LTS SQUID gradiometer system for in vivo magnetorelaxometry

被引:8
|
作者
Warzemann, L
Schambach, J
Weber, P
Weitschies, W
Kötitz, R
机构
[1] Univ Jena, D-07743 Jena, Germany
[2] Inst Diagnostikforsch GmbH Berlin, D-14050 Berlin, Germany
来源
SUPERCONDUCTOR SCIENCE & TECHNOLOGY | 1999年 / 12卷 / 11期
关键词
D O I
10.1088/0953-2048/12/11/377
中图分类号
O59 [应用物理学];
学科分类号
摘要
A system for spatially resolved magnetorelaxometry in spatially expanded objects (e.g. for in vivo investigations) in a disturbed environment is presented. The system is based on an LTS SQUID gradiometer with a field gradient sensitivity of 30 fT cm(-1) Hz(-1/2) and an intrinsic balance of some 10(-5). A Helmholtz coil of 80 cm diameter allows the magnetization of the samples with fields up to 7 mT. A nonmagnetic x-y stage (driven by step motors) covers a scanning area of 40 cm x 25 cm. We present spatially resolved measurements of the Neel relaxation of samples (dried ferrofluid) and compare them with model calculations. The data acquisition and monitoring as well as the filtering and fitting procedure are discussed.
引用
收藏
页码:953 / 955
页数:3
相关论文
共 50 条
  • [41] INTEGRATED GRADIOMETER WITH LARGE BETA-SQUID
    YOSHIDA, K
    KOHJIRO, S
    ENPUKU, K
    YAMAFUJI, K
    IEEE TRANSACTIONS ON MAGNETICS, 1987, 23 (02) : 1106 - 1109
  • [42] Integrated SQUID-gradiometer system for magneto- cardiography without magnetic shielding
    Stolz, R
    Zakosarenko, V
    Bondarenko, N
    Schulz, M
    Fritzsch, L
    Oukhanski, N
    Meyer, HG
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) : 356 - 359
  • [43] A high temperature superconductor dc SQUID planar gradiometer measurement system for routine inspections
    Faley, MI
    Poppe, U
    Slobodchikov, VY
    Maslennikov, YV
    Urban, K
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2004, 17 (05): : S301 - S304
  • [44] Peripheral nerve conduction recorded by a micro gradiometer system (micro-SQUID) in humans
    Hoshiyama, M
    Kakigi, R
    Nagata, O
    NEUROSCIENCE LETTERS, 1999, 272 (03) : 199 - 202
  • [45] Actively shielded, adaptively balanced SQUID gradiometer system for operation aboard moving platforms
    Keene, MN
    Humphrey, KP
    Horton, TJ
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) : 761 - 764
  • [46] Construction and test of a cryocooler-cooled low-Tc SQUID gradiometer system
    Rijpma, Ar
    Krooshoop, H. J. G.
    Lefevere, M. W.
    Van Leeuwen, E. P.
    Holland, H. J.
    ten Haken, B.
    Ter Brake, H. J. M.
    CRYOGENICS, 2008, 48 (1-2) : 61 - 67
  • [47] Integrated LTS gradiometer SQUIDs for measurements of magnetic field distributions in an unshielded environment
    Stolz, R
    Schultze, V
    Zakosarenko, VM
    Fritzsch, L
    Meyer, HG
    CZECHOSLOVAK JOURNAL OF PHYSICS, 1996, 46 : 2769 - 2770
  • [48] A niobium planar SQUID gradiometer operating in an unshielded environment
    Bar, LR
    Daalmans, GM
    Uhl, D
    Bommel, F
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1996, 9 (4A): : A109 - A111
  • [49] GRADIOMETER BASED ON 2 SINGLE-HOLE SQUID
    LIKHACHEV, AG
    POLUSHKIN, VN
    UCHAIKIN, SV
    VASILIEV, BV
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1990, 39 (06) : 1034 - 1037
  • [50] A SQUID gradiometer module with large junction shunt resistors
    邱阳
    刘超
    张树林
    张国峰
    王永良
    李华
    曾佳
    孔祥燕
    谢晓明
    Chinese Physics B, 2014, 23 (08) : 626 - 628