LTS SQUID gradiometer system for in vivo magnetorelaxometry

被引:8
|
作者
Warzemann, L
Schambach, J
Weber, P
Weitschies, W
Kötitz, R
机构
[1] Univ Jena, D-07743 Jena, Germany
[2] Inst Diagnostikforsch GmbH Berlin, D-14050 Berlin, Germany
来源
SUPERCONDUCTOR SCIENCE & TECHNOLOGY | 1999年 / 12卷 / 11期
关键词
D O I
10.1088/0953-2048/12/11/377
中图分类号
O59 [应用物理学];
学科分类号
摘要
A system for spatially resolved magnetorelaxometry in spatially expanded objects (e.g. for in vivo investigations) in a disturbed environment is presented. The system is based on an LTS SQUID gradiometer with a field gradient sensitivity of 30 fT cm(-1) Hz(-1/2) and an intrinsic balance of some 10(-5). A Helmholtz coil of 80 cm diameter allows the magnetization of the samples with fields up to 7 mT. A nonmagnetic x-y stage (driven by step motors) covers a scanning area of 40 cm x 25 cm. We present spatially resolved measurements of the Neel relaxation of samples (dried ferrofluid) and compare them with model calculations. The data acquisition and monitoring as well as the filtering and fitting procedure are discussed.
引用
收藏
页码:953 / 955
页数:3
相关论文
共 50 条
  • [21] COMPACT INTEGRATED DC SQUID GRADIOMETER
    DEWAAL, VJ
    KLAPWIJK, TM
    APPLIED PHYSICS LETTERS, 1982, 41 (07) : 669 - 671
  • [22] Factors Affecting the Performance of a SQUID Gradiometer
    Baltag, Octavian
    Rau, Miuta Carmina
    2015 9TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE), 2015, : 953 - 956
  • [23] Baseline optimization of SQUID gradiometer for magnetocardiography
    Li Hua
    Zhang Shu-Lin
    Qiu Yang
    Zhang Yong-Sheng
    Zhang Chao-Xiang
    Kong Xiang-Yan
    Xie Xiao-Ming
    CHINESE PHYSICS B, 2015, 24 (02)
  • [24] A 24-SQUID GRADIOMETER FOR MAGNETOENCEPHALOGRAPHY
    AHLFORS, S
    AHONEN, A
    EHNHOLM, G
    HAMALAINEN, M
    ILMONIEMI, R
    KAJOLA, M
    KIVIRANTA, M
    KNUUTILA, J
    LOUNASMAA, O
    SIMOLA, J
    TESCHE, C
    VILKMAN, V
    PHYSICA B, 1990, 165 : 97 - 98
  • [25] 24-SQUID gradiometer for magnetoencephalography
    Ahlfors, S.
    Ahonen, A.
    Ehnholm, G.
    Haemaelaeinen, M.
    Ilmoniemi, R.
    Kajola, M.
    Kiviranta, M.
    Knuutila, J.
    Lounasmaa, O.V.
    Simola, J.
    Tesche, C.
    Vilkman, V.
    Physica B: Condensed Matter, 1990, 165-66 (01) : 97 - 98
  • [26] A Non-Destructive Beam Monitoring System Based on an LTS-SQUID
    Geithner, R.
    Neubert, R.
    Vodel, W.
    Schwickert, M.
    Reeg, H.
    von Hahn, R.
    Seidel, P.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 444 - 447
  • [27] A LTS-SQUID system for archaeological prospection and its practical test in Peru
    Linzen, S.
    Chwala, A.
    Schultze, V.
    Schulz, M.
    Schueler, T.
    Stolz, R.
    Bondarenko, N.
    Meyer, H.-G.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) : 750 - 755
  • [28] Aircraft wheel testing with machine-cooled HTS SQUID gradiometer system
    Hohmann, R
    Maus, M
    Lomparski, D
    Grüneklee, M
    Zhang, Y
    Krause, HJ
    Bousack, H
    Braginski, AI
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 3801 - 3804
  • [29] Eddy current aircraft testing with mobile HTS-SQUID gradiometer system
    Krause, HJ
    Zhang, Y
    Hohmann, R
    Gruneklee, M
    Faley, MI
    Lomparski, D
    Maus, M
    Bousack, H
    Braginski, AI
    APPLIED SUPERCONDUCTIVITY 1997, VOLS 1 AND 2: VOL 1: SMALL SCALE AND ELECTRONIC APPLICATIONS; VOL 2: LARGE SCALE AND POWER APPLICATIONS, 1997, (158): : 775 - 780
  • [30] LTS SQUID microscope with micron spatial resolution
    Anderberg, J
    Colclough, MS
    Crum, DB
    Tokura, Y
    Paulson, DN
    Fagaly, RL
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) : 231 - 234