APMP comparison of activity measurements of I-131 (APMP.RI(II)-K2.I-131)

被引:0
|
作者
Yunoki, Akira
Bignell, Lindsey [1 ]
Mo, Li [1 ]
Joseph, Leena [2 ]
Yuan, Ming-Chen
Park, Tae-Soon [3 ]
Soodprasert, Thongchai
Wurdiyanto, Gatot
机构
[1] ANSTO, Lucas Heights, NSW, Australia
[2] BARC, Bombay, Maharashtra, India
[3] KRISS, Taejon, South Korea
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The international comparison of activity measurements of 131I (APMP.RI(II)-K2.I-131) was carried out within the framework of the Asia-Pacific Metrology Programme (APMP). Seven laboratories took part in the comparison, and five of them undertook absolute measurements. One ampoule containing the same radioactive solution as that used in the APMP comparison was sent to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM) in order to link the APMP comparison to the BIPM.RI(II)-K1.I-131 comparison and to evaluate degrees of equivalence with the key comparison reference value (KCRV).
引用
收藏
页数:9
相关论文
共 50 条
  • [31] 74 MBq radioiodine I-131 does prevent uptake of therapeutic activity of I-131 in residual thyroid tissue
    Medvedec, M
    Pavlinovic, Z
    Dodig, D
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1013 - 1013
  • [32] Update of the BIPM comparison BIPM.RI(II)-K1.I-131 of activity measurements of the radionuclide 131I to include the 2015 results of the BEV (Austria) and the POLATOM (Poland), the 2017 result of the NMISA (South Africa), and to link the CCRI(II)-S6.I-131 comparison
    Michotte C.
    Courte S.
    Nonis M.
    Coulon R.
    Ratel G.
    Maringer F.J.
    Brettner-Messler R.
    Dziel T.
    Listkowska A.
    Van Rooy M.W.V.
    Van Staden M.J.V.
    Lubbe J.
    Zimmerman B.
    Metrologia, 2023, 60 (1 A)
  • [33] National comparison of I-131 solution measurements in Romanian nuclear medicine units
    Sahagia, M
    Razdolescu, AC
    Grigorescu, EL
    Ivan, C
    Luca, A
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 3, 1996, : C497 - C499
  • [34] INTRALYMPHATIC I-131 THERAPY OF SOME MALIGNANT TUMORS RADIOLYMPHOGRAPHY WITH I-131 .2. CLINICAL OBSERVATIONS
    HLINIAKO.I
    SKALSKAV.J
    POLISH REVIEW OF RADIOLOGY AND NUCLEAR MEDICINE, 1971, 35 (01): : 80 - &
  • [35] I-131 TREATMENT OF GRAVES-DISEASE USING MODIFIED EARLY I-131 UPTAKE MEASUREMENTS IN THERAPY DOSE CALCULATIONS
    HAYES, AA
    AKRE, CM
    GORMAN, CA
    JOURNAL OF NUCLEAR MEDICINE, 1990, 31 (04) : 519 - 522
  • [36] BIPM comparison BIPM.RI(II)-K1.Fe-59 of activity measurements of the radionuclide 59Fe for the PTB (Germany), LNE-LNHB (France) and the NMIJ (Japan), and the linked APMP.RI(II)-K2.Fe-59 comparison
    Michotte, C.
    Ratel, G.
    Courte, S.
    Kossert, K.
    Nahle, O.
    Dersch, R.
    Branger, T.
    Bobin, C.
    Yunoki, A.
    Sato, Y.
    METROLOGIA, 2020, 57 (1A)
  • [37] DOSAGE SUGGESTIONS IN I-131 THERAPY FOR BENIGN THYROID-DISEASES, BASED ON KINETIC MEASUREMENTS OF THERAPEUTIC I-131 APPLICATIONS
    STOLL, HP
    OBERHAUSEN, E
    NUKLEARMEDIZIN, 1988, 27 (02) : 52 - 52
  • [38] COMPARISON OF I-123 AND I-131 FOR THYROID UPTAKE MEASUREMENT
    FILIATRAUT, AZ
    TETALMAN, M
    DARE, J
    SCHEU, J
    GRAY, B
    GERDES, S
    INVESTIGATIVE RADIOLOGY, 1976, 11 (05) : 414 - 414
  • [39] COMPARISON OF THE CHARACTERISTICS OF I-131 AND I-123 WITH RESPECT TO DIFFERENTIATING RELATIVE KIDNEY ACTIVITY
    CLARKE, LP
    QADIR, F
    ALSHEIKH, W
    SERAFINI, A
    JOURNAL OF NUCLEAR MEDICINE, 1982, 23 (05) : P93 - P93
  • [40] PERCENTAGE UPTAKE OF TREATMENT ACTIVITY OF I-131 BY THYROID
    SCHOBER, B
    JOURNAL OF NUCLEAR MEDICINE, 1978, 19 (11) : 1268 - 1268