Integrated optimization of the building envelope and the HVAC system in nZEB refurbishment

被引:27
|
作者
Delac, Boris [1 ]
Pavkovic, Branimir [1 ]
Lenic, Kristian [1 ]
Maderic, Damir [2 ]
机构
[1] Univ Rijeka, Fac Engn, Dept Thermodynam & Energy Engn, Vukovarska 58, Rijeka, Croatia
[2] Univ North, Mech Engn Dept, 104 Brigade 3, Varazhdin 42000, Croatia
关键词
HVAC; Optimization; Nearly zero energy building; Cost optimal; MULTIOBJECTIVE OPTIMIZATION; ENERGY-CONSUMPTION; COST-OPTIMALITY; DESIGN; RETROFIT; ACHIEVE; HOTEL;
D O I
10.1016/j.applthermaleng.2022.118442
中图分类号
O414.1 [热力学];
学科分类号
摘要
The research presents the method for optimization of a building with its heating, ventilation and air-conditioning (HVAC) system in the scope of achieving nearly zero energy building (nZEB) in the context of Energy Performance of Buildings Directive 2010/31/EU. The method is based on coupling the dynamic simulation models created in Trnsys software with the non-dominated sorting genetic algorithm (NSGA-II), as the engine which performs an optimization process to minimize global cost (GC) and primary energy consumption (PEC). The optimization comprises energy efficiency measures (EEM) on a building envelope with a parametrized model of the HVAC system. The procedure implements building simulations under design weather conditions for heating and cooling to establish the connection between building design and the HVAC system size. The analysis is performed using discrete equipment sizes and specifications according to manufacturers' data, ensuring the selection of actual products with their sizes and costs. In continuation annual simulations using referent year data were performed. Several HVAC systems were considered, ranging from conventional natural gas-based systems to systems based on renewable energy sources (RES). The method is applied in the case study of the refurbishment of a representative hotel building on the Croatian Adriatic. The results reveal a large gap in terms of PEC between the nZEB system (biomass boiler, solar thermal collectors and absorption chiller, 138.9 kWh/m(2)) and the cost-optimal system (natural gas boiler and compression chiller, 269.6 kWh/m(2)). The most promising solution for a hotel with year-round operation character is water-to-water heat pump system using seawater as the heat source and sink (170.2 kWh/m(2)). When the use of seawater is not possible, or when cooling energy prevails over heating energy use, air-to-water heat pump system appears to be suitable solution (176.4 kWh/m(2)). It is found that in addition to HVAC system with low PEC, the application of solar photovoltaic (PV) system is required to reach Croatian nZEB target for a renewed hotel (115 kWh/m(2)). Further analysis of the results shows that the optimal parameters of EEM vary depending on applied HVAC system. The results indicate that optimal solutions are achieved when the HVAC system size matches the design load. Therefore, excessive oversizing of the HVAC system may have negative impact on GC. Based on the results and the findings, conclusions and general guidelines for the refurbishment of a hotel building on the Adriatic coast are established.
引用
收藏
页数:23
相关论文
共 50 条
  • [31] Two-layer energy optimization of HVAC system in a cement factory building
    Lu, Xiaoquan
    Fang, Kaijie
    Zhou, Yuqi
    Sheng, Ju
    Chen, Hanmiao
    Sustainable Energy Research, 2024, 11 (01)
  • [32] Machine learning driven building integrated photovoltaic (BIPV) envelope design optimization
    Imalka, Samarasinghalage Tharushi
    Yang, Rebecca Jing
    Zhao, Yusen
    ENERGY AND BUILDINGS, 2024, 324
  • [33] Real-time building heat gains prediction and optimization of HVAC setpoint: An integrated framework
    Wang, Zu
    Calautit, John
    Wei, Shuangyu
    TIen, Paige Wenbin
    Xia, Liang
    JOURNAL OF BUILDING ENGINEERING, 2022, 49
  • [34] The effect of building envelope on peak cooling load reduction of HVAC system and its impact on energy conservation
    Li, Zhun
    Yang, Changzhi
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 145 - 151
  • [35] Model implementation and verification of the envelope, HVAC and controller of an office building in Modelica
    Jorissen, F.
    Boydens, W.
    Helsen, L.
    JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2019, 12 (04) : 445 - 464
  • [36] Building-to-grid optimal control of integrated MicroCSP and building HVAC system for optimal demand response services
    Toub, Mohamed
    Robinett, Rush D., III
    Shahbakhti, Mahdi
    OPTIMAL CONTROL APPLICATIONS & METHODS, 2023, 44 (02): : 866 - 884
  • [37] MasterFormat™ 2004 -: HVAC specifications for integrated building design
    Gulledge, CE
    King, MJ
    Knight, D
    ASHRAE JOURNAL, 2006, 48 (05) : 80 - 86
  • [38] NATURWALL© - A solar timber facade system for building refurbishment: optimization process through in field measurements
    Callegari, Guido
    Spinelli, Antonio
    Bianco, Lorenza
    Serra, Valentina
    Fantucci, Stefano
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 291 - 296
  • [39] Optimization of Building Envelope and Heating System in Heating Areas in Northern China
    Jie Pengfei
    Li Deying
    Zhu Neng
    ADVANCES IN CIVIL ENGINEERING, PTS 1-6, 2011, 255-260 : 1344 - +
  • [40] Decision Support System for technology selection based on multi-criteria ranking: Application to NZEB refurbishment
    Salvado, Laura Laguna
    Villeneuve, Eric
    Masson, Dimitri
    Akle, Audrey Abi
    Bur, Nicolas
    BUILDING AND ENVIRONMENT, 2022, 212