Comparison of Hemodynamics After Aortic Root Replacement Using Valve-Sparing or Bioprosthetic Valved Conduit

被引:34
|
作者
Collins, Jeremy D.
Semaan, Edouard
Barker, Alex
McCarthy, Patrick M.
Carr, James C.
Markl, Michael
Malaisrie, S. Chris
机构
[1] Northwestern Univ, Dept Radiol, Feinberg Sch Med, Chicago, IL 60611 USA
[2] Northwestern Univ, Div Cardiac Surg, Feinberg Sch Med, Chicago, IL 60611 USA
[3] Northwestern Univ, McCormick Sch Engn, Dept Biomed Engn, Chicago, IL 60611 USA
来源
ANNALS OF THORACIC SURGERY | 2015年 / 100卷 / 05期
关键词
PHASE-CONTRAST MRI; MAGNETIC-RESONANCE; FLOW PATTERNS; ASCENDING AORTA; MARFAN-SYNDROME; BLOOD-FLOW; SURGERY; GRAFT; ANEURYSM; ENERGY;
D O I
10.1016/j.athoracsur.2015.04.109
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The purpose of this study is to compare aortic hemodynamics and blood flow patterns using in-vivo four-dimensional (4D) flow magnetic resonance imaging (MRI) in patients after valve-sparing aortic root replacement (VSARR) and aortic root replacement with bioprosthetic valves (BIO-ARR). Methods. In-vivo 4D flow MRI was performed in 11 patients after VSARR (47 +/- 18 years, 6 bicuspid aortic valves, 5 trileaflet aortic valves), 16 patients after BIO-ARR (52 +/- 14 years), and 10 healthy controls (47 +/- 16 years). Analysis included three-dimensional blood flow visualization and grading of helix flow in the ascending aorta (AAo) and arch. Peak systolic velocity was quantified in 9 analysis planes in the AAo, aortic arch, and descending aorta. Flow profile uniformity was evaluated in the aortic root and ascending aorta. Results. Peak systolic velocity (2.0 to 2.5m/second) in the aortic root and AAo in both VSARR and BIO-ARR were elevated compared with controls (1.1 to 1.3m/second, p < 0.005). Flow asymmetry in BIO-ARR was increased compared with VSARR, evidenced by more AAo outflow jets (9 of 16 BIO-ARR, 0 of 11 in VSARR). The BIO- ARR exhibited significantly (p < 0.001) increased helix flow in the AAo as a measure of increased flow derangement. Finally, peak systolic velocities were elevated at the aortic root for BIO-ARR (2.5 vs 2.0m/second, p < 0.05) but lower in the distal AAo when compared with VSARR. Conclusions. The VSARR results in improved hemodynamic outcomes when compared with BIO- ARR, as indicated by reduced peak velocities in the aortic root and less helix flow in the AAo by 4D flow MRI. Longitudinal research assessing the clinical impact of these differences in hemodynamic outcomes is warranted. (C) 2015 by The Society of Thoracic Surgeons
引用
收藏
页码:1556 / 1562
页数:7
相关论文
共 50 条
  • [21] Aortic root replacement with a valve-sparing technique for quadricuspid aortic valve
    Yamanaka, Katsuhiro
    Okada, Kenji
    Okita, Yutaka
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 47 (04) : 741 - 743
  • [22] Valve-sparing aortic root replacement for a prolapsing asymmetric valve
    Takahashi, Daisuke
    Shiiya, Norihiko
    Washiyama, Naoki
    Yamashita, Katsushi
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 24 (03) : 464 - 465
  • [23] Valve-Sparing Replacement of the Aortic Root after Repair of Tetralogy of Fallot
    Ootaki, Yoshio
    Kuromaru, Ryuichi
    Ungerleider, Ross M.
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 19 (02) : 170 - 172
  • [24] Valve-sparing root replacement after prior Starr-Edwards aortic valve replacement
    Reade, CC
    Kypson, AP
    Williams, JM
    JOURNAL OF HEART VALVE DISEASE, 2005, 14 (05): : 695 - 696
  • [25] Failures of Valve-sparing Aortic Root Replacement Using the Root Remodeling Technique
    Giebels, Christian
    Fister, Julia-Carolin
    Ehrlich, Tristan
    Federspiel, Jan
    Schaefers, Hans-Joachim
    ANNALS OF THORACIC SURGERY, 2022, 113 (06): : 2000 - 2006
  • [26] The 10 Commandments for Valve-Sparing Aortic Root Replacement
    Samman, Bana
    Mazine, Amine
    Ouzounian, Maral
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2024,
  • [27] Proposed Modification for Valve-Sparing Aortic Root Replacement
    Mahesh, Balakrishnan
    Deville, Claude
    Nashef, Samer
    ANNALS OF THORACIC SURGERY, 2014, 97 (05): : 1811 - 1813
  • [28] Valve-sparing aortic root replacement: a primer for cardiologists
    Mazine, Amine
    Chu, Michael W. A.
    El-Hamamsy, Ismail
    Peterson, Mark D.
    CURRENT OPINION IN CARDIOLOGY, 2022, 37 (02) : 156 - 164
  • [29] Valve-sparing aortic root replacement for Marfan syndrome
    Affleck, DG
    Camillo, C
    Moon, MR
    CHEST, 2003, 124 (04) : 266S - 267S
  • [30] Matched comparison between external aortic root support and valve-sparing root replacement
    Van Hoof, Lucas
    Lamberigts, Marie
    Noe, Dries
    El-Hamamsy, Ismail
    Lansac, Emmanuel
    Kluin, Jolanda
    de Kerchove, Laurent
    Pepper, John
    Treasure, Tom
    Meuris, Bart
    Rega, Filip
    Verbrugghe, Peter
    HEART, 2023, 109 (11) : 832 - 838