN, J
    RALL, G
    KNITZA, R
    LANCET, 1992, 339 (8793): : 615 - 615
  • [36] Effect of nail polish and henna on oxygen saturation determined by pulse oximetry in healthy young adult females
    Cicek, Hatice Sutcu
    Gumus, Seyfettin
    Deniz, Omer
    Yildiz, Safak
    Acikel, Cengiz Han
    Cakir, Erdinc
    Tozkoparan, Ergun
    Ucar, Ergun
    Bilgic, Hayati
    EMERGENCY MEDICINE JOURNAL, 2011, 28 (09) : 783 - 785
  • [37] Blood haemoglobin and pulse oximetry oxygen saturation measurement error
    Crooks, C.
    West, J.
    Morling, J.
    Simmonds, M.
    Juurlink, I.
    Briggs, S.
    Cruickshank, S.
    Hammond-Pears, S.
    Shaw, D.
    Card, T.
    Fogarty, A.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [38] TIME TO EQUILIBRATION OF OXYGEN-SATURATION USING PULSE OXIMETRY
    GRUBER, P
    KWIATKOWSKI, T
    SILVERMAN, R
    FLASTER, E
    AUERBACH, C
    ACADEMIC EMERGENCY MEDICINE, 1995, 2 (09) : 810 - 815
  • [39] BIOLOGICAL QUALITY CONTROL FOR PULSE OXIMETRY OXYGEN SATURATION MEASUREMENT
    Back, Geraldine M.
    Dooney, Natalie A.
    Robiony-Rogers, David
    RESPIROLOGY, 2012, 17 : 7 - 7
  • [40] MONITORING OF ARTERIAL OXYGEN-SATURATION BY PULSE OXIMETRY - COMMENT
    SALEM, CJ
    JANDA, A
    BERGER, M
    BRANDSTETTER, A
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1988, 29 (10): : 293 - 293