1D Gamma Counting Approach to Study Radiopharmaceutical Kinetics

被引:0
|
作者
Boisson, F. [1 ]
Bekaert, V. [1 ]
El Bitar, Z. [1 ]
Steibel, J. [1 ]
Huss, D. [1 ]
Brasse, D. [1 ]
机构
[1] IN2P3, CNRS, Inst Pluridisciplinaire Hubert Curien, UMR 7178, F-67037 Strasbourg 02, France
关键词
STRIP DETECTOR; SIMULATION; SYSTEM; SPECT;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Some current researches based on small animal model are dedicated to functional cerebral imaging which represents a fundamental tool to understand the mechanisms involved in neurodegenerative diseases. In the radiopharmaceutical development approach, the main challenge is to measure the radioactivity distribution in the brain of a subject with good temporal and spatial resolutions in order to investigate the behaviors of new radiopharmaceuticals inside the injected subject. In the case where the isotope is a single photon emitter, we present a 1 D gamma counter to investigate the possibility to obtain both high detection efficiency and good spatial resolution to access the kinetic of radiopharmaceutical in the brain of a mouse. The system consists in a 64 channels Multi-Anode PhotoMultiplier Tube (H8804, Hamamatsu Corp.) coupled to a highly segmented YAP:Ce crystal consisting of 32 strips of 0.575 x 18.4 x 10 mm(3). The collimation is made of 33 tungsten slats of 100 mu m thick with a 40 mm height optimized using GEANT4 Monte Carlo simulations. For a field of view of 18.4 x 18.4 mm(2), the intrinsic spatial resolution is equal to 575 mu m with a total detection efficiency of 0.29% for an extended source. The geometry of this new gamma counter gives one kinetic curve per strip to finally get the radiopharmaceutical kinetic in the whole brain of the mouse. To obtain a 2D projection of the brain radioactivity distribution, a spin rotation procedure can be applied. The gamma counter can also be combined to a microCT system to obtain anatomical information.
引用
收藏
页码:4057 / 4061
页数:5
相关论文
共 50 条
  • [1] Kinetics of clustering and acceleration in 1D traffic flow
    Nagatani, T
    [J]. JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1996, 65 (10) : 3386 - 3389
  • [2] 1D Signal Processing for Improvement of People Counting Estimation Results
    Farooq, Sumaiyya
    Khan, Shoab Ahmed
    Akram, M. Usman
    [J]. PROCEEDINGS OF THE 16TH INTERNATIONAL CONFERENCE ON HYBRID INTELLIGENT SYSTEMS (HIS 2016), 2017, 552 : 319 - 328
  • [3] Time-dependent quantum study of the kinetics of the O(1D)+HBr reaction
    Gogtas, Fahrettin
    [J]. CHEMICAL PHYSICS, 2006, 328 (1-3) : 421 - 427
  • [4] Going from 3D to 1D: A 1D approach to common-envelope evolution
    Bronner, V. A.
    Schneider, F. R. N.
    Podsiadlowski, Ph.
    Roepke, F. K.
    [J]. ASTRONOMY & ASTROPHYSICS, 2024, 683
  • [5] BRANCHING RATIO OF GAMMA(1D)-]GAMMA(1S)PI-PI
    KO, P
    [J]. PHYSICAL REVIEW D, 1993, 47 (01): : 208 - 209
  • [6] (1D + 1D) approach mathematical modeling of two phase multicomponent transport flow in PEMFC
    M. Abdollahzadeh
    A. A. Ranjbar
    Q. Esmaili
    [J]. Russian Journal of Electrochemistry, 2012, 48 : 1187 - 1196
  • [7] Hopping kinetics on a finite 1D chain: An exact analysis
    McEwen, J. -S.
    Payne, S. H.
    Kreuzer, H. J.
    Bracher, C.
    [J]. INTERNATIONAL JOURNAL OF QUANTUM CHEMISTRY, 2006, 106 (14) : 2889 - 2903
  • [8] Full Counting Statistics and Large Deviations in a Thermal 1D Bose Gas
    Arzamasovs, Maksims
    Gangardt, Dimitri M.
    [J]. PHYSICAL REVIEW LETTERS, 2019, 122 (12)
  • [9] Full counting statistics of 1d short range Riesz gases in confinement
    Kethepalli, Jitendra
    Kulkarni, Manas
    Kundu, Anupam
    Majumdar, Satya N.
    Mukamel, David
    Schehr, Gregory
    [J]. JOURNAL OF STATISTICAL MECHANICS-THEORY AND EXPERIMENT, 2024, 2024 (08):
  • [10] Analytical approach to 1D bound state problems
    Sindelka, M.
    Eleuch, H.
    Rostovtsev, Y. V.
    [J]. EUROPEAN PHYSICAL JOURNAL D, 2012, 66 (08):