Laboratory Calibration of D-dot Sensor Based on System Identification Method

被引:4
|
作者
Wang, Ke [1 ]
Duan, Yantao [1 ]
Shi, Lihua [1 ]
Qiu, Shi [1 ]
机构
[1] Army Engn Univ PLA, Natl Key Lab Electromagnet Environm Effects & Ele, Nanjing 210007, Jiangsu, Peoples R China
基金
国家重点研发计划;
关键词
electromagnetic pulse measurements; D-dot sensor; system identification; frequency-domain calibration; ELECTROMAGNETIC PULSE; HIGH-VOLTAGE;
D O I
10.3390/s19153255
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
D-dot sensors can realize the non-contact measurement of transient electric fields, which is widely applied to electromagnetic pulse (EMP) measurements with characteristics of the wide frequency band, high linearity, and good stability. In order to achieve accurate calibration of D-dot sensors in the laboratory environment, this paper proposed a new calibration method based on system identification. Firstly, the D-dot sensor can be considered as a linear time-invariant (LTI) system under corner frequency, thus its frequency response can be characterized by the transfer function of a discrete output error (OE) model. Secondly, based on the partial linear regression of the transfer function curve, the sensitivity coefficient of the D-dot sensor is obtained. By increasing the influence weight of low-frequency components, this proposed method has better calibration performance when the waveform is distorted in the time domain, and can artificially adapt to the operating frequency range of the sensor at the same time.
引用
下载
收藏
页数:11
相关论文
共 50 条
  • [21] D-Dot Sensor Response Improvement in the Evaluation of High-Power Microwave Pulses
    Jakubowski, Jacek
    Kuchta, Marek
    Kubacki, Roman
    ELECTRONICS, 2021, 10 (02) : 1 - 10
  • [22] Simulation Test System of Non-Contact D-dot Voltage Transformer
    Yang, Jie
    Wang, Jingang
    Luo, Ruixi
    Gao, Can
    Li Songnong
    Zhou Kongjun
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2016, 17 (02): : 91 - 99
  • [23] Characteristics of the D-Dot Sensor for Measurement of High Voltage Pulse of a Water-Insulated Transmission Line
    Bing, Wei
    Fan, Guo
    Yong, Li
    Yanling, Qing
    Liangji, Zhou
    Weiping, Xie
    IEEE SENSORS JOURNAL, 2023, 23 (03) : 2385 - 2392
  • [24] Online Condition Monitoring of MV Switchgear Using D-Dot Sensor to Predict Arc-Faults
    Hussain, Ghulam Amjad
    Shafiq, Muhammad
    Lehtonen, Matti
    Hashmi, Murtaza
    IEEE SENSORS JOURNAL, 2015, 15 (12) : 7262 - 7272
  • [25] A Calibration Method for Vision Sensor System with 3D Target
    Yang, Xuemei
    Li, Yuan
    Zhao, Kaixin
    2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 6754 - 6759
  • [26] Calibration Method of the 3-D Laser Sensor Measurement System
    Meng, Qing-Xu
    Zhao, Qi-Jie
    Tu, Da-Wei
    Yi, Jin-Gang
    WEARABLE SENSORS AND ROBOTS, 2017, 399 : 123 - 132
  • [27] Principles and experiments of voltage transformer based on self-integrating D-dot probe
    He, Wei
    Luo, Ruixi
    Wang, Jingang
    Ran, Peng
    Wang, Quandi
    Hou, Xingzhe
    Zhou, Kongjun
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2014, 34 (15): : 2445 - 2451
  • [28] Automatic 3D Calibration for a Multi-Sensor System The concept of a 3D calibration method of a radio-based Multi-Sensor System for Indoor Localisation
    Koeppe, Enrico
    Augustin, Daniel
    Liers, Achim
    Schiller, Jochen
    2012 INTERNATIONAL CONFERENCE ON INDOOR POSITIONING AND INDOOR NAVIGATION (IPIN), 2012,
  • [29] Instrument calibration with electromagnetic method based on pseudorandom system identification
    Liu, Lichao
    Ding, Kailai
    Lin, Jun
    Zhou, Fengdao
    Liu, Changsheng
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2014, 35 (08): : 1721 - 1728
  • [30] Decomposition of Composite Electric Field in a Three-Phase D-Dot Voltage Transducer Measuring System
    Hu, Xueqi
    Wang, Jingang
    Wei, Gang
    Deng, Xudong
    SENSORS, 2016, 16 (10)