Calibration Method of the 3-D Laser Sensor Measurement System

被引:0
|
作者
Meng, Qing-Xu [1 ]
Zhao, Qi-Jie [1 ,2 ]
Tu, Da-Wei [1 ,2 ]
Yi, Jin-Gang [3 ]
机构
[1] Shanghai Univ, Sch Mechatron Engn & Automat, Shanghai 200072, Peoples R China
[2] Shanghai Key Lab Intelligent Mfg & Robot, Shanghai 200072, Peoples R China
[3] Rutgers State Univ, Dept Mech & Aerosp Engn, Piscataway, NJ 08854 USA
来源
基金
中国国家自然科学基金;
关键词
Calibration; Laser sensor; Measurement; Structural parameters;
D O I
10.1007/978-981-10-2404-7_11
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to improve the efficiency and adaptability of 3-D laser sensor measurement system, this paper proposed a calibration method based on structural parameters for the 3-D laser sensor measurement system. In this method, by scanning and measuring the structural calibration target with known structural parameters, the models are established in the laser scanning coordinate system and inertial measurement sensor coordinate system respectively, and the linear features are extracted then solve out the relative position and attitude by the constrains of structural parameters. The calibration results are carried out on the 3-D measurement system, which is used to conduct a simulation measurement experiment. In the experiment, the measured results' relative errors of lengths and angles of measured objects are less than 1.0 and 0.5 % on average, which indicate the accuracy of the calibration method. While the noise is increasing, the relative errors keep stability, which indicates the effectiveness of the calibration method.
引用
收藏
页码:123 / 132
页数:10
相关论文
共 50 条
  • [1] A method for the calibration of a 3-D laser scanner
    Niola, Vincenzo
    Rossi, Cesare
    Savino, Sergio
    Strano, Salvatore
    ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2011, 27 (02) : 479 - 484
  • [2] Novel calibration method for 3-D measurement system based on fringe projection
    Chen, MY
    He, HT
    Guo, HW
    Third International Conference on Experimental Mechanics and Third Conference of the Asian-Committee-on-Experimental-Mechanics, Pts 1and 2, 2005, 5852 : 501 - 507
  • [3] Calibration of an anamorphic laser based 3-D range sensor
    Blais, F
    Beraldin, JA
    VIDEOMETRICS V, 1997, 3174 : 113 - 122
  • [4] A rapid calibration method for the laser scanning 3D measurement system
    Xu, Z
    Tao, L
    Sun, C
    Zheng, Y
    MEASUREMENT TECHNOLOGY AND INTELLIGENT INSTRUMENTS VI, 2005, 295-296 : 735 - 740
  • [5] A calibration method of line laser 3D gear measurement system
    Shi, Zhaoyao (shizhaoyao@bjut.edu.cn), 2025, 242
  • [6] A Calibration and 3-D Measurement Method for an Active Vision System With Symmetric Yawing Cameras
    Xu, De
    Zhang, Di
    Liu, Xilong
    Ma, Liping
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [7] Comment about the calibration method of ILRIS36D 3-D laser scanning system
    Luo, Xu
    Cheng, Chengqi
    Deng, Xiangrui
    Chen, Xiaoxue
    Feng, Zhongke
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2008, 29 (SUPPL.): : 26 - 30
  • [8] A Comprehensive Method for Magnetic Sensor Calibration: A Precise System for 3-D Tracking of the Tongue Movements
    Farajidavar, Aydin
    Block, Jacob M.
    Ghovanloo, Maysam
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 1153 - 1156
  • [9] Calibration of a High-Accuracy 3-D Coordinate Measurement Sensor Based on Laser Beam and CMOS Camera
    Lazaro Galilea, Jose Luis
    Lavest, Jean-Marc
    Luna Vazquez, Carlos Andres
    Gardel Vicente, Alfredo
    Bravo Munoz, Ignacio
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (09) : 3341 - 3346
  • [10] Building an Omnidirectional 3-D Color Laser Ranging System Through a Novel Calibration Method
    An, Yi
    Li, Bo
    Hu, Huosheng
    Zhou, Xiaoli
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (11) : 8821 - 8831