Comparison of MRI-based and CT/MRI fusion-based postimplant dosimetric analysis of prostate brachytherapy

被引:47
|
作者
Tanaka, Osamu
Hayashi, Shinya
Matsuo, Masayuki
Sakurai, Kota
Nakano, Masahiro
Maeda, Sunaho
Kajita, Kimihiro
Deguchi, Takashi
Hoshi, Hiroaki
机构
[1] Gifu Univ, Sch Med, Dept Radiol, Gifu 5011194, Japan
[2] Gifu Univ, Sch Med, Dept Urol, Gifu 500, Japan
关键词
prostate cancer; brachytherapy; CT/MRI fusion; postimplant dosimetry;
D O I
10.1016/j.ijrobp.2006.06.023
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The aim of this study was to compare the outcomes between magnetic resonance imaging (MRI)-based and computed tomography (CT)/MRI fusion-based postimplant dosimetry methods in permanent prostate brachytherapy. Methods and Materials: Between October 2004 and March 2006, a total of 52 consecutive patients with prostate cancer were treated by brachytherapy, and postimplant dosimetry was performed using CT/MRI fusion. The accuracy and reproducibility were prospectively compared between MRI-based dosimetry and CT/MRI fusion-based dosimetry based on the dose-volume histogram (DVH) related parameters as recommended by the American Brachytherapy Society. Results: The prostate volume was 15.97 +/- 6.17 cc (mean +/- SD) in MRI-based dosimetry, and 15.97 +/- 6.02 cc in CT/MRI fusion-based dosimetry without statistical difference. The prostate V100 was 94.5% and 93.0% in MRI-based and CT/MRI fusion-based dosimetry, respectively, and the difference was statistically significant (p = 0.002). The prostate D90 was 119.4% and 114.4% in MRI-based and CT/MRI fusion-based dosimetry, respectively, and the difference was statistically significant (p = 0.004). Conclusion: Our current results suggested that, as with fusion images, MR images allowed accurate contouring of the organs, but they tended to overestimate the analysis of postimplant dosimetry in comparison to CT/MRI fusion images. Although this MRI-based dosimetric discrepancy was negligible, MRI-based dosimetry was acceptable and reproducible in comparison to CT-based dosimetry, because the difference between MRI-based and CT/MRI fusion-based results was smaller than that between CT-based and CT/MRI fusion-based results as previously reported. (c) 2006 Elsevier Inc.
引用
收藏
页码:597 / 602
页数:6
相关论文
共 50 条
  • [1] Postimplant Dosimetry of Permanent Prostate Brachytherapy: Comparison of MRI-Only and CT-MRI Fusion-Based Workflows
    Nosrati, Reyhaneh
    Wronski, Matthew
    Tseng, Chia-Lin
    Chung, Hans
    Pejovic-Milic, Ana
    Morton, Gerard
    Stanisz, Greg J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 106 (01): : 206 - 215
  • [2] MRI-based postimplant dosimetric assessment
    Chang, Z.
    Wang, Z.
    Lee, W.
    Yin, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S662 - S662
  • [3] CT AND MRI FUSION FOR POSTIMPLANT PROSTATE BRACHYTHERAPY EVALUATION
    Dehghan, Ehsan
    Le, Yi
    Lee, Junghoon
    Song, Daniel Y.
    Fichtinger, Gabor
    Prince, Jerry L.
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 625 - 628
  • [4] CT- and MRI-based seed localization in postimplant evaluation after prostate brachytherapy
    De Brabandere, Marisol
    Al-Qaisieh, Bashar
    De Wever, Liesbeth
    Haustermans, Karin
    Kirisits, Christian
    Moerland, Marinus A.
    Oyen, Raymond
    Rijnders, Alex
    Van den Heuvel, Frank
    Siebert, Frank-Andre
    BRACHYTHERAPY, 2013, 12 (06) : 580 - 588
  • [5] Importance of the CT/MRI fusion method as a learning tool for CT-based postimplant dosimetry in prostate brachytherapy
    Tanaka, Osamu
    Hayashi, Shinya
    Sakurai, Kota
    Matsuo, Masayuki
    Nakano, Masahiro
    Maeda, Sunaho
    Hoshi, Hiroaki
    Deguchi, Takashi
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 (03) : 303 - 308
  • [6] Effect of edema on postimplant dosimetry in prostate brachytherapy using CT/MRI fusion
    Tanaka, O.
    Hayashi, S.
    Matsuo, M.
    Nakano, M.
    Uno, H.
    Ohtakara, K.
    Okada, S.
    Hoshi, H.
    Deguchi, T.
    EJC SUPPLEMENTS, 2007, 5 (04): : 292 - 292
  • [7] Effect of edema on postimplant dosimetry in prostate brachytherapy using CT/MRI fusion
    Tanaka, Osamu
    Hayashi, Shinya
    Matsuo, Masayuki
    Nakano, Masahiro
    Uno, Hiromi
    Ohtakara, Kazuhiro
    Miyoshi, Toshiharu
    Deguchi, Takashi
    Hoshi, Hiroaki
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (02): : 614 - 618
  • [8] Effect of edema on postimplant dosimetry in prostate brachytherapy using CT/MRI fusion
    Ohtakara, K.
    Tanaka, O.
    Hayashi, S.
    Matsuo, M.
    Nakano, M.
    Uno, H.
    Okada, S.
    Deguchi, T.
    Hoshi, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S730 - S730
  • [9] MRI-BASED PROSTATE BRACHYTHERAPY SEED LOCALIZATION
    Kuo, Nathanael
    Lee, Junghoon
    Tempany, Clare
    Stuber, Matthias
    Prince, Jerry
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 1397 - 1400
  • [10] MRI-based Treatment Planning for Prostate Brachytherapy
    Albert, J. M.
    Zhang, M.
    Bruno, T. L.
    Kudchadker, R. J.
    Swanson, D. A.
    Frank, S. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S372 - S373