Comparison of Hemodynamics After Aortic Root Replacement Using Valve-Sparing or Bioprosthetic Valved Conduit

被引:34
|
作者
Collins, Jeremy D.
Semaan, Edouard
Barker, Alex
McCarthy, Patrick M.
Carr, James C.
Markl, Michael
Malaisrie, S. Chris
机构
[1] Northwestern Univ, Dept Radiol, Feinberg Sch Med, Chicago, IL 60611 USA
[2] Northwestern Univ, Div Cardiac Surg, Feinberg Sch Med, Chicago, IL 60611 USA
[3] Northwestern Univ, McCormick Sch Engn, Dept Biomed Engn, Chicago, IL 60611 USA
来源
ANNALS OF THORACIC SURGERY | 2015年 / 100卷 / 05期
关键词
PHASE-CONTRAST MRI; MAGNETIC-RESONANCE; FLOW PATTERNS; ASCENDING AORTA; MARFAN-SYNDROME; BLOOD-FLOW; SURGERY; GRAFT; ANEURYSM; ENERGY;
D O I
10.1016/j.athoracsur.2015.04.109
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The purpose of this study is to compare aortic hemodynamics and blood flow patterns using in-vivo four-dimensional (4D) flow magnetic resonance imaging (MRI) in patients after valve-sparing aortic root replacement (VSARR) and aortic root replacement with bioprosthetic valves (BIO-ARR). Methods. In-vivo 4D flow MRI was performed in 11 patients after VSARR (47 +/- 18 years, 6 bicuspid aortic valves, 5 trileaflet aortic valves), 16 patients after BIO-ARR (52 +/- 14 years), and 10 healthy controls (47 +/- 16 years). Analysis included three-dimensional blood flow visualization and grading of helix flow in the ascending aorta (AAo) and arch. Peak systolic velocity was quantified in 9 analysis planes in the AAo, aortic arch, and descending aorta. Flow profile uniformity was evaluated in the aortic root and ascending aorta. Results. Peak systolic velocity (2.0 to 2.5m/second) in the aortic root and AAo in both VSARR and BIO-ARR were elevated compared with controls (1.1 to 1.3m/second, p < 0.005). Flow asymmetry in BIO-ARR was increased compared with VSARR, evidenced by more AAo outflow jets (9 of 16 BIO-ARR, 0 of 11 in VSARR). The BIO- ARR exhibited significantly (p < 0.001) increased helix flow in the AAo as a measure of increased flow derangement. Finally, peak systolic velocities were elevated at the aortic root for BIO-ARR (2.5 vs 2.0m/second, p < 0.05) but lower in the distal AAo when compared with VSARR. Conclusions. The VSARR results in improved hemodynamic outcomes when compared with BIO- ARR, as indicated by reduced peak velocities in the aortic root and less helix flow in the AAo by 4D flow MRI. Longitudinal research assessing the clinical impact of these differences in hemodynamic outcomes is warranted. (C) 2015 by The Society of Thoracic Surgeons
引用
收藏
页码:1556 / 1562
页数:7
相关论文
共 50 条
  • [41] Comparison of hemodynamics and root configurations between remodeling and reimplantation methods for valve-sparing aortic root replacement: a pulsatile flow study
    Masahiro Seki
    Takashi Kunihara
    Jyunpei Takada
    Kenichi Sasaki
    Ryo Kumazawa
    Hiroshi Seki
    Saeko Sasuga
    Hirotsugu Fukuda
    Mitsuo Umezu
    Kiyotaka Iwasaki
    Surgery Today, 2023, 53 : 845 - 854
  • [42] Circulating microemboli after composite replacement or valve-sparing aortic root surgery
    Nötzold, A
    Gerriets, T
    Eggers, J
    Kupiske, G
    Seidel, G
    Kaps, M
    Sievers, HH
    THORACIC AND CARDIOVASCULAR SURGEON, 2002, 50 (03): : 141 - 144
  • [43] Asymptomatic pseudoaneurysm 8 years after valve-sparing aortic root replacement
    Osada, Hiroaki
    Kanemitsu, Hideo
    Sakai, Jiro
    Kumagai, Motoyuki
    Yamazaki, Kazuhiro
    Minatoya, Kenji
    JTCVS TECHNIQUES, 2022, 14 : 48 - 49
  • [44] Valve-sparing aortic root replacement after closure of ventricular septal defect
    Kono, Atsunori
    Nomura, Yoshikatsu
    Murakami, Hirohisa
    Sakamoto, Toshihito
    Tanaka, Hiroshi
    Tanaka, Hiroshi
    JTCVS TECHNIQUES, 2024, 28
  • [45] Valve-sparing aortic root replacement after neonatal arterial switch operation
    Narahari, Adishesh K.
    Mehaffey, J. Hunter
    Salerno, Michael
    Battle, Robert
    Ailawadi, Gorav
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (06) : 2146 - 2148
  • [46] Morphology of Sinus of Valsalva After Aortic Valve-Sparing Root Replacement Using Valsalva Graft
    Tadokoro, Naoki
    Inoue, Yosuke
    Minatoya, Kenji
    Matsuda, Hitoshi
    ANNALS OF THORACIC SURGERY, 2020, 109 (01): : E59 - E62
  • [47] From valve-sparing aortic root replacement to aortic root reconstruction: the importance of aortic valve repair
    Laurin, Charles
    Williams, Elbert
    El-Hamamsy, Ismail
    ANNALS OF CARDIOTHORACIC SURGERY, 2023, 12 (04) : 364 - 365
  • [48] Valve-sparing aortic root replacement and aortic valve repair in a patient with acromegaly and aortic root dilatation
    Van Praet, Karel
    Mechanick, Jeffrey I.
    Orozco, Vicente
    Stewart, Allan S.
    RUSSIAN OPEN MEDICAL JOURNAL, 2015, 4 (03)
  • [49] Analysis of aortic root surgery with composite mechanical aortic valve conduit and valve-sparing reconstruction
    Dias, Ricardo Ribeiro
    Vilca Mejia, Omar Asdrubal
    Fiorelli, Alfredo Inacio
    Alberto Pomerantzeff, Pablo Maria
    Dias, Altamiro Ribeiro
    Mady, Charles
    Groppo Stolf, Noedir Antonio
    REVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULAR, 2010, 25 (04): : 491 - 499
  • [50] Aortic Root Replacement with a Stented Bioprosthetic Valved Conduit: Mid-Term Results
    Gatti, Giuseppe
    Dell'Angela, Luca
    Pinamonti, Bruno
    Moncada, Alessandro
    Minati, Alessandro
    Benussi, Bernardo
    Sinagra, Gianfranco
    Pappalardo, Aniello
    JOURNAL OF HEART VALVE DISEASE, 2013, 22 (04): : 500 - 508