The accuracy and reliability of 3D CT/MRI co-registration in planning epilepsy surgery

被引:44
|
作者
Tao, James X. [1 ]
Hawes-Ebersole, Susan [1 ]
Baldwin, Maria [1 ]
Shah, Sona [1 ]
Erickson, Robert K. [1 ]
Ebersole, John S. [1 ]
机构
[1] Univ Chicago, Dept Neurol & Neurosurg, Adult Epilepsy Ctr, Chicago, IL 60637 USA
关键词
Co-registration; Epilepsy surgery; Subdural electrodes; Temporal lobe epilepsy; Intra-operative digital photography; SUBDURAL ELECTRODES; CT IMAGES; PRESURGICAL EVALUATION; TEMPORAL-LOBE; LOCALIZATION; MRI; COREGISTRATION; RECONSTRUCTION; FUSION;
D O I
10.1016/j.clinph.2009.02.002
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To investigate the accuracy and reliability of 3D CT/MRI co-registration technique for the localization of implanted subdural electrodes in the routine epilepsy presurgical evaluation, in so doing assess its usefulness in planning the tailored resection of epileptic focus. Methods: Four external anatomic fiducial makers were used for co-registration of volumetric pre-implant brain MRI and post-implant head CT using Curry 5.0 software in 19 epilepsy presurgical candidates. The location of subdural electrodes derived from the co-registration was compared to that obtained by intra-operative digital photographs by using gyral/sulcal patterns and cortical vasculature as anatomic markers. Results: The mean localization error was 4.3 +/- 2.5 mm in all 19 patients. However, the mean localization error was 3.1 +/- 1.3 mm in 13 patients with all four reliable fiducial markers; whereas the mean localization error was 6.8 +/- 2.4 mm in 6 patients with two or three reliable fiducial markers. Conclusion: Visualization of subdural electrode positions on a patient's cortex can be accurately performed in the routine clinical setting by 3D CT/MRI co-registration. However, the accuracy of co-registration is dependent upon having reliable surface fiducial markers. In practice, confirmation of location accuracy, such as with intra-operative digital photographs, is necessary for planning of tailored resective surgery. Significance: The combination of 3D CT/MRI co-registration and intra-operative digital photography techniques provides a practical and effective algorithm for the localization and validation of implanted subdural electrodes. (C) 2009 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:748 / 753
页数:6
相关论文
共 50 条
  • [21] Co-registration of FLAIR- and T1-weighted MRI for image guided extended lesionectomy in epilepsy surgery
    Mahvash, M
    König, R
    Urbach, H
    von Oertzen, J
    Meyer, B
    Schaller, C
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1283 - 1283
  • [22] Resection planning in extratemporal epilepsy surgery using 3D multimodality imaging and intraoperative MRI
    Nowell, Mark
    Sparks, Rachel
    Zombori, Gergely
    Miserocchi, Anna
    Rodionov, Roman
    Diehl, Beate
    Wehner, Tim
    White, Mark
    Ourselin, Sebastien
    McEvoy, Andrew
    Duncan, John
    BRITISH JOURNAL OF NEUROSURGERY, 2017, 31 (04) : 468 - 470
  • [23] Combined multimodal co-registration of PET/CT and MRI images increases diagnostic accuracy in squamous cell carcinoma staging
    Stecco, Alessandro
    Ciolfi, Silvio
    Buemi, Francesco
    Cassara, Alessia
    Sacchetti, Gian Mauro
    Brambilla, Marco
    Carriero, Alessandro
    RADIOLOGIA MEDICA, 2016, 121 (06): : 502 - 509
  • [24] Accurate co-registration of CT and SPECT perfusion images for lung radiotherapy planning
    Partridge, M
    Christian, JA
    Flux, G
    McNair, HA
    Cronin, B
    Cook, G
    Courbon, F
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S67 - S67
  • [25] An evaluation of four CT-MRI co-registration techniques for radiotherapy treatment planning of prone rectal cancer patients
    Dean, C. J.
    Sykes, J. R.
    Cooper, R. A.
    Hatfield, P.
    Carey, B.
    Swift, S.
    Bacon, S. E.
    Thwaites, D.
    Sebag-Montefiore, D.
    Morgan, A. M.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1009): : 61 - 68
  • [26] A multicenter evaluation of a new method for co-registration of IVUS and 3D angiograms.
    Houissa, K.
    Cruden, N. L.
    Uren, N.
    Escaned, J.
    Macaya, C.
    Slots, T.
    Carlier, S.
    ACTA CARDIOLOGICA, 2016, 71 (01) : 107 - 107
  • [27] Co-registration of MRI and ultrasound: accuracy of targeting based on radiology-pathology correlation
    Lai, Win Shun
    Zarzour, Jessica G.
    Gordetsky, Jennifer B.
    Rais-Bahrami, Soroush
    TRANSLATIONAL ANDROLOGY AND UROLOGY, 2017, 6 (03) : 406 - 412
  • [28] 3D co-registration algorithm for catheter-based optical coherence tomography
    Post, Anouk L.
    Cernohorsky, Paul
    Pedrigi, Ryan M.
    Streekstra, Geert J.
    D'Hooghe, Julia N. S.
    Annema, Jouke T.
    Strackee, Simon D.
    Krams, Rob
    van Leeuwen, Ton G.
    de Bruin, Daniel M.
    Faber, Dirk J.
    OSA CONTINUUM, 2020, 3 (10) : 2707 - 2721
  • [29] CO-REGISTRATION OF 3D POINT CLOUDS BY USING AN ERRORS-INVARIABLES MODEL
    Aydar, U.
    Altan, M. O.
    Akyilmaz, O.
    Akca, D.
    XXII ISPRS CONGRESS, TECHNICAL COMMISSION V, 2012, 39-B5 : 151 - 155
  • [30] MAGNETOENCEPHALOGRAPHY-ELECTROENCEPHALOGRAPHY CO-REGISTRATION USING 3D GENERALIZED HOUGH TRANSFORM
    Lin, Sheng-Kai
    Lo, Rong-Chin
    Lee, Ren-Guey
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2020, 32 (03):