Axial compressive behavior of square concrete columns reinforced with innovative closed-type winding GFRP stirrups

被引:64
|
作者
Dong, Heng-Lei [1 ,2 ,3 ]
Wang, Daiyu [1 ,2 ,3 ]
Wang, Zhenyu [1 ,2 ,3 ]
Sun, Yunlong [4 ]
机构
[1] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Heilongjiang, Peoples R China
[2] Harbin Inst Technol, Minist Ind & Informat Technol, Key Lab Smart Prevent & Mitigat Civil Engn Disast, Harbin 150090, Heilongjiang, Peoples R China
[3] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Heilongjiang, Peoples R China
[4] Harbin FRP Inst, Harbin 150000, Heilongjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
FRP; Concrete columns; Axial compression; Confinement efficiency; Stirrups; FRP; BEAMS; DESIGN; STEEL; MODEL;
D O I
10.1016/j.compstruct.2018.02.092
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Conventional fiber-reinforced polymer (FRP) rod stirrups are characterized by at least one side overlap, where premature bond slip failure is likely to occur, resulting in low confinement efficiency. To overcome this shortcoming, an innovative closed-type winding glass FRP (CW-GFRP) stirrup was proposed by winding continuous filaments on the mould. This paper also presented an experimental study on the axial compressive behavior of 16 large-scale columns (300 x 300 x 900 mm), which were reinforced longitudinally with identical steel bars and transversely with different stirrups, namely steel, CW-GFRP or conventional GFRP rod stirrups. The confinement efficiency of these stirrups was compared regarding the failure modes, axial load capacity and ultimate axial strain. Test results indicated that columns reinforced with conventional GFRP rod stirrups exhibited bond slip failure after spalling of concrete cover, while CW-GFRP confined columns avoided this failure. The proposed CW-GFRP stirrups performed best in improving the ductility of columns. When stirrup spacing was 75 mm, an increase of 95% and 180% in ultimate axial strain was achieved for CW-GFRP confined columns compared with their steel and GFRP rod stirrup counterparts. Columns with CW-GFRP stirrups spaced at 50 mm exhibited monotonically ascending load-strain responses and achieved the ultimate strain up to 5.51%.
引用
收藏
页码:115 / 125
页数:11
相关论文
共 50 条
  • [21] Effect of Axial Compression Ratio on Seismic Behavior of GFRP Reinforced Concrete Columns
    Sun, Li
    Yang, Zeyu
    Jin, Qiao
    Yan, Weidong
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2020, 20 (06)
  • [22] Axial compressive behavior of concrete-encased CFST stub columns with open composite stirrups
    Ke, Xiaojun
    Ding, Wen
    Liao, Dingguo
    ADVANCES IN CONCRETE CONSTRUCTION, 2021, 12 (05) : 399 - 409
  • [23] Shear behavior of circular concrete short columns reinforced with GFRP longitudinal bars and CFRP grid stirrups
    Liao, JinJing
    Di, Bo
    Zheng, Yu
    Xuan, Zhi-Wen
    Zeng, Jun-Jie
    COMPOSITE STRUCTURES, 2024, 340
  • [24] Axial compressive behavior of steel fiber reinforced concrete-filled square steel tube stub columns
    Liu, Zhenzhen
    Huang, Dongming
    Wu, Haozhou
    Lu, Yiyan
    Luo, Xi
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 203
  • [25] Analytical study on axial compression-Bending interaction behavior of fiber reinforced square concrete columns with GFRP rebars
    Balaji, G. R.
    Patil, Ganapati M.
    Prakash, S. Suriya
    STRUCTURAL CONCRETE, 2024,
  • [26] Effect of spiral spacing on axial compressive behavior of square reinforced concrete filled steel tube (RCFST) columns
    Qiao, Qiyun
    Zhang, Wenwen
    Mou, Ben
    Cao, Wanlin
    STEEL AND COMPOSITE STRUCTURES, 2019, 31 (06): : 559 - 573
  • [27] Behavior of Slender GFRP Reinforced Concrete Columns
    Khorramian, Koosha
    Sadeghian, Pedram
    STRUCTURES CONGRESS 2019: BRIDGES, NONBUILDING AND SPECIAL STRUCTURES, AND NONSTRUCTURAL COMPONENTS, 2019, : 88 - 99
  • [28] Compressive and Bonding Performance of GFRP-Reinforced Concrete Columns
    Alsuhaibani, Eyad
    Alturki, Mansour
    Alogla, Saleh M.
    Alawad, Omar
    Alkharisi, Mohammed K.
    Bayoumi, Elsaid
    Aldukail, Ali
    BUILDINGS, 2024, 14 (04)
  • [29] Axial load-bending moment diagrams of GFRP reinforced columns and GFRP encased square columns
    Youssef, Jim
    Hadi, Muhammad N. S.
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 135 : 550 - 564
  • [30] Axial Compressive Behavior of Glass Fiber-Reinforced Hollow Concrete Columns
    Jian, Xiangyang
    Zhang, Ni
    Sun, Qingwei
    Liu, Jian
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2022, 2022