On the RF Heating of Coronary Stents at 7.0 Tesla MRI

被引:56
|
作者
Winter, Lukas [1 ]
Oberacker, Eva [1 ]
Oezerdem, Celal [1 ]
Ji, Yiyi [1 ]
von Knobelsdorff-Brenkenhoff, Florian [1 ,2 ,3 ]
Weidemann, Gerd [4 ,5 ]
Ittermann, Bernd [4 ,5 ]
Seifert, Frank [4 ,5 ]
Niendorf, Thoralf [1 ,2 ,3 ]
机构
[1] Max Delbrueck Ctr Mol Med, BUFF, D-13125 Berlin, Germany
[2] Charite Med Fac, ECRC, Berlin, Germany
[3] Max Delbrueck Ctr Mol Med, D-13125 Berlin, Germany
[4] PTB, Braunschweig, Germany
[5] PTB, Berlin, Germany
关键词
ultrahigh field MR; RF heating; coronary stents; specific absorption rate; RF power deposition; MAGNETIC-RESONANCE; ELECTRICAL-CONDUCTIVITY; PARALLEL TRANSMISSION; CARDIAC MRI; 7; T; COIL; COMPATIBILITY; MULTICENTER; IMPLANTS; DESIGN;
D O I
10.1002/mrm.25483
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Examine radiofrequency (RF) induced heating of coronary stents at 7.0 Tesla (T) to derive an analytical approach which supports RF heating assessment of arbitrary stent geometries and RF coils. Methods: Simulations are performed to detail electromagnetic fields (EMF), local specific absorption rates (SAR) and temperature changes. For validation E-field measurements and RF heating experiments are conducted. To progress to clinical setups RF coils tailored for cardiac MRI at 7.0T and coronary stents are incorporated into EMF simulations using a human voxel model. Results: Our simulations of coronary stents at 297 MHz were confirmed by E-field and temperature measurements. An analytical solution which describes SAR((1g tissue voxel)) induced by an arbitrary coronary stent interfering with E-fields generated by an arbitrary RF coil was derived. The analytical approach yielded a conservative estimation of induced SAR(1g tissue voxel) maxima without the need for integrating the stent into EMF simulations of the human voxel model. Conclusion: The proposed analytical approach can be applied for any patient, coronary stent type, RF coil configuration and RF transmission regime. The generalized approach is of value for RF heating assessment of other passive electrically conductive implants and provides a novel design criterion for RF coils. (C) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:999 / 1010
页数:12
相关论文
共 50 条
  • [1] Detailing Radio Frequency Heating Induced by Coronary Stents: A 7.0 Tesla Magnetic Resonance Study
    Santoro, Davide
    Winter, Lukas
    Mueller, Alexander
    Vogt, Julia
    Renz, Wolfgang
    Oezerdem, Celal
    Graessl, Andreas
    Tkachenko, Valeriy
    Schulz-Menger, Jeanette
    Niendorf, Thoralf
    PLOS ONE, 2012, 7 (11):
  • [2] MRI of the knee at 7.0 Tesla
    Kraff, Oliver
    Theysohn, J. M.
    Maderwald, S.
    Saylor, C.
    Ladd, S. C.
    Ladd, M. E.
    Barkhausen, J.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (12): : 1231 - 1235
  • [3] 7.0 Tesla MRI The "Field of Dreams"?
    Weigele, John B.
    ACADEMIC RADIOLOGY, 2010, 17 (04) : 407 - 409
  • [4] 7.0 Tesla MRI tractography in patients with trigeminal neuralgia
    Moon, Hyeong Cheol
    You, Soon-Tae
    Baek, Hyeon Man
    Jeon, Young Jai
    Park, Chan-A
    Cheong, Jei Jun
    Lee, Youn Joo
    Park, Young Seok
    MAGNETIC RESONANCE IMAGING, 2018, 54 : 265 - 270
  • [5] Effect of 7.0 Tesla MRI on upper eyelid implants
    Schrom, Thomas
    Thelen, Ariane
    Asbach, Patrick
    Bauknecht, Hans-Christian
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2006, 22 (06): : 480 - 482
  • [6] Tissue Border Enhancement by inversion recovery MRI at 7.0 Tesla
    Costagli, Mauro
    Kelley, Douglas A. C.
    Symms, Mark R.
    Biagi, Laura
    Stara, Riccardo
    Maggioni, Eleonora
    Tiberi, Gianluigi
    Barba, Carmen
    Guerrini, Renzo
    Cosottini, Mirco
    Tosetti, Michela
    NEURORADIOLOGY, 2014, 56 (07) : 517 - 523
  • [7] Feasibility of high-resolution pituitary MRI at 7.0 tesla
    de Rotte, Alexandra A. J.
    van der Kolk, Anja G.
    Rutgers, Dik
    Zelissen, Pierre M. J.
    Visser, Fredy
    Luijten, Peter R.
    Hendrikse, Jeroen
    EUROPEAN RADIOLOGY, 2014, 24 (08) : 2005 - 2011
  • [8] Feasibility of high-resolution pituitary MRI at 7.0 tesla
    Alexandra A. J. de Rotte
    Anja G. van der Kolk
    Dik Rutgers
    Pierre M. J. Zelissen
    Fredy Visser
    Peter R. Luijten
    Jeroen Hendrikse
    European Radiology, 2014, 24 : 2005 - 2011
  • [9] Tissue Border Enhancement by inversion recovery MRI at 7.0 Tesla
    Mauro Costagli
    Douglas A. C. Kelley
    Mark R. Symms
    Laura Biagi
    Riccardo Stara
    Eleonora Maggioni
    Gianluigi Tiberi
    Carmen Barba
    Renzo Guerrini
    Mirco Cosottini
    Michela Tosetti
    Neuroradiology, 2014, 56 : 517 - 523
  • [10] Comparison of in-vivo and in-vitro MRI RF Heating for Orthopedic Implant at 3 Tesla
    Guo, Ran
    Zheng, Jianfeng
    Chen, Ji
    2017 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2017, : 1019 - 1020