Experimental Investigation Toward an SMA Retrofitting Application

被引:0
|
作者
AlSaleh, R. [1 ]
Casciati, F. [1 ]
El-Attar, A.
El-Habbal, I.
机构
[1] Univ Pavia, Dept Struct Mech, I-27100 Pavia, Italy
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The positions where minarets are mostly built in the urban nuclei made the failure of such structures more severe. Their structural weakness could results in failures with heavy consequences. But the retrofit solutions are limited by their simple cantilever scheme. The use of metallic pre-stressed wires/cables is a rather consolidated technique. The use of shape memory alloy (SMA) wires was recently investigated. In view of such an application, a series of reduced scale tests was planned and realized. This paper synthesizes a full report on the achieved results from an experimental work on a SDOF model subjected to free vibration before and after being retrofitted with SMA wires. The results proved an enhancement imparted to the system in terms of the stiffness when equipped with SMA wires. The effect on damping is also discussed.
引用
收藏
页码:1116 / 1123
页数:8
相关论文
共 50 条
  • [31] Passive Attenuation of Mechanical Vibrations with a Superelastic SMA Bending Springs: An Experimental Investigation
    Senko, Richard
    Almeida, Vinicius S.
    dos Reis, Romulo P. B.
    Oliveira, Andersson G.
    Silva, Antonio A.
    Rodrigues, Marcelo C.
    de Carvalho, Laura H.
    Lima, Antonio G. B.
    SENSORS, 2022, 22 (09)
  • [32] Retrofitting of a damaged liquid storage tank using steel and SMA anchor bolts
    Najmabad, Saeid Jamalpour
    Razzaghi, Mehran Seyed
    Alahi, Fariborz Nateghi
    INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2021, 194
  • [33] Analysis on the Applications of Novel SMA Damper in Seismic Retrofitting of One Teaching Building
    Ling, Yu Hong
    Ling, Hong Hua
    Wu, Jing Zhuang
    Chan Yuan Huang-fu
    VIBRATION, STRUCTURAL ENGINEERING AND MEASUREMENT I, PTS 1-3, 2012, 105-107 : 1020 - +
  • [34] Application of trained NiTi SMA actuators in a spatial compliant mechanism: Experimental investigations
    Sreekumar, M.
    Nagarajan, T.
    Singaperumal, M.
    MATERIALS & DESIGN, 2009, 30 (08) : 3020 - 3029
  • [35] Experimental and numerical investigation of seismic retrofitting of RC square short columns using FRP composites
    Kargaran, Ali
    Kheyroddin, Ali
    EUROPEAN JOURNAL OF ENVIRONMENTAL AND CIVIL ENGINEERING, 2022, 26 (10) : 4619 - 4642
  • [36] Effect of retrofitting strong beam and weak column exterior joint using HPHFRC: Experimental investigation
    Mohinderu, Kunal
    Bansal, Prem Pal
    Pandey, Dhirendra K.
    ENGINEERING STRUCTURES, 2025, 332
  • [37] Solar Pond Window Technology for Energy-Efficient Retrofitting of Buildings: An Experimental and Numerical Investigation
    Erdem Cuce
    Pinar Mert Cuce
    Arabian Journal for Science and Engineering, 2017, 42 : 1909 - 1916
  • [38] Solar Pond Window Technology for Energy-Efficient Retrofitting of Buildings: An Experimental and Numerical Investigation
    Cuce, Erdem
    Cuce, Pinar Mert
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2017, 42 (05) : 1909 - 1916
  • [39] Experimental investigation of retrofitting seismically damaged reinforced-concrete frames using steel jacketing
    Chong, Xun
    Liu, Hualong
    Xie, Linlin
    Zhou, An
    Huang, Junqi
    Sha, Huiling
    STRUCTURES, 2024, 62
  • [40] APPLICATION OF ACTIVATION RADIOGRAPHY IN EXPERIMENTAL INVESTIGATION
    FLITSIYAN, ES
    RADIATION MEASUREMENTS, 1995, 25 (1-4) : 367 - 372