Comparison of MRI-based and CT/MRI fusion-based postimplant dosimetric analysis of prostate brachytherapy

被引:47
|
作者
Tanaka, Osamu
Hayashi, Shinya
Matsuo, Masayuki
Sakurai, Kota
Nakano, Masahiro
Maeda, Sunaho
Kajita, Kimihiro
Deguchi, Takashi
Hoshi, Hiroaki
机构
[1] Gifu Univ, Sch Med, Dept Radiol, Gifu 5011194, Japan
[2] Gifu Univ, Sch Med, Dept Urol, Gifu 500, Japan
关键词
prostate cancer; brachytherapy; CT/MRI fusion; postimplant dosimetry;
D O I
10.1016/j.ijrobp.2006.06.023
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The aim of this study was to compare the outcomes between magnetic resonance imaging (MRI)-based and computed tomography (CT)/MRI fusion-based postimplant dosimetry methods in permanent prostate brachytherapy. Methods and Materials: Between October 2004 and March 2006, a total of 52 consecutive patients with prostate cancer were treated by brachytherapy, and postimplant dosimetry was performed using CT/MRI fusion. The accuracy and reproducibility were prospectively compared between MRI-based dosimetry and CT/MRI fusion-based dosimetry based on the dose-volume histogram (DVH) related parameters as recommended by the American Brachytherapy Society. Results: The prostate volume was 15.97 +/- 6.17 cc (mean +/- SD) in MRI-based dosimetry, and 15.97 +/- 6.02 cc in CT/MRI fusion-based dosimetry without statistical difference. The prostate V100 was 94.5% and 93.0% in MRI-based and CT/MRI fusion-based dosimetry, respectively, and the difference was statistically significant (p = 0.002). The prostate D90 was 119.4% and 114.4% in MRI-based and CT/MRI fusion-based dosimetry, respectively, and the difference was statistically significant (p = 0.004). Conclusion: Our current results suggested that, as with fusion images, MR images allowed accurate contouring of the organs, but they tended to overestimate the analysis of postimplant dosimetry in comparison to CT/MRI fusion images. Although this MRI-based dosimetric discrepancy was negligible, MRI-based dosimetry was acceptable and reproducible in comparison to CT-based dosimetry, because the difference between MRI-based and CT/MRI fusion-based results was smaller than that between CT-based and CT/MRI fusion-based results as previously reported. (c) 2006 Elsevier Inc.
引用
收藏
页码:597 / 602
页数:6
相关论文
共 50 条
  • [31] MRI-based preplanning in low-dose-rate prostate brachytherapy
    Tanaka, O.
    Hayashi, S.
    Matsuo, M.
    Nakano, M.
    Kubota, Y.
    Ohtakara, K.
    Okada, S.
    Deguchi, T.
    Hoshi, H.
    Wenz, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S655 - S655
  • [32] MRI-Based Virtual Volume Study for Permanent Prostate Brachytherapy (PPB)
    Le, Y.
    Ng, S.
    Yue, Y.
    Guo, G.
    Holmes, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [33] CT-versus MRI-based contouring in cervical cancer brachytherapy
    Viswanathan, A.
    Dimopoulos
    Kirisits, C.
    Berger, D.
    Poetter, R.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S80 - S80
  • [34] Comparison of CT and MRI-Based Clinical Target Volume Contours at the Time of Brachytherapy for Cervical Cancer
    Swanick, C. W.
    Castle, K. O.
    Vedam, S.
    Turner, L. M.
    Yang, J.
    Rauch, G. M.
    Jhingran, A.
    Eifel, P. J.
    Klopp, A. H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E282 - E282
  • [35] Parallel imaging compressed sensing for accelerated imaging and improved signal-to-noise ratio in MRI-based postimplant dosimetry of prostate brachytherapy
    Sanders, Jeremiah W.
    Song, Hao
    Frank, Steven J.
    Bathala, Tharakeswara
    Venkatesan, Aradhana M.
    Anscher, Mitchell
    Tang, Chad
    Bruno, Teresa L.
    Wei, Wei
    Ma, Jingfei
    BRACHYTHERAPY, 2018, 17 (05) : 816 - 824
  • [36] MRI-Based Synthetic CT for Radiation Treatment of Prostate Cancer
    Yang, X.
    Lei, Y.
    Wang, T.
    Patel, P. R.
    Jiang, X.
    Liu, T.
    Dhabaan, A. H.
    Shim, H.
    Mao, H.
    Curran, W. J., Jr.
    Jani, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : S193 - S194
  • [37] URO - PET/CT as a supplement to MRI-based prostate diagnostics
    Graewert, Stephanie
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2024, 196 (11): : 1109 - 1110
  • [38] Urethral dosimetric implications of a multifocal MRI-based microboost in prostate robotic SBRT
    Lischalk, Jonathan W.
    Santos, Vianca F.
    Akerman, Meredith
    Mendez, Christopher
    Sanchez, Astrid
    Wysock, James S.
    Huang, William C.
    Tam, Moses M.
    Corcoran, Anthony
    Carpenter, Todd J.
    Witten, Matthew R.
    Evans, Andrew J.
    Katz, Aaron
    Mahadevan, Anand
    Zelefsky, Michael J.
    Haas, Jonathan A.
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3719 - S3720
  • [39] The American Brachytherapy Society recommendations for permanent prostate brachytherapy postimplant dosimetric analysis
    Nag, S
    Bice, W
    DeWyngaery, K
    Prestidge, B
    Stock, R
    Yu, Y
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (01): : 221 - 230
  • [40] Dosimetric Evaluation of MRI-Based Synthetic CT for Stereotactic Radiosurgery of Brain Cancer
    Wang, T.
    Manohar, N.
    Lei, Y.
    Shu, H.
    Tian, S.
    Higgins, K.
    Dhabaan, A.
    Dong, X.
    Liu, T.
    Curran, W.
    Yang, X.
    MEDICAL PHYSICS, 2018, 45 (06) : E701 - E701