MAGNETOENCEPHALOGRAPHY-ELECTROENCEPHALOGRAPHY CO-REGISTRATION USING 3D GENERALIZED HOUGH TRANSFORM

被引:0
|
作者
Lin, Sheng-Kai [1 ]
Lo, Rong-Chin [1 ]
Lee, Ren-Guey [1 ]
机构
[1] Natl Taipei Univ Technol, Inst Elect Engn, 1,Sec 3,Zhongxiao E Rd, Taipei 10608, Taiwan
关键词
Magnetoencephalography; electroencephalography; three-dimensional generalized Hough transform; CURVES;
D O I
10.4015/S1016237220500246
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study proposes an advanced co-registration method for an integrated high temporal resolution electroencephalography (EEG) and magnetoencephalography (MEG) data. The MEG has a higher accuracy for source localization techniques and spatial resolution by sensing magnetic fields generated by the entire brain using multichannel superconducting quantum interference devices, whereas EEG can record electrical activities from larger cortical surface to detect epilepsy. However, by integrating the two modality tools, we can accurately localize the epileptic activity compared to other non-invasive modalities. Integrating the two modality tools is challenging and important. This study proposes a new algorithm using an extended three-dimensional generalized Hough transform (3D GHT) to coregister the two modality data. The pre-process steps require the locations of EEG electrodes, MEG sensors, head-shape points of subjects and fiducial landmarks. The conventional GHT algorithm is a well-known method used for identifying or locating two 2D images. This study proposes a new co-registration method that extends the 2D GHT algorithm to a 3D GHT algorithm that can automatically co-register 3D image data. It is important to study the prospective brain source activity in bio-signal analysis. Furthermore, the study examines the registration accuracy evaluation by calculating the root mean square of the Euclidean distance of MEG-EEG co-registration data. Several experimental results are used to show that the proposed method for co-registering the two modality data is accurate and efficient. The results demonstrate that the proposed method is feasible, sufficiently automatic, and fast for investigating brain source images.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] MEG-MRI CO-REGISTRATION USING 3D GENERALIZED HOUGH TRANSFORM
    Lin, Sheng-Kai
    Lo, Rong-Chin
    Lee, Ren-Guey
    [J]. BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2020, 32 (04):
  • [2] AUTOMATIC CO-REGISTRATION OF MEG AND 3D DIGITIZATION USING 3D GENERALIZED HOUGH TRANSFORM
    Lin, Sheng-Kai
    Lo, Rong-Chin
    Lee, Ren-Guey
    [J]. BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2020, 32 (03):
  • [3] MEG and 3D Digitization Co-registration of Head Using 3D Hough Transform
    Lin, Sheng Kai
    Lo, Rong Chin
    [J]. INTERNATIONAL CONFERENCE ON BIOLOGICAL, MEDICAL AND CHEMICAL ENGINEERING (BMCE 2013), 2013, : 653 - 656
  • [4] Automatic 3D Surface Co-Registration Using Keypoint Matching
    Persad, Ravi Ancil
    Armenakis, Costas
    [J]. PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 2017, 83 (02): : 137 - 151
  • [5] Demisting the Hough Transform for 3D Shape Recognition and Registration
    Oliver J. Woodford
    Minh-Tri Pham
    Atsuto Maki
    Frank Perbet
    Björn Stenger
    [J]. International Journal of Computer Vision, 2014, 106 : 332 - 341
  • [6] Demisting the Hough Transform for 3D Shape Recognition and Registration
    Woodford, Oliver J.
    Minh-Tri Pham
    Maki, Atsuto
    Perbet, Frank
    Stenger, Bjoern
    [J]. INTERNATIONAL JOURNAL OF COMPUTER VISION, 2014, 106 (03) : 332 - 341
  • [7] Demisting the Hough Transform for 3D Shape Recognition and Registration
    Woodford, Oliver J.
    Minh-Tri Pham
    Maki, Atsuto
    Perbet, Frank
    Stenger, Bjoern
    [J]. PROCEEDINGS OF THE BRITISH MACHINE VISION CONFERENCE 2011, 2011,
  • [8] Co-registration of Surfaces by 3D Least Squares Matching
    Akca, Devrim
    [J]. PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 2010, 76 (03): : 307 - 318
  • [9] EEG–MRI Co-registration and Sensor Labeling Using a 3D Laser Scanner
    L. Koessler
    T. Cecchin
    O. Caspary
    A. Benhadid
    H. Vespignani
    L. Maillard
    [J]. Annals of Biomedical Engineering, 2011, 39 : 983 - 995
  • [10] CO-REGISTRATION OF 3D POINT CLOUDS BY USING AN ERRORS-INVARIABLES MODEL
    Aydar, U.
    Altan, M. O.
    Akyilmaz, O.
    Akca, D.
    [J]. XXII ISPRS CONGRESS, TECHNICAL COMMISSION V, 2012, 39-B5 : 151 - 155