Urinary amino acid analysis: A comparison of iTRAQ®-LC-MS/MS, GC-MS, and amino acid analyzer

被引:134
|
作者
Kaspar, Hannelore [1 ]
Dettmer, Katja [1 ]
Chan, Queenie [2 ]
Daniels, Scott [3 ]
Nimkar, Subodh [4 ]
Daviglus, Martha L. [5 ]
Stamler, Jeremiah [5 ]
Elliott, Paul [2 ]
Oefner, Peter J. [1 ]
机构
[1] Univ Regensburg, Inst Funct Gen, D-93053 Regensburg, Germany
[2] Univ London Imperial Coll Sci Technol & Med, Div Epidemiol Publ Hlth & Primary Care, London, England
[3] Appl Biosyst Inc, Framingham, MA USA
[4] Appl Biosyst Inc, Foster City, CA 94404 USA
[5] Northwestern Univ, Feinberg Sch Med, Dept Prevent Med, Chicago, IL 60611 USA
关键词
Amino acids; Urine; Gas chromatography-mass spectrometry; Liquid chromatography-tandem mass spectrometry; Amino acid analyzer; Precolumn derivatization; Stable isotope dilution; iTRAQ; Propyl chloroformate; TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; BIOLOGICAL-FLUIDS; METABOLISM; DIAGNOSIS; PRESSURE;
D O I
10.1016/j.jchromb.2009.05.019
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ (R) derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ (R) tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ (R)-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27 +/- 5.22, 21.18 +/- 10.94, and 18.34 +/- 14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39 +/- 5.35,6.23 +/- 3.84, and 35.37 +/- 29.42. Both GC-MS and iTRAQ (R)-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1838 / 1846
页数:9
相关论文
共 50 条
  • [1] Analysis of neurosterols by GC-MS and LC-MS/MS
    Griffiths, William J.
    Wang, Yuqin
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (26): : 2778 - 2805
  • [2] Investigation of the changes in volatile composition and amino acid profile of a gala-dinner dish by GC-Ms and LC-MS/MS analyses
    Tabak, Tolgahan
    Yilmaz, Ilkay
    Tekiner, Ismail Hakki
    [J]. INTERNATIONAL JOURNAL OF GASTRONOMY AND FOOD SCIENCE, 2021, 25
  • [3] Targeted amino acid and related amines analysis based on iTRAQ®-LC-MS/MS for discovering potential hepatotoxicity biomarkers
    An, Zhuoling
    Hu, Ting
    Lv, Yali
    Li, Pengfei
    Liu, Lihong
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 178
  • [4] Oxidized and nitrated oleic acid in biological systems: Analysis by GC-MS/MS and LC-MS/MS, and biological significance
    Tsikas, Dimitrios
    Zoerner, Alexander A.
    Jordan, Jens
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR AND CELL BIOLOGY OF LIPIDS, 2011, 1811 (11): : 694 - 705
  • [5] LC-MS/MS AND GC-MS(/MS) BASED STEROIDOMICS
    Wudy, S. A.
    Sanchez-Guijo, A.
    Hartmann, M. F.
    [J]. REPRODUCTION IN DOMESTIC ANIMALS, 2014, 49 : 47 - 47
  • [6] The best MS option: GC-MS and LC-MS
    Sheehan, TL
    [J]. AMERICAN LABORATORY, 2002, 34 (18) : 40 - +
  • [7] Phytochemical analysis in Alternanthera brasiliana by LC-MS/MS and GC-MS
    de Alencar Filho, Jose M. T.
    Teixeira, Hyany A. P.
    Sampaio, Pedrita A.
    Pereira, Emanuella C. V.
    e Amariz, Isabela A.
    Rolim Neto, Pedro J.
    Rolim, Larissa A.
    da Cruz Araujo, Edigenia C.
    [J]. NATURAL PRODUCT RESEARCH, 2020, 34 (03) : 429 - 433
  • [8] Elucidation of decomposition pathways of linoleic acid hydroperoxide isomers by GC-MS and LC-MS/MS
    Miyazaki, Ruriko
    Kato, Shunji
    Otoki, Yurika
    Rahmania, Halida
    Sakaino, Masayoshi
    Takeuchi, Shigeo
    Sato, Toshiro
    Imagi, Jun
    Nakagawa, Kiyotaka
    [J]. BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2023, 87 (02) : 179 - 190
  • [9] Multiresidue analysis of pesticides in moringa pods by GC-MS/MS and LC-MS/MS
    Dutta, Anirban
    Hingmire, Sandip
    Banerjee, Kaushik
    [J]. Journal of AOAC International, 2020, 103 (06): : 1486 - 1497
  • [10] Analysis of eicosanoids by LC-MS/MS and GC-MS/MS: A historical retrospect and a discussion
    Tsikas, Dimitrios
    Zoerner, Alexander A.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 964 : 79 - 88