Calibration Method of the 3-D Laser Sensor Measurement System

被引:0
|
作者
Meng, Qing-Xu [1 ]
Zhao, Qi-Jie [1 ,2 ]
Tu, Da-Wei [1 ,2 ]
Yi, Jin-Gang [3 ]
机构
[1] Shanghai Univ, Sch Mechatron Engn & Automat, Shanghai 200072, Peoples R China
[2] Shanghai Key Lab Intelligent Mfg & Robot, Shanghai 200072, Peoples R China
[3] Rutgers State Univ, Dept Mech & Aerosp Engn, Piscataway, NJ 08854 USA
来源
基金
中国国家自然科学基金;
关键词
Calibration; Laser sensor; Measurement; Structural parameters;
D O I
10.1007/978-981-10-2404-7_11
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to improve the efficiency and adaptability of 3-D laser sensor measurement system, this paper proposed a calibration method based on structural parameters for the 3-D laser sensor measurement system. In this method, by scanning and measuring the structural calibration target with known structural parameters, the models are established in the laser scanning coordinate system and inertial measurement sensor coordinate system respectively, and the linear features are extracted then solve out the relative position and attitude by the constrains of structural parameters. The calibration results are carried out on the 3-D measurement system, which is used to conduct a simulation measurement experiment. In the experiment, the measured results' relative errors of lengths and angles of measured objects are less than 1.0 and 0.5 % on average, which indicate the accuracy of the calibration method. While the noise is increasing, the relative errors keep stability, which indicates the effectiveness of the calibration method.
引用
收藏
页码:123 / 132
页数:10
相关论文
共 50 条
  • [41] 3-D laser cutting system
    不详
    MANUFACTURING ENGINEERING, 2005, 134 (05): : 59 - 60
  • [42] OBJECTIVE LASER SPECKLE METHOD FOR 3-D DISPLACEMENT MEASUREMENT ON CURVED SURFACES
    KIN, CC
    CHIANG, FP
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1982, 335 : 54 - 58
  • [43] 3-D visual measurement method using rotary vision system
    Hata, S
    Shima, D
    Hayashi, J
    Higashi, N
    Kaida, K
    PROCEEDINGS OF THE 2004 INTERNATIONAL CONFERENCE ON INTELLIGENT MECHATRONICS AND AUTOMATION, 2004, : 532 - 535
  • [44] A novel temporal calibration method for 3-D ultrasound
    Rousseau, Francois
    Hellier, Pierre
    Barillot, Christian
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (08) : 1108 - 1112
  • [45] High-speed 3-D measurement system using smart image sensor and FPGA based 3-D engine
    Yachide, Yusuke
    Ikeda, Makoto
    Asada, Kunihiro
    2006 13TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS 1-3, 2006, : 764 - 767
  • [46] Research on 3-D Real-time Measurement System of Seam with Laser
    Huang Min-shuang
    Huang Jun-fen
    Tang Jian
    Jiang Li-pei
    2013 FIFTH INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION (ICMTMA 2013), 2013, : 870 - 874
  • [47] 3-D Shape Measurement Sensor for Specular Objects
    Kagawa Prefectural Industrial Technology Center, 587-1 Goto-cho, Kagawa, Takamatsu
    761, Japan
    不详
    760, Japan
    Journal of Robotics and Mechatronics, 1995, 7 (03): : 221 - 224
  • [48] A 3-D measurement method with orthogonal composite light based on fringe contrast and background calibration
    He Y.
    Cao Y.
    Zhai A.
    Guangxue Xuebao/Acta Optica Sinica, 2010, 30 (11): : 3191 - 3196
  • [49] Calibration of the 3-D Coil System's Orthogonality
    Zikmund, A.
    Ripka, P.
    IEEE TRANSACTIONS ON MAGNETICS, 2013, 49 (01) : 66 - 68
  • [50] Calibration of a 3-D surface contouring and ranging system
    Hu, QY
    Huang, PSS
    Fu, QL
    Chiang, FP
    THREE-DIMENSIONAL IMAGING, OPTICAL METROLOGY, AND INSPECTION V, 1999, 3835 : 158 - 166