A combined non-contact acoustic thermometer and infrared hygrometer for atmospheric measurements

被引:8
|
作者
Underwood, R. [1 ]
Gardiner, T. [1 ]
Finlayson, A. [1 ]
Few, J. [1 ]
Wilkinson, J. [1 ]
Bell, S. [1 ]
Merrison, J. [2 ]
Iverson, J. J. [2 ]
de Podesta, M. [1 ]
机构
[1] Natl Phys Lab, Hampton Rd, Teddington TW11 0LW, Middx, England
[2] Aarhus Univ, Dept Phys & Astron, DK-8000 Aarhus C, Denmark
关键词
atmospheric temperature; atmospheric humidity; non-contact measurement; acoustic temperature; TDLAS;
D O I
10.1002/met.1513
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Temperature and humidity measurements in the upper atmosphere are of critical importance for understanding the Earth's climate. However, such measurements are difficult for several reasons. Rising sondes carry moisture upwards, compromising measurements in the dry stratospheric environment. In addition, the difference in the time constants of thermometers and hygrometers leads to difficulties in determining the extent of saturation of the air. Finally, the effects of insolation, evaporative cooling and the poor thermal contact with the air compound the other measurement problems. To address these issues, tests on a new non-contact temperature and humidity sensor (non-contact thermometer and hygrometer, NCTAH), which can make rapid non-contact measurements in atmospheric air, have been reported. The temperature and humidity measurements are made using an acoustic interferometer and a tuneable diode laser absorption spectrometer (TDLAS), respectively. This combination of sensors offers many potential advantages and allows each sensor to supply a key correction required by the other. The present study describes the design rationale and reports test results measured at the National Physical Laboratory and results from simulated ascents through the atmosphere (to -57 degrees C and 130 hPa characteristic of an altitude of 15 km) at the Planetary Environment Facility at the University of Aarhus, Denmark. The NCTAH makes two temperature measurements per second with a resolution of approximate to 0.01 degrees C and a likely uncertainty of measurement of u(k = 1) = 0.1 degrees C. Water vapour mixing ratios were measured over a range of approximate to 100 to 3 x 10(4) ppmv corresponding to dew points from -42 to +24 degrees C at atmospheric pressure.
引用
收藏
页码:830 / 835
页数:6
相关论文
共 50 条
  • [41] Non-contact multiband emissivity measurements
    Mazikowski, A
    [J]. OPTOELECTRONIC AND ELECTRONIC SENSORS V, 2002, : 240 - 243
  • [42] Non-contact photovoltage measurements in SiC
    Koshka, Y
    Mazzola, MS
    [J]. SILICON CARBIDE AND RELATED MATERIALS - 1999 PTS, 1 & 2, 2000, 338-3 : 699 - 702
  • [43] PREDICTION OF CARDLAC INDEX (CI) BY BODY SURFACE TEMPERATURES MEASURED WITH TEMPERATURE PROBES AND NON-CONTACT INFRARED THERMOMETER
    Huber, W.
    Meidert, A.
    Saugel, B.
    Phillip, V.
    Schultheiss, C.
    Mair, S.
    Mayr, U.
    Schmid, R.
    [J]. INTENSIVE CARE MEDICINE, 2012, 38 : S79 - S79
  • [44] Impact of measuring distance and exposure to cold outdoor environment on the temperature measurement using a non-contact infrared thermometer
    Peng, Rui
    Huang, Yuanshen
    Zhu, Xuejun
    Li, Xueying
    Li, Hang
    [J]. CHINESE MEDICAL JOURNAL, 2022, 135 (01) : 121 - 122
  • [45] Comparison of non-contact infrared forehead thermometer to standard temperature measurement in neonatal intensive care unit patients
    Can, Emrah
    Bulbul, Ali
    Uslu, Sinan
    Nuhoglu, Asiye
    [J]. TURK PEDIATRI ARSIVI-TURKISH ARCHIVES OF PEDIATRICS, 2010, 45 (03): : 257 - 263
  • [46] Impact of measuring distance and exposure to cold outdoor environment on the temperature measurement using a non-contact infrared thermometer
    Peng Rui
    Huang Yuanshen
    Zhu Xuejun
    Li Xueying
    Li Hang
    [J]. 中华医学杂志(英文版), 2022, 135 (01) : 121 - 122
  • [47] Non-Contact Infrared Thermometry in Febrile Infants
    Thiagarajan, Srinivasan
    Balaji, Rajeshwar
    Pothapregada, Sriram
    [J]. INDIAN PEDIATRICS, 2020, 57 (09) : 857 - 858
  • [48] Clinical evaluation of non-contact infrared thermometers
    Sullivan, Stacey J. L.
    Rinaldi, Jean E.
    Hariharan, Prasanna
    Casamento, Jon P.
    Baek, Seungchul
    Seay, Nathanael
    Vesnovsky, Oleg
    Topoleski, L. D. Timmie
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [49] Non-Contact Infrared Thermometry in Febrile Infants
    Srinivasan Thiagarajan
    Rajeshwar Balaji
    Sriram Pothapregada
    [J]. Indian Pediatrics, 2020, 57 (9) : 857 - 858
  • [50] Influence of sun radiation on results of non-contact temperature measurements in far infrared range
    Madura, H
    Kolodziejczyk, M
    [J]. OPTO-ELECTRONICS REVIEW, 2005, 13 (03) : 253 - 257