Axial compressive behavior of square concrete columns reinforced with innovative closed-type winding GFRP stirrups

被引:64
|
作者
Dong, Heng-Lei [1 ,2 ,3 ]
Wang, Daiyu [1 ,2 ,3 ]
Wang, Zhenyu [1 ,2 ,3 ]
Sun, Yunlong [4 ]
机构
[1] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Heilongjiang, Peoples R China
[2] Harbin Inst Technol, Minist Ind & Informat Technol, Key Lab Smart Prevent & Mitigat Civil Engn Disast, Harbin 150090, Heilongjiang, Peoples R China
[3] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Heilongjiang, Peoples R China
[4] Harbin FRP Inst, Harbin 150000, Heilongjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
FRP; Concrete columns; Axial compression; Confinement efficiency; Stirrups; FRP; BEAMS; DESIGN; STEEL; MODEL;
D O I
10.1016/j.compstruct.2018.02.092
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Conventional fiber-reinforced polymer (FRP) rod stirrups are characterized by at least one side overlap, where premature bond slip failure is likely to occur, resulting in low confinement efficiency. To overcome this shortcoming, an innovative closed-type winding glass FRP (CW-GFRP) stirrup was proposed by winding continuous filaments on the mould. This paper also presented an experimental study on the axial compressive behavior of 16 large-scale columns (300 x 300 x 900 mm), which were reinforced longitudinally with identical steel bars and transversely with different stirrups, namely steel, CW-GFRP or conventional GFRP rod stirrups. The confinement efficiency of these stirrups was compared regarding the failure modes, axial load capacity and ultimate axial strain. Test results indicated that columns reinforced with conventional GFRP rod stirrups exhibited bond slip failure after spalling of concrete cover, while CW-GFRP confined columns avoided this failure. The proposed CW-GFRP stirrups performed best in improving the ductility of columns. When stirrup spacing was 75 mm, an increase of 95% and 180% in ultimate axial strain was achieved for CW-GFRP confined columns compared with their steel and GFRP rod stirrup counterparts. Columns with CW-GFRP stirrups spaced at 50 mm exhibited monotonically ascending load-strain responses and achieved the ultimate strain up to 5.51%.
引用
收藏
页码:115 / 125
页数:11
相关论文
共 50 条
  • [1] Axial compression behavior of seawater sea-sand concrete columns reinforced with SFCBs and closed-type winding GFRP ties
    Xiao, Gang
    Tan, Wei
    Han, Shiwen
    Mai, Peirong
    Fan, Chao
    Ou, Jinping
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 416
  • [2] Axial compressive behavior of square reinforced concrete columns confined using two layers of stirrups
    Wu, Dong-Yan
    Sun, Lin-Zhu
    Yang, Fang
    Zhao, Jun-Liang
    Li, Wei
    ADVANCES IN STRUCTURAL ENGINEERING, 2016, 19 (08) : 1345 - 1356
  • [3] Shear behavior of concrete beams reinforced with closed-type winding glass fiber-reinforced polymer stirrups
    Yuan, Ye
    Wang, Zhenyu
    Wang, Daiyu
    ADVANCES IN STRUCTURAL ENGINEERING, 2022, 25 (12) : 2577 - 2589
  • [4] Axial compressive behavior of square steel tubular columns filled with steel stirrups reinforced recycled lump concrete
    Zang, Jian-Bo
    Wu, Bo
    STRUCTURES, 2022, 36 : 735 - 751
  • [5] Axial compressive behavior of GFRP-timber-reinforced concrete composite columns
    Fubin Zhang
    Hu Luo
    Jianzhuang Xiao
    Amardeep Singh
    Jing Xu
    Hai Fang
    Low-carbon Materials and Green Construction, 1 (1):
  • [6] Axial compressive behaviour of GFRP tube reinforced concrete columns
    Hadi, Muhammad N. S.
    Wang, Weiqiang
    Sheikh, M. Neaz
    CONSTRUCTION AND BUILDING MATERIALS, 2015, 81 : 198 - 207
  • [7] Experimental study on the shear performance of concrete beams reinforced with new type closed winding GFRP stirrups
    Yuan Y.
    Wang Z.
    Wang D.
    Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2022, 39 (11): : 5074 - 5085
  • [8] Behavior and Performance of GFRP Reinforced Concrete Columns with Various Types of Stirrups
    Prachasaree, Woraphot
    Piriyakootorn, Sitthichai
    Sangsrijun, Athawit
    Limkatanyu, Suchart
    INTERNATIONAL JOURNAL OF POLYMER SCIENCE, 2015, 2015
  • [9] Axial Behavior of Square Reinforced Concrete Columns Strengthened with Lightweight Concrete Elements and Unbonded GFRP Wrapping
    Herwig, Andrin
    Motavalli, Masoud
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2012, 16 (06) : 747 - 752
  • [10] Axial monotonic and cyclic compressive behavior of square GFRP tube-confined steel-reinforced concrete composite columns
    Pei, Weichang
    Wang, Daiyu
    Wang, Xuan
    Wang, Zhenyu
    ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (01) : 25 - 41