Axial compressive behavior of square concrete columns reinforced with innovative closed-type winding GFRP stirrups

被引:64
|
作者
Dong, Heng-Lei [1 ,2 ,3 ]
Wang, Daiyu [1 ,2 ,3 ]
Wang, Zhenyu [1 ,2 ,3 ]
Sun, Yunlong [4 ]
机构
[1] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Heilongjiang, Peoples R China
[2] Harbin Inst Technol, Minist Ind & Informat Technol, Key Lab Smart Prevent & Mitigat Civil Engn Disast, Harbin 150090, Heilongjiang, Peoples R China
[3] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Heilongjiang, Peoples R China
[4] Harbin FRP Inst, Harbin 150000, Heilongjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
FRP; Concrete columns; Axial compression; Confinement efficiency; Stirrups; FRP; BEAMS; DESIGN; STEEL; MODEL;
D O I
10.1016/j.compstruct.2018.02.092
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Conventional fiber-reinforced polymer (FRP) rod stirrups are characterized by at least one side overlap, where premature bond slip failure is likely to occur, resulting in low confinement efficiency. To overcome this shortcoming, an innovative closed-type winding glass FRP (CW-GFRP) stirrup was proposed by winding continuous filaments on the mould. This paper also presented an experimental study on the axial compressive behavior of 16 large-scale columns (300 x 300 x 900 mm), which were reinforced longitudinally with identical steel bars and transversely with different stirrups, namely steel, CW-GFRP or conventional GFRP rod stirrups. The confinement efficiency of these stirrups was compared regarding the failure modes, axial load capacity and ultimate axial strain. Test results indicated that columns reinforced with conventional GFRP rod stirrups exhibited bond slip failure after spalling of concrete cover, while CW-GFRP confined columns avoided this failure. The proposed CW-GFRP stirrups performed best in improving the ductility of columns. When stirrup spacing was 75 mm, an increase of 95% and 180% in ultimate axial strain was achieved for CW-GFRP confined columns compared with their steel and GFRP rod stirrup counterparts. Columns with CW-GFRP stirrups spaced at 50 mm exhibited monotonically ascending load-strain responses and achieved the ultimate strain up to 5.51%.
引用
收藏
页码:115 / 125
页数:11
相关论文
共 50 条
  • [31] Experimental and numerical studies on compressive behavior of winding FRP grid spiral stirrups confined circular concrete columns
    Chen, Chen
    Fang, Hai
    Lim, Yun Mook
    Xie, Honglei
    Chen, Jiye
    Park, Ji Woon
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2025, 191
  • [32] Experimental study on the behavior of GFRP reinforced concrete columns under eccentric axial load
    Sun, Li
    Wei, Minghai
    Zhang, Na
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 152 : 214 - 225
  • [33] Experimental study and finite element analysis of concrete columns with square GFRP tube confined cross stirrups under axial compression
    Yongyao Zhang
    Yunfeng Zhang
    Zhenchao Teng
    Yi Zhao
    Tong Wang
    Wenbin Zhang
    Discover Civil Engineering, 1 (1):
  • [34] Shear Behavior of Steel or GFRP Reinforced Concrete Beams Without Stirrups
    Kotynia, Renata
    Kaszubska, Monika
    Barros, Joaquim A. O.
    HIGH TECH CONCRETE: WHERE TECHNOLOGY AND ENGINEERING MEET, 2018, : 769 - 777
  • [35] Axial compressive behavior of corroded reinforced concrete columns strengthened by fiber reinforced polymer composite
    Yu A.
    Li C.
    Gao D.
    Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2018, 35 (05): : 1315 - 1324
  • [36] Axial compressive behavior of square steel tube confined rubberized concrete stub columns
    Yang Zhaoyuan
    Qiao Qiyun
    Cao Wanlin
    Gao Xiaopeng
    JOURNAL OF BUILDING ENGINEERING, 2022, 52
  • [37] Compressive behavior of axially loaded circular hollow concrete columns reinforced with GFRP bars and spirals
    AlAjarmeh, O. S.
    Manalo, A. C.
    Benmokrane, B.
    Karunasena, W.
    Mendis, P.
    Nguyen, K. T. Q.
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 194 : 12 - 23
  • [38] Rectangular seawater sea-sand concrete columns using steel-FRP composite bars and closed-type winding FRP ties: Axial behavior and confinement model
    Xiao, Gang
    Tan, Wei
    Han, Shiwen
    Mai, Peirong
    Ou, Jinping
    COMPOSITE STRUCTURES, 2025, 354
  • [39] PERFORMANCE OF SQUARE REINFORCED CONCRETE COLUMNS CONFINED WITH INNOVATIVE CONFINING SYSTEM UNDER AXIAL COMPRESSION
    Machmoed, Soerjandani Priantoro
    Tavio
    Raka, I. Gusti Putu
    INTERNATIONAL JOURNAL OF GEOMATE, 2021, 21 (85): : 137 - 144
  • [40] Structural Behavior of Circular Concrete Columns Reinforced with Longitudinal GFRP Rebars under Axial Load
    Sajedi, Seyed Fathollah
    Saffarian, Iman
    Pourbaba, Masoud
    Yeon, Jung Heum
    BUILDINGS, 2024, 14 (04)