Comparison of Hemodynamics After Aortic Root Replacement Using Valve-Sparing or Bioprosthetic Valved Conduit

被引:34
|
作者
Collins, Jeremy D.
Semaan, Edouard
Barker, Alex
McCarthy, Patrick M.
Carr, James C.
Markl, Michael
Malaisrie, S. Chris
机构
[1] Northwestern Univ, Dept Radiol, Feinberg Sch Med, Chicago, IL 60611 USA
[2] Northwestern Univ, Div Cardiac Surg, Feinberg Sch Med, Chicago, IL 60611 USA
[3] Northwestern Univ, McCormick Sch Engn, Dept Biomed Engn, Chicago, IL 60611 USA
来源
ANNALS OF THORACIC SURGERY | 2015年 / 100卷 / 05期
关键词
PHASE-CONTRAST MRI; MAGNETIC-RESONANCE; FLOW PATTERNS; ASCENDING AORTA; MARFAN-SYNDROME; BLOOD-FLOW; SURGERY; GRAFT; ANEURYSM; ENERGY;
D O I
10.1016/j.athoracsur.2015.04.109
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The purpose of this study is to compare aortic hemodynamics and blood flow patterns using in-vivo four-dimensional (4D) flow magnetic resonance imaging (MRI) in patients after valve-sparing aortic root replacement (VSARR) and aortic root replacement with bioprosthetic valves (BIO-ARR). Methods. In-vivo 4D flow MRI was performed in 11 patients after VSARR (47 +/- 18 years, 6 bicuspid aortic valves, 5 trileaflet aortic valves), 16 patients after BIO-ARR (52 +/- 14 years), and 10 healthy controls (47 +/- 16 years). Analysis included three-dimensional blood flow visualization and grading of helix flow in the ascending aorta (AAo) and arch. Peak systolic velocity was quantified in 9 analysis planes in the AAo, aortic arch, and descending aorta. Flow profile uniformity was evaluated in the aortic root and ascending aorta. Results. Peak systolic velocity (2.0 to 2.5m/second) in the aortic root and AAo in both VSARR and BIO-ARR were elevated compared with controls (1.1 to 1.3m/second, p < 0.005). Flow asymmetry in BIO-ARR was increased compared with VSARR, evidenced by more AAo outflow jets (9 of 16 BIO-ARR, 0 of 11 in VSARR). The BIO- ARR exhibited significantly (p < 0.001) increased helix flow in the AAo as a measure of increased flow derangement. Finally, peak systolic velocities were elevated at the aortic root for BIO-ARR (2.5 vs 2.0m/second, p < 0.05) but lower in the distal AAo when compared with VSARR. Conclusions. The VSARR results in improved hemodynamic outcomes when compared with BIO- ARR, as indicated by reduced peak velocities in the aortic root and less helix flow in the AAo by 4D flow MRI. Longitudinal research assessing the clinical impact of these differences in hemodynamic outcomes is warranted. (C) 2015 by The Society of Thoracic Surgeons
引用
收藏
页码:1556 / 1562
页数:7
相关论文
共 50 条
  • [1] Comparison of David V valve-sparing root replacement and bioprosthetic valve conduit for aortic root aneurysm
    DeNino, Walter F.
    Toole, John Matthew
    Rowley, Christopher
    Stroud, Martha R.
    Ikonomidis, John S.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (06): : 2883 - 2887
  • [2] Stentless bioprosthetic aortic valve replacement after valve-sparing aortic root replacement
    Ikonomidis, JS
    Miller, DC
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (04): : 848 - 851
  • [3] Biological solutions to aortic root replacement: valve-sparing versus bioprosthetic conduit
    Gaudino, Mario
    Di Franco, Antonino
    Ohmes, Lucas B.
    Weltert, Luca
    Lau, Christopher
    Gambardella, Ivancarmine
    Salica, Andrea
    Munjal, Monica
    Elsayed, Mohamed
    Girardi, Leonard N.
    De Paulis, Ruggero
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 24 (06) : 855 - 861
  • [4] Valve-sparing Aortic Root Replacement
    Shimizu, Hideyuki
    Yozu, Ryohei
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 17 (04) : 330 - 336
  • [5] Valve-sparing aortic root replacement
    Sin, YK
    Pillai, RG
    JOURNAL OF CARDIAC SURGERY, 2000, 15 (06) : 424 - 427
  • [6] Valve-sparing aortic root replacement
    Koolbergen, David R.
    Manshanden, Johan S. J.
    Bouma, Berto J.
    Blom, Nico A.
    Mulder, Barbara J. M.
    de Mol, Bas A. J. M.
    Hazekamp, Mark G.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 47 (02) : 348 - 354
  • [7] Transcatheter aortic valve replacement after valve-sparing aortic root surgery
    Vendramin, Igor
    Bortolotti, Uberto
    Livi, Ugolino
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (11) : 4434 - 4434
  • [8] Transcatheter aortic valve replacement after valve-sparing aortic root surgery
    Tugulan, Carmen I.
    Bedi, Ryan
    Jacks, Danielle
    Parrino, Eugene P.
    Spindel, Stephen M.
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (06) : 2117 - 2120
  • [9] Comparison of Two Strategies for Aortic Valve-Sparing Root Replacement
    Beckmann, Erik
    Leone, Alessandro
    Martens, Andreas
    Mariani, Carlo
    Krueger, Heike
    Cebotari, Serghei
    Di Bartolomeo, Roberto
    Haverich, Axel
    Shrestha, Malakh Lal
    Pacini, Davide
    ANNALS OF THORACIC SURGERY, 2020, 109 (02): : 505 - 511
  • [10] Aortic Graft Dehiscence After Valve-Sparing Root Replacement
    Uchida, Tetsuro
    Hamasaki, Azumi
    Kuroda, Yoshinori
    Yamashita, Atsushi
    Mizumoto, Masahiro
    Sadahiro, Mitsuaki
    ANNALS OF THORACIC SURGERY, 2019, 108 (03): : E169 - E171