Integrated optimization of the building envelope and the HVAC system in nZEB refurbishment

被引:27
|
作者
Delac, Boris [1 ]
Pavkovic, Branimir [1 ]
Lenic, Kristian [1 ]
Maderic, Damir [2 ]
机构
[1] Univ Rijeka, Fac Engn, Dept Thermodynam & Energy Engn, Vukovarska 58, Rijeka, Croatia
[2] Univ North, Mech Engn Dept, 104 Brigade 3, Varazhdin 42000, Croatia
关键词
HVAC; Optimization; Nearly zero energy building; Cost optimal; MULTIOBJECTIVE OPTIMIZATION; ENERGY-CONSUMPTION; COST-OPTIMALITY; DESIGN; RETROFIT; ACHIEVE; HOTEL;
D O I
10.1016/j.applthermaleng.2022.118442
中图分类号
O414.1 [热力学];
学科分类号
摘要
The research presents the method for optimization of a building with its heating, ventilation and air-conditioning (HVAC) system in the scope of achieving nearly zero energy building (nZEB) in the context of Energy Performance of Buildings Directive 2010/31/EU. The method is based on coupling the dynamic simulation models created in Trnsys software with the non-dominated sorting genetic algorithm (NSGA-II), as the engine which performs an optimization process to minimize global cost (GC) and primary energy consumption (PEC). The optimization comprises energy efficiency measures (EEM) on a building envelope with a parametrized model of the HVAC system. The procedure implements building simulations under design weather conditions for heating and cooling to establish the connection between building design and the HVAC system size. The analysis is performed using discrete equipment sizes and specifications according to manufacturers' data, ensuring the selection of actual products with their sizes and costs. In continuation annual simulations using referent year data were performed. Several HVAC systems were considered, ranging from conventional natural gas-based systems to systems based on renewable energy sources (RES). The method is applied in the case study of the refurbishment of a representative hotel building on the Croatian Adriatic. The results reveal a large gap in terms of PEC between the nZEB system (biomass boiler, solar thermal collectors and absorption chiller, 138.9 kWh/m(2)) and the cost-optimal system (natural gas boiler and compression chiller, 269.6 kWh/m(2)). The most promising solution for a hotel with year-round operation character is water-to-water heat pump system using seawater as the heat source and sink (170.2 kWh/m(2)). When the use of seawater is not possible, or when cooling energy prevails over heating energy use, air-to-water heat pump system appears to be suitable solution (176.4 kWh/m(2)). It is found that in addition to HVAC system with low PEC, the application of solar photovoltaic (PV) system is required to reach Croatian nZEB target for a renewed hotel (115 kWh/m(2)). Further analysis of the results shows that the optimal parameters of EEM vary depending on applied HVAC system. The results indicate that optimal solutions are achieved when the HVAC system size matches the design load. Therefore, excessive oversizing of the HVAC system may have negative impact on GC. Based on the results and the findings, conclusions and general guidelines for the refurbishment of a hotel building on the Adriatic coast are established.
引用
收藏
页数:23
相关论文
共 50 条
  • [41] Energy-Constrained Indoor Air Quality Optimization for HVAC System in Smart Building
    Li, Yi
    Ma, Nan
    Guo, Lin
    IEEE SYSTEMS JOURNAL, 2023, 17 (01): : 361 - 370
  • [42] Cyber-Enabled Optimization of HVAC System Control in Open Space of Office Building
    Peng, Bo
    Hsieh, Sheng-Jen
    SENSORS, 2023, 23 (10)
  • [43] The Framework of an Optimization Model for Building Envelope
    Lapinskiene, Vilune
    Martinaitis, Vytautas
    MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, 2013, 57 : 670 - 677
  • [44] Building HVAC control systems - Role of controls and optimization
    Sane, H. S.
    Haugstetter, C.
    Bortoff, S. A.
    2006 AMERICAN CONTROL CONFERENCE, VOLS 1-12, 2006, 1-12 : 1121 - +
  • [45] INNOVATIVE FACADE REFURBISHMENT WITH INTEGRATED AIR DUCTING FOR THE EXISTING BUILDING STOCK
    Ziegler, Matthias
    Krause, Michael
    SUSTAINABLE BUILDING AND REFURBISHMENT FOR NEXT GENERATIONS, 2013, : 207 - 210
  • [46] Optimal exergy control of building HVAC system
    Razmara, M.
    Maasoumy, M.
    Shahbakhti, M.
    Robinett, R. D., III
    APPLIED ENERGY, 2015, 156 : 555 - 565
  • [47] Wind loading on trees integrated with a building envelope
    Aly, Aly Mousaad
    Fossati, Fabio
    Muggiasca, Sara
    Argentini, Tommaso
    Bitsuamlak, Girma
    Franchi, Alberto
    Longarini, Nicola
    Crespi, Pietro
    Chowdhury, Arindam Gan
    WIND AND STRUCTURES, 2013, 17 (01) : 69 - 85
  • [48] Historic building gets new HVAC system
    HPAC Heat Piping Air Cond, 5 (87-88):
  • [49] TOWARDS AN INTEGRAL APPROACH OF BUILDING AND HVAC SYSTEM
    HENSEN, JLM
    ENERGY AND BUILDINGS, 1993, 19 (04) : 297 - 302
  • [50] Redesigning the HVAC System of a University Laboratory Building
    Madineedi, Navya T.
    Harrell, Justin M.
    Mathias, James A.
    ASHRAE TRANSACTIONS 2017, VOL 123, PT 2, 2017, 123 : 217 - 228