Analysis on the Applications of Novel SMA Damper in Seismic Retrofitting of One Teaching Building

被引:0
|
作者
Ling, Yu Hong [1 ]
Ling, Hong Hua [1 ]
Wu, Jing Zhuang [2 ]
Chan Yuan Huang-fu [2 ]
机构
[1] S China Univ Technol, Architecture Design Inst, Guangzhou 510640, Peoples R China
[2] S China Univ Technol, Dept Civil Engn, Guangzhou 510640, Guangdong, Peoples R China
关键词
Re-centring damper; Optimal layout; Damping effect; Time-history analysis;
D O I
10.4028/www.scientific.net/AMM.105-107.1020
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
According to one three-story RC frame structure, the results of time-history analysis of using re-centring SMA damper to seismic retrofitting are introduced in detail. Damping effect of dampers is studied by index such as floor displacement, story drift, story shear force, energy dissipation, etc., and optimal layout of dampers is also discussed. The analysis results indicate that floor displacement and story drift are decreased greatly after strengthening, and story shear force is controlled to some extent with good effect. The damper dissipates most of the total energy inputting into structure and also has good ability to re-centring. The damper can obtain good energy dissipation when arranged at the maximum story drift, and less energy dissipation when arranged at the smaller story drift.
引用
收藏
页码:1020 / +
页数:2
相关论文
共 47 条
  • [1] Proposed SMA Tension Sling Damper for Passive Seismic Control of Building
    Mehta, S.H.
    Purohit, S.P.
    Electronic Journal of Structural Engineering, 2019, 19 (01): : 49 - 59
  • [2] Proposed SMA Tension Sling Damper for Passive Seismic Control of Building
    Mehta, S. H.
    Purohit, S. P.
    ELECTRONIC JOURNAL OF STRUCTURAL ENGINEERING, 2019, 19 : 49 - 59
  • [3] Design of SMA Damper and Analysis on Seismic Control of Frame Structure
    Xing, Dejin
    Yang, Baoquan
    Wang, Mingdong
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 2584 - +
  • [4] Analysis and seismic retrofitting of unreinforced masonry building: a case study
    Aziz I.
    Ahsan R.
    Sakib M.S.
    Aziz S.
    Islam M.A.
    Ansary M.A.
    Asian Journal of Civil Engineering, 2021, 22 (3) : 443 - 460
  • [5] Seismic Assessment of a School Building in Nepal and Analysis of Retrofitting Solutions
    Rodrigues, Hugo
    Furtado, Andre
    Vila-Pouca, Nelson
    Varum, Humberto
    Barbosa, Andre R.
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2018, 16 (11A) : 1573 - 1589
  • [6] Seismic Assessment of a School Building in Nepal and Analysis of Retrofitting Solutions
    Hugo Rodrigues
    André Furtado
    Nelson Vila-Pouca
    Humberto Varum
    André R. Barbosa
    International Journal of Civil Engineering, 2018, 16 : 1573 - 1589
  • [7] An enhanced-deformability SMA damper: Experimental tests and seismic control analysis
    Liu, Jiawang
    Huang, Tianyi
    Qiu, Canxing
    Cheng, Lizi
    Du, Xiuli
    Liu, Hang
    ENGINEERING STRUCTURES, 2025, 325
  • [8] Control effect of large tuned mass damper used for seismic retrofitting of existing high-rise building
    Nakai, Takeshi
    Kurino, Haruhiko
    Yaguchi, Tomoki
    Kano, Naoki
    JAPAN ARCHITECTURAL REVIEW, 2019, 2 (03) : 269 - 286
  • [9] Finite-element analysis for seismic response of an ancient pagoda with installed SMA damper
    Huang, Xiang-Yun
    Wang, Feng-Hua
    Zhendong yu Chongji/Journal of Vibration and Shock, 2012, 31 (20): : 38 - 45
  • [10] Seismic Performance Analysis and Design Method for the SMA-Friction Damper in Cable Dome Structure
    Lu Y.
    Luo Q.
    Wang M.
    Wang Y.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2023, 56 (10): : 1078 - 1089