Comparison of MRI-based and CT/MRI fusion-based postimplant dosimetric analysis of prostate brachytherapy

被引:47
|
作者
Tanaka, Osamu
Hayashi, Shinya
Matsuo, Masayuki
Sakurai, Kota
Nakano, Masahiro
Maeda, Sunaho
Kajita, Kimihiro
Deguchi, Takashi
Hoshi, Hiroaki
机构
[1] Gifu Univ, Sch Med, Dept Radiol, Gifu 5011194, Japan
[2] Gifu Univ, Sch Med, Dept Urol, Gifu 500, Japan
关键词
prostate cancer; brachytherapy; CT/MRI fusion; postimplant dosimetry;
D O I
10.1016/j.ijrobp.2006.06.023
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The aim of this study was to compare the outcomes between magnetic resonance imaging (MRI)-based and computed tomography (CT)/MRI fusion-based postimplant dosimetry methods in permanent prostate brachytherapy. Methods and Materials: Between October 2004 and March 2006, a total of 52 consecutive patients with prostate cancer were treated by brachytherapy, and postimplant dosimetry was performed using CT/MRI fusion. The accuracy and reproducibility were prospectively compared between MRI-based dosimetry and CT/MRI fusion-based dosimetry based on the dose-volume histogram (DVH) related parameters as recommended by the American Brachytherapy Society. Results: The prostate volume was 15.97 +/- 6.17 cc (mean +/- SD) in MRI-based dosimetry, and 15.97 +/- 6.02 cc in CT/MRI fusion-based dosimetry without statistical difference. The prostate V100 was 94.5% and 93.0% in MRI-based and CT/MRI fusion-based dosimetry, respectively, and the difference was statistically significant (p = 0.002). The prostate D90 was 119.4% and 114.4% in MRI-based and CT/MRI fusion-based dosimetry, respectively, and the difference was statistically significant (p = 0.004). Conclusion: Our current results suggested that, as with fusion images, MR images allowed accurate contouring of the organs, but they tended to overestimate the analysis of postimplant dosimetry in comparison to CT/MRI fusion images. Although this MRI-based dosimetric discrepancy was negligible, MRI-based dosimetry was acceptable and reproducible in comparison to CT-based dosimetry, because the difference between MRI-based and CT/MRI fusion-based results was smaller than that between CT-based and CT/MRI fusion-based results as previously reported. (c) 2006 Elsevier Inc.
引用
收藏
页码:597 / 602
页数:6
相关论文
共 50 条
  • [41] MRI-based virtual pathology of the prostate
    Chatterjee, Aritrick
    Dwivedi, Durgesh Kumar
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2024, 37 (04): : 709 - 720
  • [42] Improved tumour control probability with MRI-based prostate brachytherapy treatment planning
    Dinkla, Anna M.
    Pieters, Bradley R.
    Koedooder, Kees
    van Wieringen, Niek
    van der Laarse, Rob
    van der Grient, Johan N.
    Rasch, Coen R.
    Koning, Caro C.
    Bel, Arjan
    ACTA ONCOLOGICA, 2013, 52 (03) : 658 - 665
  • [43] MRI-based synthetic CT in the detection of knee osteoarthritis: Comparison with CT
    Arbabi, Saeed
    Foppen, Wouter
    Gielis, Willem Paul
    van Stralen, Marijn
    Jansen, Mylene
    Arbabi, Vahid
    de Jong, Pim A.
    Weinans, Harrie
    Seevinck, Peter
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2023, 41 (11) : 2530 - 2539
  • [44] Beyond the AJR: MRI-Based CT Analysis of Spondyloarthropathy
    Potter, Hollis G.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2025, 224 (01)
  • [45] MRI-guided prostate radiation therapy planning: Investigation of dosimetric accuracy of MRI-based dose planning
    Lambert, Jonathan
    Greer, Peter B.
    Menk, Fred
    Patterson, Jackie
    Parker, Joel
    Dahl, Kara
    Gupta, Sanjiv
    Capp, Anne
    Wratten, Chris
    Tang, Colin
    Kumar, Mahesh
    Dowling, Jason
    Hauville, Sarah
    Hughes, Cynthia
    Fisher, Kristen
    Lau, Peter
    Denham, James W.
    Salvado, Olivier
    RADIOTHERAPY AND ONCOLOGY, 2011, 98 (03) : 330 - 334
  • [46] MRI-based Preplanning Using CT And MRI Data Fusion In Patients With Cervical Cancer Treated With 3D-based Brachytherapy: Feasibility And Accuracy Study
    Dolezel, M.
    Vanasek, J.
    Odrazka, K.
    Zizka, J.
    Spitzer, D.
    Kroulik, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S461 - S461
  • [47] CT/MRI-based system for 3-D Brachytherapy treatment planning
    Xiang, H
    Zhuang, TG
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1196 - 1197
  • [48] MRI-based Preplanning Using CT and MRI Data Fusion in Patients With Cervical Cancer Treated With 3D-based Brachytherapy: Feasibility and Accuracy Study
    Dolezel, Martin
    Odrazka, Karel
    Zizka, Jan
    Vanasek, Jaroslav
    Kohlova, Tereza
    Kroulik, Tomas
    Spitzer, Dusan
    Ryska, Pavel
    Tichy, Michal
    Kostal, Milan
    Jalcova, Lubica
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (01): : 146 - 152
  • [49] Effect of pulse sequence parameter selection on signal strength in positive-contrast MRI markers for MRI-based prostate postimplant assessment
    Lim, Tze Yee
    Kudchadker, Rajat J.
    Wang, Jihong
    Stafford, R. Jason
    MacLellan, Christopher
    Rao, Arvind
    Ibbott, Geoffrey S.
    Frank, Steven J.
    MEDICAL PHYSICS, 2016, 43 (07) : 4312 - 4322
  • [50] MRI-Based Prostate SBRT Treatment Planning Using Synthetic CT
    Scholey, J.
    Nano, T.
    Miao, X.
    Larson, P.
    Descovich, M.
    MEDICAL PHYSICS, 2021, 48 (06)