Urinary amino acid analysis: A comparison of iTRAQ®-LC-MS/MS, GC-MS, and amino acid analyzer

被引:134
|
作者
Kaspar, Hannelore [1 ]
Dettmer, Katja [1 ]
Chan, Queenie [2 ]
Daniels, Scott [3 ]
Nimkar, Subodh [4 ]
Daviglus, Martha L. [5 ]
Stamler, Jeremiah [5 ]
Elliott, Paul [2 ]
Oefner, Peter J. [1 ]
机构
[1] Univ Regensburg, Inst Funct Gen, D-93053 Regensburg, Germany
[2] Univ London Imperial Coll Sci Technol & Med, Div Epidemiol Publ Hlth & Primary Care, London, England
[3] Appl Biosyst Inc, Framingham, MA USA
[4] Appl Biosyst Inc, Foster City, CA 94404 USA
[5] Northwestern Univ, Feinberg Sch Med, Dept Prevent Med, Chicago, IL 60611 USA
关键词
Amino acids; Urine; Gas chromatography-mass spectrometry; Liquid chromatography-tandem mass spectrometry; Amino acid analyzer; Precolumn derivatization; Stable isotope dilution; iTRAQ; Propyl chloroformate; TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; BIOLOGICAL-FLUIDS; METABOLISM; DIAGNOSIS; PRESSURE;
D O I
10.1016/j.jchromb.2009.05.019
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ (R) derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ (R) tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ (R)-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27 +/- 5.22, 21.18 +/- 10.94, and 18.34 +/- 14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39 +/- 5.35,6.23 +/- 3.84, and 35.37 +/- 29.42. Both GC-MS and iTRAQ (R)-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1838 / 1846
页数:9
相关论文
共 50 条
  • [21] Direct LC-MS/MS and indirect GC-MS/MS methods for measuring urinary bisphenol A concentrations are comparable
    Ashley-Martin, Jillian
    Gaudreau, Eric
    Dumas, Pierre
    Liang, Chun Lei
    Logvin, Agata
    Belanger, Patrick
    Provencher, Gilles
    Gagne, Sebastien
    Foster, Warren
    Lanphear, Bruce
    Arbuckle, Tye E.
    [J]. ENVIRONMENT INTERNATIONAL, 2021, 157
  • [22] Comparison of Amino Acid Concentrations in Plasma and Dried Blood Spot Samples Using LC-MS/MS
    Aslan, Ozgur
    Erkan, Revsa Evin Canpolat
    [J]. IRANIAN JOURNAL OF PEDIATRICS, 2022, 32 (03)
  • [23] Electronic cigarette solution and vapor analysis with GC-MS and LC-MS
    Lazernik, Michael
    Cole, Preston
    Jones, Martin
    Shamp, Brian
    Dormedy, Derek
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [24] GC-MS/MS and LC-MS/MS analysis followed by risk ranking of mepiquat and pyrethroids in coffee
    Radulovic, Jelena
    Lucic, Milica
    Onjia, Antonije
    [J]. JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2024, 129
  • [25] GC-MS analysis of diaminopimelic acid stereoisomers and amino acid enantiomers in rumen bacteria
    Schieber, A
    Brückner, H
    Ling, JR
    [J]. BIOMEDICAL CHROMATOGRAPHY, 1999, 13 (01) : 46 - 50
  • [26] Finding of pesticides in fashionable fruit juices by LC-MS/MS and GC-MS/MS
    Tran, Kevin
    Eide, David
    Nickols, Susan M.
    Cromer, Michele R.
    Sabaa-Srur, Armando
    Smith, Robert E.
    [J]. FOOD CHEMISTRY, 2012, 134 (04) : 2398 - 2405
  • [27] Amino Acid Analysis of Peptides Using Isobaric-Tagged Isotope Dilution LC-MS/MS
    Woolfitt, Adrian R.
    Solano, Maria I.
    Williams, Tracie L.
    Pirkle, James L.
    Barr, John R.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (10) : 3979 - 3985
  • [28] A GC-MS method for determination of amino acid uptake by plants
    Persson, J
    Näsholm, T
    [J]. PHYSIOLOGIA PLANTARUM, 2001, 113 (03) : 352 - 358
  • [29] A Tale of Two Drug Testing Technologies: GC-MS and LC-MS/MS
    Mikel, Charles
    Pesce, Amadeo
    West, Cameron
    [J]. PAIN PHYSICIAN, 2010, 13 (01) : 91 - 92
  • [30] Residue analysis of 500 high priority pesticides: Better by GC-MS or LC-MS/MS?
    Alder, Lutz
    Greulich, Kerstin
    Kempe, Guenther
    Vieth, Barbel
    [J]. MASS SPECTROMETRY REVIEWS, 2006, 25 (06) : 838 - 865