Sources of Error in Toric Intraocular Lens Power Calculation

被引:32
|
作者
Hirnschall, Nino [1 ]
Findl, Oliver [1 ,3 ]
Bayer, Natascha [1 ]
Leisser, Christoph [1 ]
Norrby, Sverker
Zimper, Eva [1 ]
Hoffmann, Peter [2 ]
机构
[1] Hanusch Hosp, Vienna Inst Res Ocular Surg, A Karl Landsteiner Inst, Vienna, Austria
[2] Eye & Laser Clin, Castrop Rauxel, Germany
[3] Moorfields Eye Hosp NHS Fdn Trust, London, England
关键词
OPTICAL COHERENCE TOMOGRAPHY; RESIDUAL REFRACTIVE ASTIGMATISM; POSTERIOR CORNEAL SURFACE; CATARACT-SURGERY; VECTOR ANALYSIS; BIOMETER REPEATABILITY; ROTATIONAL STABILITY; CLINICAL-OUTCOMES; TEAR FILM; IMPLANTATION;
D O I
10.3928/1081597X-20200729-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the influencing factors on remaining astigmatism after implanting a toric intraocular tens (IOL) during cataract surgery. METHODS: This retrospective study included parameters that were considered to have an influence on toric IOL power calculation. Therefore, data from the literature and the authors' own data were used. This included axial eye length, anterior chamber depth, central corneal thickness, corneal radii (anterior and posterior), diurnal changes of the cornea, interdevice differences, rotational misalignment of the IOL, tilt and decentration of the IOL, pupil size, angle kappa, and surgically induced astigmatism. Ray-tracing and Gaussian error propagation analysis was performed to quantify the sources of error. RESULTS: In total, 4,949 eyes (4,365 eyes of 42 studies and 584 eyes of retrospectively analyzed study data) were included in the study and the difference vector between aimed and calculated remaining astigmatism was 0.81 diopters (D). The main source of error was the preoperative measurement of the cornea (27%), followed by IOL misalignment (14.4%) and IOL tilt (11.3%). Other factors, such as angle kappa (10.9%), pupil size (8.1%), surgically induced astigmatism (7.8%), anterior chamber depth (7.5%), axial eye length (7.5%), and decentration (5.6%), also contributed to the refractive astigmatic error. CONCLUSIONS: The main source of error in toric IOL power calculation is the preoperative corneal measurement followed by IOL misalignment and tilt.
引用
收藏
页码:646 / 652
页数:7
相关论文
共 50 条
  • [31] Biometry and intraocular lens power calculation
    Lee, Alexander C.
    Qazi, Mujtaba A.
    Pepose, Jay S.
    CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (01) : 13 - 17
  • [32] Calculation of intraocular lens power: a review
    Olsen, Thomas
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (05): : 472 - 485
  • [33] Axis Misalignment of Toric Intraocular Lens: Placement Error and Postoperative Rotation
    Inoue, Yasushi
    Takehara, Hiroyasu
    Oshika, Tetsuro
    OPHTHALMOLOGY, 2017, 124 (09) : 1424 - 1425
  • [34] Optimized keratometry and total corneal astigmatism for toric intraocular lens calculation
    Savini, Giacomo
    Naeser, Kristian
    Schiano-Lomoriello, Domenico
    Ducoli, Pietro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (09): : 1140 - 1148
  • [35] Impact of Posterior Corneal Surface on Toric Intraocular Lens (IOL) Calculation
    Preussner, Paul-Rolf
    Hoffmann, Peter
    Wahl, Jochen
    CURRENT EYE RESEARCH, 2015, 40 (08) : 809 - 814
  • [36] Toric Intraocular Lens in Keratoconus
    Ramirez-Miranda, Arturo
    Jaimes, Martha
    Graue-Hernandez, Enrique O.
    Ramirez-Luquin, Tito
    Navas, Alejandro
    CORNEA, 2012, 31 (03) : 335 - 336
  • [37] Toric Intraocular Lens Calculations
    Savini, Giacomo
    Hoffer, Kenneth J.
    ARCHIVES OF OPHTHALMOLOGY, 2012, 130 (07) : 947 - 948
  • [38] Determining the power of a thin toric intraocular lens in an astigmatic eye
    Mackenzie, GE
    Harris, WF
    OPTOMETRY AND VISION SCIENCE, 2002, 79 (10) : 667 - 671
  • [39] Toric intraocular lens report
    Grabow, HB
    ANNALS OF OPHTHALMOLOGY-GLAUCOMA, 1997, 29 (03): : 161 - 163
  • [40] Refractive error with optimum intraocular lens power calculation after glaucoma filtering surgery
    Tan, HY
    Wu, SC
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (12): : 2595 - 2597