Eicosanoids are a large family that derives from arachidonic acid, i.e., eicosatetraenoic acid. Prominent members include prostaglandins, thromboxane and leukotrienes. They are biologically highly active lipid mediators and play multiple physiological roles. GC-MS/MS has played a pivotal role in the identification and quantification of eicosanoids in biological samples. This technology generated a solid knowledge of their analytical chemistry, biochemistry, physiology and pharmacology. Since about a decade, GC-MS and GC-MS/MS are increasingly displaced by the seemingly more simple, rapid and powerful LC-MS/MS in the area of instrumental analysis of physiological substances, drugs and their metabolites. In this article, we review and discuss LC-MS/MS methods published over the last decade from the perspective of the GC-MS/MS user. Our analysis revealed that the shift from the adult GC-MS/MS to the youthful emerging LC-MS/MS technology in eicosanoid analysis is associated with several important challenges. Known pitfalls and problematic issues discovered by eicosanoid pioneers by using GC-MS/MS are often ignored by LC-MS/MS users. Established reference values and intervals provided by GC-MS-based methods are not considered properly in developing and validating LC-MS/MS methods. Virtually, there is a belief in the unlimited capability of the LC-MS/MS technique in eicosanoid analysis, a thought that simulates analytical certainty. LC-MS/MS users should profit from the plethora of solid knowledge acquired from the use of GC-MS/MS in eicosanoid analysis in basic and clinical research. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:79 / 88
页数:10
相关论文
共 50 条
  • [41] LC-MS and GC-MS based metabolomics platform for cancer research
    Wenyun Lu
    Sisi Zhang
    Xin Teng
    Eugene Melamud
    Mitchell A Lazar
    Eileen White
    Joshua D Rabinowitz
    [J]. Cancer & Metabolism, 2 (Suppl 1)
  • [42] Derivatization of steroids in biological samples for GC-MS and LC-MS analyses
    Marcos, Josep
    Pozo, Oscar J.
    [J]. BIOANALYSIS, 2015, 7 (19) : 2515 - 2536
  • [43] LC-MS and GC-MS based metabolomics platform for cancer research
    Lu, Wenyun
    Zhang, Sisi
    Teng, Xin
    Melamud, Eugene
    Lazar, Mitchell A.
    White, Eileen
    Rabinowitz, Joshua D.
    [J]. CANCER & METABOLISM, 2014, 2
  • [44] LC-MS/MS and GC-MS methods in propofol detection: Evaluation of the two analytical procedures
    Vaiano, Fabio
    Serpelloni, Giovanni
    Focardi, Martina
    Fioravanti, Alessia
    Mari, Francesco
    Bertol, Elisabetta
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2015, 256 : 1 - 6
  • [45] Simultaneous quantification of nicotine salts in e-liquids by LC-MS/MS and GC-MS
    Han, Shulei
    Chen, Huan
    Su, Yue
    Cui, Lili
    Feng, Pengxia
    Fu, Ya'ning
    Tian, Yushan
    Liu, Tong
    Hou, Hongwei
    Hu, Qingyuan
    [J]. ANALYTICAL METHODS, 2022, 14 (42) : 4185 - 4192
  • [46] Identification of the chemical constituents in Cullen corylifolium ethanolic extract by LC-MS/MS and GC-MS
    Wang, Hongzheng
    Chen, Keyu
    Xue, Rui
    Turghun, Chimengul
    Han, Bo
    [J]. NATURAL PRODUCT RESEARCH, 2023, 37 (08) : 1392 - 1396
  • [47] Elucidation of decomposition pathways of linoleic acid hydroperoxide isomers by GC-MS and LC-MS/MS
    Miyazaki, Ruriko
    Kato, Shunji
    Otoki, Yurika
    Rahmania, Halida
    Sakaino, Masayoshi
    Takeuchi, Shigeo
    Sato, Toshiro
    Imagi, Jun
    Nakagawa, Kiyotaka
    [J]. BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2023, 87 (02) : 179 - 190
  • [48] Rapid sample preparation method for LC-MS/MS or GC-MS analysis of acrylamide in various food matrices
    Mastovska, Katerina
    Lehotay, Steven J.
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (19) : 7001 - 7008
  • [49] Urinary amino acid analysis: A comparison of iTRAQ®-LC-MS/MS, GC-MS, and amino acid analyzer
    Kaspar, Hannelore
    Dettmer, Katja
    Chan, Queenie
    Daniels, Scott
    Nimkar, Subodh
    Daviglus, Martha L.
    Stamler, Jeremiah
    Elliott, Paul
    Oefner, Peter J.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (20-21): : 1838 - 1846
  • [50] Analysis of lipid peroxidation products of LDL by LC-MS and GC-MS methods.
    Yin, HY
    Morrow, JD
    Porter, NA
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 223 : U68 - U68